Sierra Monitor Corporation HRG015-W, HRG010-W Alarm Reset Alarm Lamp OFF, „ Error check

Page 47

HRX-OM-J049-A

Chapter 5 Error Message and Troubleshooting

5.3 Alarm Reset (Alarm Lamp OFF)

„Error check

1. Check the alarm number currently activated, and eliminate the error cause (see Table 5-2). Adjust the unit usage and service condition.

or

[POWER] LED

[ALARM2] LED

or

[RUN] LED

[ALARM3] LED

or

[ALARM1] LED

Fig. 5-2 Alarm Lamps (ON)

[ALARM1] ON

Installation error

[ALARM2] ON

Circulating fluid circuit error

[ALARM3] ON

Refrigerating circuit error

HRG010-W HRG015-W

5.3 Alarm Reset (Alarm Lamp OFF)

1st edition : Aug. 2006

5-3

Rev. A: May. 2007

Image 47
Contents Water-refrigerated Thermo cooler To the Customers Table of Contents Chapter Documents Error Message and TroubleshootingChapter Unit Maintenance Startup and ShutdownTOC-3 TOC-4 Before Using this Unit Safety Instructions„ Minor injury Level of riskDefinitions of Serious injury and Minor injury „ Serious injurySymbols „ High voltage hazards „ High temperature hazardsHazard Warning Label Classification of risksType of hazard warning labels Location of hazard warning label Model labelSafety Precautions Safety Measures„ For system operation „ For system transportation, installation and removalProtective equipment „ For handling circulating fluidThermo Cooler OFF Emergency MeasuresDisposition of Waste Recovery of refrigerant and compressor oilSystem disposal Material Safety Data Sheet MsdsCirculating fluid disposal Safety Instructions Appearance Appearance and Each Section1 HRG010-W Name of Each SectionName of Each Section HRG015-W 2 HRG015-WName Function Control panelTransport Transport and InstallationForklift Insertion Position and Unit Lifting Transporting with forklift and unit lifting„ HRG010-W-A / HRG015-W-A caster-mounted option Transporting with casterInstallation conditions InstallationInstallation location Recommended Installation Location Installation location and maintenance work area„ Procedure for Installation InstallationHRG010-W-A / HRG015-W-A Caster-mounted Option HRG010-W HRG015-W Electrical wiring„ Power supply cable and Gfci breaker Removal of Front Panel „ How to conduct wiringHRG015-W „ Electrical wiring diagram11 Communication Cable Wiring Specifications„ Pipe diameter „ How to install pipingPiping Name Qty „ Recommended piping installationName Size HRG010-W HRG015-W Open the supply valve laid with pipes Supply of circulating fluid„ Disconnection of power supply cable Reinstallation of unitPre-check Startup and ShutdownPreparation for startup Power supplySetting of circulating fluid temperature Additional water supply „ TS switch pump manual operation switchStopping the unit Unit Startup and ShutdownStarting the unit „ Bypass valve Check at startup „ Bypass relieving valve piping set Error Message Error Message TroubleshootingSee 5.3 Alarm Reset for error recovery Troubleshooting„ Error check Alarm Reset Alarm Lamp OFFUndo the screws 6 pcs. to remove the front panel Location of Reset Switch RS Yellow Button „ When the alarm lamp goes out by performing steps 1. to„ Power error check Recovery from Power Failure Power Lamp onUndo the screws 6 pcs. to remove the front panel Switch off the earth leakage breaker once Substances Facility water Circulating fluid spec Spec Unit MaintenanceControl of Water Quality Inspection and Cleaning Inspection method Daily inspectionInspection item Biannual inspection „ Replacement of circulating fluid„ Cleaning of facility water Quarterly inspection„ Antifreeze function automatic pump operation Check during wintertime„ Antifreeze of circulating fluid Part number Qty Remarks ConsumablesLong-term Storage Documents Standard SpecificationsHRG010-W HRG015-W „ Communication Optional Specifications„ Caster „ Gfci breaker2 HRG010-W-A, HRG015-W-A Outline Dimensions1 HRG010-W, HRG015-W Electric CircuitElectric Circuit HRG010-W-BC, HRG015-W-BC 2 HRG010-W-BC, HRG015-W-BC„ HRG010-W, HRG015-W Flow ChartIN/OUT Thermo Cooler HRG010-W / WRG015-W Daily Inspection SheetProduct Warranty