Sierra Monitor Corporation HRG010-W, HRG015-W Model label, Location of hazard warning label

Page 12

HRX-OM-J049-A

Chapter 1 Safety Instructions

1.3.3Location of hazard warning label

zRecognize where the hazard warning labels are attached.

zThe user is not allowed to reposition the labels. If the label is replaced due to being peeled off or worn out, keep the previous position.

Warning label for

high Left

Front

Warning label on the

front panel

 

Fig. 1-3 Location of Hazard Warning Label

 

1.4 Model label

Check the model no. described on the label.

Front

Fig. 1-4 Location of Model Label

1.4 Model label

HRG010-W HRG015-W

1-6

1st edition : Aug. 2006

Rev. A: May. 2007

Image 12
Contents Water-refrigerated Thermo cooler To the Customers Table of Contents Error Message and Troubleshooting Chapter Unit MaintenanceStartup and Shutdown Chapter DocumentsTOC-3 TOC-4 Safety Instructions Before Using this UnitLevel of risk Definitions of Serious injury and Minor injury„ Serious injury „ Minor injury Symbols „ High temperature hazards Hazard Warning LabelClassification of risks „ High voltage hazardsType of hazard warning labels Model label Location of hazard warning labelSafety Measures Safety Precautions„ For system transportation, installation and removal Protective equipment„ For handling circulating fluid „ For system operationEmergency Measures Thermo Cooler OFFRecovery of refrigerant and compressor oil Disposition of WasteMaterial Safety Data Sheet Msds Circulating fluid disposalSystem disposal Safety Instructions Appearance and Each Section AppearanceName of Each Section 1 HRG010-W2 HRG015-W Name of Each Section HRG015-WControl panel Name FunctionTransport and Installation TransportTransporting with forklift and unit lifting Forklift Insertion Position and Unit LiftingTransporting with caster „ HRG010-W-A / HRG015-W-A caster-mounted optionInstallation Installation conditionsInstallation location Installation location and maintenance work area Recommended Installation LocationInstallation „ Procedure for InstallationHRG010-W-A / HRG015-W-A Caster-mounted Option Electrical wiring „ Power supply cable and Gfci breakerHRG010-W HRG015-W „ How to conduct wiring Removal of Front Panel„ Electrical wiring diagram HRG015-WSpecifications 11 Communication Cable Wiring„ How to install piping Piping„ Pipe diameter „ Recommended piping installation Name Size HRG010-W HRG015-WName Qty Supply of circulating fluid Open the supply valve laid with pipesReinstallation of unit „ Disconnection of power supply cableStartup and Shutdown Pre-checkPower supply Setting of circulating fluid temperaturePreparation for startup „ TS switch pump manual operation switch Additional water supplyUnit Startup and Shutdown Starting the unitStopping the unit Check at startup „ Bypass valve„ Bypass relieving valve piping set Error Message Troubleshooting Error MessageTroubleshooting See 5.3 Alarm Reset for error recoveryAlarm Reset Alarm Lamp OFF „ Error checkUndo the screws 6 pcs. to remove the front panel „ When the alarm lamp goes out by performing steps 1. to Location of Reset Switch RS Yellow ButtonRecovery from Power Failure Power Lamp on „ Power error checkUndo the screws 6 pcs. to remove the front panel Switch off the earth leakage breaker once Unit Maintenance Control of Water QualitySubstances Facility water Circulating fluid spec Spec Inspection and Cleaning Daily inspection Inspection itemInspection method „ Replacement of circulating fluid „ Cleaning of facility waterQuarterly inspection Biannual inspectionCheck during wintertime „ Antifreeze of circulating fluid„ Antifreeze function automatic pump operation Consumables Long-term StoragePart number Qty Remarks Standard Specifications DocumentsHRG010-W HRG015-W Optional Specifications „ Caster„ Gfci breaker „ CommunicationOutline Dimensions 2 HRG010-W-A, HRG015-W-AElectric Circuit 1 HRG010-W, HRG015-W2 HRG010-W-BC, HRG015-W-BC Electric Circuit HRG010-W-BC, HRG015-W-BCFlow Chart „ HRG010-W, HRG015-WThermo Cooler HRG010-W / WRG015-W Daily Inspection Sheet IN/OUTProduct Warranty