Hearth and Home Technologies VRT-GY-B-CE 1Listing and Code Approvals, Appliance Certification

Page 4

1Listing and Code Approvals

A. Appliance Certification

MODEL

VRTIKL-CE

LABORATORY

Gastec Certification B.V.

TYPE

Gas Stove

STANDARD

EN 613:2001

DIRECTIVE

CAD90/396/EEC

These instructions are only valid if the following country symbol is on the gas stove. If this symbol is not present on the gas stove, it is necessary to refer to the technical instructions which will provide the necessary information concerning the modification of the gas stove to the conditions of use for the country.

C. Non-Combustible Materials

Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C, shall be considered non-combustible materials.

D. Combustible Materials

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other materials that can ignite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

B. Glass Specifications

This gas stove is equipped with 5mm ceramic glass behind the curved glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

WARNING

Do NOT use this gas stove if any part has been under water. Immediately call a qualified service technician to inspect the gas stove and to replace any part of the control system and any gas control which has been under water.

4

Heat & Glo • VRTIKL-CE7031-292 Rev E • 12/07

Image 4
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Test Lab Report No Manufactured Date Serial No Model NameTable of Contents 1Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsGetting Started Design & Installation ConsiderationsInspect Appliance & Components 3Appliance Location and Clearances Selecting Appliance LocationClearances to Combustibles 15.2 25.7 30.8 137.2 91.4 78.1 33.7 39.4Optional Stone Surround Installed 10.2 78.1 91.44Termination Locations Flue Termination Minimum ClearancesAlcove Applications Gas stoveFlue Information Flue ComponentsUse of Elbows Measuring StandardsFlueing Diagrams For Natural, Propane and Butane GasesNatural Gas One 90 0 Elbow System Natural Gas Two 90 0 Elbows System Min H1 Max H1 + H2 Max Natural Gas Two 900 Elbows System V1 Min Max Natural Gas Three 90 0 Elbows System Horizontal Termination StepSlim Line Wall Thimble Before YOU BeginFIG. B Minimum Clearance Vertical Termination Balance Flue PipeSecure Flashing with NON-HARDENING Sealant Roofing Nails Vertical Flue Restrictor Twist-lock the flue cap and sealGas Pressure Requirements Gas Connection Gas InformationCheck for GAS Leaks 7Electrical Information Ignition System WiringShock Risk Appliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Leveling and Bolting Down the ApplianceTop to Rear Flue Conversion AccessoriesOn TOP of Appliance Installing the Baffle On Back of AppliancePositioning the Logs Placing Mineral WoolCap and Barrel Fastener System Operating Instructions Before Lighting ApplianceLighting the Appliance Do not Connect 240 VAC to the Control ValveInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Maintenance TasksSymptom Possible Causes Corrective Actions TroubleshootingElectronic Ignition System Reference Materials Appliance Dimension Diagram47.9 104.5 103.5 40.3 18.1 76.2 73.3 86.7 Appliance Dimension with Stone Surround Diagram 75.3 62.0 76.8 42.8 86.7 112.6Flue Components Diagram SL-09D SL-12/17D SL-24D SL-36D SL-48DComponents Flue Components ListTermination Kits Service Parts Log Set AssemblyDescription Serial # Part Number P2B/B2P-VRT-CEValve Assembly REM-DLX-CE Heat & GLO Limited 10 Year Warranty Warranty PolicyYour Records for Model Contact Information