Sierra Monitor Corporation operation manual HRG010-W-A / HRG015-W-A Caster-mounted Option

Page 30

HRX-OM-J049-A

Chapter 3 Transport and Installation

„HRG010-W-A / HRG015-W-A (caster-mounted option)

As to the HRG010-W-A or HRG015-W-A (caster-mounted option), the adjusters should be lowered to secure the system after installation.

Lower the adjusters to secure the system.

Caster w/ adjuster

Fig. 3-6 HRG010-W-A / HRG015-W-A (Caster-mounted Option)

3.2 Installation

HRG010-W HRG015-W

3-8

1st edition : Aug. 2006

Rev. A: May. 2007

Image 30
Contents Water-refrigerated Thermo cooler To the Customers Table of Contents Startup and Shutdown Error Message and TroubleshootingChapter Unit Maintenance Chapter DocumentsTOC-3 TOC-4 Safety Instructions Before Using this Unit„ Serious injury Level of riskDefinitions of Serious injury and Minor injury „ Minor injurySymbols Classification of risks „ High temperature hazardsHazard Warning Label „ High voltage hazardsType of hazard warning labels Model label Location of hazard warning labelSafety Measures Safety Precautions„ For handling circulating fluid „ For system transportation, installation and removalProtective equipment „ For system operationEmergency Measures Thermo Cooler OFFRecovery of refrigerant and compressor oil Disposition of WasteMaterial Safety Data Sheet Msds Circulating fluid disposalSystem disposal Safety Instructions Appearance and Each Section AppearanceName of Each Section 1 HRG010-W2 HRG015-W Name of Each Section HRG015-WControl panel Name FunctionTransport and Installation TransportTransporting with forklift and unit lifting Forklift Insertion Position and Unit LiftingTransporting with caster „ HRG010-W-A / HRG015-W-A caster-mounted optionInstallation Installation conditions Installation location Installation location and maintenance work area Recommended Installation LocationInstallation „ Procedure for InstallationHRG010-W-A / HRG015-W-A Caster-mounted Option Electrical wiring „ Power supply cable and Gfci breakerHRG010-W HRG015-W „ How to conduct wiring Removal of Front Panel„ Electrical wiring diagram HRG015-WSpecifications 11 Communication Cable Wiring„ How to install piping Piping„ Pipe diameter „ Recommended piping installation Name Size HRG010-W HRG015-WName Qty Supply of circulating fluid Open the supply valve laid with pipesReinstallation of unit „ Disconnection of power supply cableStartup and Shutdown Pre-checkPower supply Setting of circulating fluid temperaturePreparation for startup „ TS switch pump manual operation switch Additional water supplyUnit Startup and Shutdown Starting the unitStopping the unit Check at startup „ Bypass valve„ Bypass relieving valve piping set Error Message Troubleshooting Error MessageTroubleshooting See 5.3 Alarm Reset for error recoveryAlarm Reset Alarm Lamp OFF „ Error checkUndo the screws 6 pcs. to remove the front panel „ When the alarm lamp goes out by performing steps 1. to Location of Reset Switch RS Yellow ButtonRecovery from Power Failure Power Lamp on „ Power error checkUndo the screws 6 pcs. to remove the front panel Switch off the earth leakage breaker once Unit Maintenance Control of Water QualitySubstances Facility water Circulating fluid spec Spec Inspection and Cleaning Daily inspection Inspection itemInspection method Quarterly inspection „ Replacement of circulating fluid„ Cleaning of facility water Biannual inspectionCheck during wintertime „ Antifreeze of circulating fluid„ Antifreeze function automatic pump operation Consumables Long-term StoragePart number Qty Remarks Standard Specifications DocumentsHRG010-W HRG015-W „ Gfci breaker Optional Specifications„ Caster „ CommunicationOutline Dimensions 2 HRG010-W-A, HRG015-W-AElectric Circuit 1 HRG010-W, HRG015-W2 HRG010-W-BC, HRG015-W-BC Electric Circuit HRG010-W-BC, HRG015-W-BCFlow Chart „ HRG010-W, HRG015-WThermo Cooler HRG010-W / WRG015-W Daily Inspection Sheet IN/OUTProduct Warranty