A. Maintenance Tasks

Inspect

 

Maintenance Tasks

Doors

1.

Inspect for scratches, dents or other damage and repair as necessary.

 

2.

Verify no obstructions to air flow.

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

2.

Inspect glass for scratches and nicks that can lead to breakage when exposed to heat.

 

3.

Confirm there is no damage to glass or glass frame, Replace as necessary.

 

4.

Verify that latches engage properly and glass attachment components are intact and operat-

 

ing properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be

 

removed.

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

2.

Replace gas stove if firebox has been perforated.

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

necessary.

 

3.

Replace ember material with new 1.5 cm pieces. Do not block ports or obstruct lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting and other flame problems.

 

6.

Inspect orifice for soot, dirt or corrosion.

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

9.

Inspect thermocouple sensor rod for soot, corrosion and deterioration. Clean with emery

 

cloth or replace as required.

 

10. Verify millivolt output. Replace as necessary.

Flueing

1.

Inspect flueing for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

Remote Control

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

Heat & Glo • VRTIKL-CE7031-292 Rev E • 12/07

33

Image 33
Contents What to do if you smell gas Do not Discard this ManualDo Discardnot Serial No Model Name Test Lab Report No Manufactured DateTable of Contents Appliance Certification 1Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsDesign & Installation Considerations Getting StartedInspect Appliance & Components Selecting Appliance Location 3Appliance Location and ClearancesClearances to Combustibles 15.2 25.7 30.8 137.2 91.4 78.1 33.7 39.410.2 78.1 91.4 Optional Stone Surround InstalledFlue Termination Minimum Clearances 4Termination LocationsGas stove Alcove ApplicationsFlue Components Flue InformationUse of Elbows Measuring StandardsFor Natural, Propane and Butane Gases Flueing DiagramsNatural Gas One 90 0 Elbow System Natural Gas Two 90 0 Elbows System Min H1 Max H1 + H2 Max Natural Gas Two 900 Elbows System V1 Min Max Natural Gas Three 90 0 Elbows System Step Horizontal TerminationBefore YOU Begin Slim Line Wall ThimbleFIG. B Minimum Clearance Balance Flue Pipe Vertical TerminationSecure Flashing with NON-HARDENING Sealant Roofing Nails Twist-lock the flue cap and seal Vertical Flue RestrictorGas Information Gas Pressure Requirements Gas ConnectionCheck for GAS Leaks Ignition System Wiring 7Electrical InformationShock Risk Remove Shipping Materials Appliance SetupUnbolting Appliance from the Pallet Leveling and Bolting Down the ApplianceAccessories Top to Rear Flue ConversionOn TOP of Appliance On Back of Appliance Installing the BafflePlacing Mineral Wool Positioning the LogsCap and Barrel Fastener System Before Lighting Appliance Operating InstructionsDo not Connect 240 VAC to the Control Valve Lighting the ApplianceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit After servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Maintenance TasksTroubleshooting Symptom Possible Causes Corrective ActionsElectronic Ignition System Appliance Dimension Diagram Reference Materials47.9 104.5 103.5 40.3 18.1 76.2 73.3 86.7 75.3 62.0 76.8 42.8 86.7 112.6 Appliance Dimension with Stone Surround DiagramSL-09D SL-12/17D SL-24D SL-36D SL-48D Flue Components DiagramFlue Components List ComponentsTermination Kits Log Set Assembly Service PartsP2B/B2P-VRT-CE Description Serial # Part NumberValve Assembly REM-DLX-CE Warranty Policy Heat & GLO Limited 10 Year WarrantyContact Information Your Records for Model