10 Maintaining and Servicing Appliance

Although the frequency of your gas stove servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an gas stove check-up at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to gas stove.

Ensure gas stove is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Obstructions of termination cap.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Clean:

Glass

Air passageways, grilles,

control compartment

• Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

WARNING

Inspect external flue cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation. Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off gas stove after 3-4 hours of operation and ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate gas stove for additional 12 hours.

Refer to maintenance instructions.

32

Heat & Glo • VRTIKL-CE7031-292 Rev E • 12/07

Image 32
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Test Lab Report No Manufactured Date Serial No Model NameTable of Contents 1Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsInspect Appliance & Components Design & Installation ConsiderationsGetting Started 3Appliance Location and Clearances Selecting Appliance LocationClearances to Combustibles 15.2 25.7 30.8 137.2 91.4 78.1 33.7 39.4Optional Stone Surround Installed 10.2 78.1 91.44Termination Locations Flue Termination Minimum ClearancesAlcove Applications Gas stoveFlue Information Flue ComponentsUse of Elbows Measuring StandardsFlueing Diagrams For Natural, Propane and Butane GasesNatural Gas One 90 0 Elbow System Natural Gas Two 90 0 Elbows System Min H1 Max H1 + H2 Max Natural Gas Two 900 Elbows System V1 Min Max Natural Gas Three 90 0 Elbows System Horizontal Termination StepSlim Line Wall Thimble Before YOU BeginFIG. B Minimum Clearance Vertical Termination Balance Flue PipeSecure Flashing with NON-HARDENING Sealant Roofing Nails Vertical Flue Restrictor Twist-lock the flue cap and sealCheck for GAS Leaks Gas InformationGas Pressure Requirements Gas Connection Shock Risk Ignition System Wiring7Electrical Information Appliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Leveling and Bolting Down the ApplianceOn TOP of Appliance AccessoriesTop to Rear Flue Conversion Installing the Baffle On Back of AppliancePositioning the Logs Placing Mineral WoolCap and Barrel Fastener System Operating Instructions Before Lighting ApplianceLighting the Appliance Do not Connect 240 VAC to the Control ValveAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Maintenance TasksElectronic Ignition System TroubleshootingSymptom Possible Causes Corrective Actions 47.9 104.5 103.5 40.3 18.1 76.2 73.3 86.7 Appliance Dimension DiagramReference Materials Appliance Dimension with Stone Surround Diagram 75.3 62.0 76.8 42.8 86.7 112.6Flue Components Diagram SL-09D SL-12/17D SL-24D SL-36D SL-48DTermination Kits Flue Components ListComponents Service Parts Log Set AssemblyDescription Serial # Part Number P2B/B2P-VRT-CEValve Assembly REM-DLX-CE Heat & GLO Limited 10 Year Warranty Warranty PolicyYour Records for Model Contact Information