Bertazzoni X)486GPIRBI, X)486GPIRX, X)486GPIRVI, (A manual Installation Requirements, Electrical, Gas

Page 12

INSTALLING THE ANTI‐TIP Stability DEVICE

The anti‐tip bracket shipped with the range must be properly secured to the rear wall as shown in the picture below.

The height of the bracket from the floor must be determined after the range legs have been adjusted to the desired height and after the range has been levelled.

Measure the distance from the floor to the bottom of the anti‐tip bracket receptacle on the back of the appliance.

Position the two anti‐tip brackets on the wall at the desired height plus 1/8" (0.32 cm). The brackets must be placed at 2”5/16 (6,0 cm) from the side of the range. The distance between the two bracket is 43”1/4 (109,8 cm).

Secure the brackets to the wall with appropriate hardware.

Slide the range against the wall until the brackets are fully inserted into their receptacles on the back of the range.

INSTALLATION REQUIREMENTS

ELECTRICAL

Aproperly grounded and horizontally‐mounted electrical receptacle Type NEMA 14‐50R should be installed no higher than 3" (7.6 cm) above the floor, no less than 2” (5 cm) and no more than 8” (20,3 cm) from the right side (facing product); refer to ELECTRICAL CONNECTION section pag. 13.

Check all local code requirements.

GAS

An agency‐approved, properly‐sized manual shut‐ off valve should be installed no higher than 3" (7.6 cm) above the floor and no less than 2” (5 cm) and no more than 8” (20.3 cm) from the left side (facing product).

To connect gas between shut‐off valve and regulator, use agency‐approved, properly sized flexible or rigid pipe. Check all local code requirements.

12

Image 12
Contents Models A,X486GPIRX From the desk of the President Table of Contents Page Warranty and Service Customer ServiceReplacement Parts Important Safety Information What to do if YOU Smell GASPage Product Specifications Auxiliary 3400 BTU/hBefore Installation Type of GASInstalling the Legs Installing the Worktop FrontguardInstalling the Backguard Installation Requirements ElectricalGAS Installation Adjacent to Kitchen Cabinets Exhaust Hood InstallationElectrical Connection Left OvenPage Electrical Grounding Electrical Shock HazardLocation of Appliance Plates Wiring Diagram Right Oven + Griddle Do not USE AN Open Flame When Checking For Leaks GAS ConnectionManual SHUT‐OFF Valve Flexible ConnectionsPressure Regulator GAS Conversion Surface BurnersMinimum Flame Adjustment GAS Burners Data Tables Installation Checklist Final PreparationRoom Ventilation Symbols Surface Burner LayoutSurface Cooking X486GPIRX,BI,CR,GI,RO,VI,VE,BL,NESurface Burner Operation Thermocouple Safety Valve Electric IgnitionManual Ignition Using the Electric Griddle Tips for Using Pans CorrectlySeasoning the Griddle Oven Cooking Left Oven Griddle cooking recommendationsOven Racks Oven Function SelectorUsing the Oven Bake ConvectionBAKE/CONVECTION/TURBO Rack PositionsSlow Cooking and LOW Temperature Uses of the Oven WarmingProofing Baking RecommendationsDehydrate FruitBroil / Convection Broil Tips for BroilingBroiling and Roasting Recommendations BeefElectric Oven Maintaining Your Range Door LockCleaning Your Range Do not clean the range when hotTroubleshooting Guide Oven Problem Possible Causes AND/OR RemedyLocation of Appliance Tags Important Appliance Information Italy Spare Parts List Oven Door Hinge Cast Iron PAN Support 2 Burner Flask Carter Page Page