3. WIRE THE COLLECTOR RING TO THE SWEEP

A.Attach one(1) 1" liquid-tight flex conduit coupling to each end of the 1" x 48" liquid-tight flex conduit.

B.Feed the nine (9) stranded wires from the collector ring through the 1" conduit coupling and 1" x 48" liquid-tight flex conduit assembly.

C.Attach the 1" x 48" liquid-tight flex conduit assembly to the pivot tube using the 1" conduit coupling.

1" flex conduit coupling

pivot tube

1" conduit coupling

1" x 48" flex conduit

D.Feed the nine (9) stranded wires from the collector ring through one of the holes in the right junction box.

E.Connect the 1" x 48" liquid-tight flex conduit assembly to the junction box using the 1" liquid- tight flex conduit coupling.

PNEG-970S2 Hopper w/ Collector Ring

25

Image 25
Contents PNEG-970 Series II Sweep Hopper With Collector RingCatalog No. Slip Ring Serial No Date of Purchase Table of Contents Safety Safety Guidelines Read and Understand Manual Safety InstructionsRotating Flight Operate Unload Equipment SafelyElectric Shock Hazard Install & Operate Electrical Equipment ProperlyPrepare for Emergencies Eye Protection Gloves Steel Toe Boots Respirator Hard HatDecal a DecalsRotating Flighting Operator Qualifications Product Information Capacities and SpecificationsGeneral information Slip Ring Information Specifications & ListingsAssembly Assemble the Crossbrace Assembly Assembly Wire the Collector Ring Wire the Collector Ring Assemble the Crossbrace to the Hopper Assemble the Crossbrace to the Hopper Assemble the Crossbrace to the Sweep Assemble the Crossbrace to the Sweep Wire the Collector Ring to the Sweep Wire the Collector Ring to the Sweep Preform Pre-Start Checks Start-UpMaintain the Hopper MaintenanceCollector Ring Maintenance Catalog No. Slip Ring Serial No Date of Purchase Problem Possible Cause Solution Parts 12 & 16 Hopper Components X R D Warranty Box 1004 E. IL. St Assumption IL 217