Chapter 3 Transport and Installation

3.1.2Transporting with caster

„HRG010-W-A / HRG015-W-A (caster-mounted option)

This unit is heavy, which requires assistance for this work. Exercise caution and look out for sloped surfaces including ramps.

Do not grab piping or panel handles when transporting the sytem with the casters.

Potential damage to piping and panels may occur if disregarded.

1. Push the corners of this unit with the adjusters uplifted.

The unit becomes disengaged so that it can be transported with casters.

Turn 360°.

Turn 360°.

Front

Caster w/ adjuster

 

Uplift the adjuster.

Handle

Pipe port

Fig. 3-3 Caster-mounted Option

HRG010-W HRG015-W

3.1 Transport

1st edition : Aug. 2006

3-3

Rev. A: May. 2007

Image 25
Contents Water-refrigerated Thermo cooler To the Customers Table of Contents Chapter Unit Maintenance Error Message and TroubleshootingStartup and Shutdown Chapter DocumentsTOC-3 TOC-4 Before Using this Unit Safety InstructionsDefinitions of Serious injury and Minor injury Level of risk„ Serious injury „ Minor injurySymbols Hazard Warning Label „ High temperature hazardsClassification of risks „ High voltage hazardsType of hazard warning labels Location of hazard warning label Model labelSafety Precautions Safety MeasuresProtective equipment „ For system transportation, installation and removal„ For handling circulating fluid „ For system operationThermo Cooler OFF Emergency MeasuresDisposition of Waste Recovery of refrigerant and compressor oilCirculating fluid disposal Material Safety Data Sheet MsdsSystem disposal Safety Instructions Appearance Appearance and Each Section1 HRG010-W Name of Each SectionName of Each Section HRG015-W 2 HRG015-W Name Function Control panelTransport Transport and InstallationForklift Insertion Position and Unit Lifting Transporting with forklift and unit lifting„ HRG010-W-A / HRG015-W-A caster-mounted option Transporting with casterInstallation conditions InstallationInstallation location Recommended Installation Location Installation location and maintenance work area„ Procedure for Installation InstallationHRG010-W-A / HRG015-W-A Caster-mounted Option „ Power supply cable and Gfci breaker Electrical wiringHRG010-W HRG015-W Removal of Front Panel „ How to conduct wiringHRG015-W „ Electrical wiring diagram11 Communication Cable Wiring SpecificationsPiping „ How to install piping„ Pipe diameter Name Size HRG010-W HRG015-W „ Recommended piping installationName Qty Open the supply valve laid with pipes Supply of circulating fluid„ Disconnection of power supply cable Reinstallation of unitPre-check Startup and ShutdownSetting of circulating fluid temperature Power supplyPreparation for startup Additional water supply „ TS switch pump manual operation switchStarting the unit Unit Startup and ShutdownStopping the unit „ Bypass valve Check at startup„ Bypass relieving valve piping set Error Message Error Message TroubleshootingSee 5.3 Alarm Reset for error recovery Troubleshooting„ Error check Alarm Reset Alarm Lamp OFFUndo the screws 6 pcs. to remove the front panel Location of Reset Switch RS Yellow Button „ When the alarm lamp goes out by performing steps 1. to„ Power error check Recovery from Power Failure Power Lamp onUndo the screws 6 pcs. to remove the front panel Switch off the earth leakage breaker once Control of Water Quality Unit MaintenanceSubstances Facility water Circulating fluid spec Spec Inspection and Cleaning Inspection item Daily inspectionInspection method „ Cleaning of facility water „ Replacement of circulating fluidQuarterly inspection Biannual inspection„ Antifreeze of circulating fluid Check during wintertime„ Antifreeze function automatic pump operation Long-term Storage ConsumablesPart number Qty Remarks Documents Standard SpecificationsHRG010-W HRG015-W „ Caster Optional Specifications„ Gfci breaker „ Communication2 HRG010-W-A, HRG015-W-A Outline Dimensions1 HRG010-W, HRG015-W Electric CircuitElectric Circuit HRG010-W-BC, HRG015-W-BC 2 HRG010-W-BC, HRG015-W-BC„ HRG010-W, HRG015-W Flow ChartIN/OUT Thermo Cooler HRG010-W / WRG015-W Daily Inspection SheetProduct Warranty