GAS CONNECTION
All gas connections must comply with national and local codes. The gas supply line (service) must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" NPT inlet (see drawing below for details of gas connection). On all pipe joints use appropriate sealant resistant to gas.
This range can be used with Natural or LP/Propane gas. The range is shipped from the factory for use with natural gas.
For LP/propane household installation, the appliance must be converted by the dealer, by a factory‐trained professional or by a qualified licensed plumber or gas service company.
Gas conversion is important for safe and effective use of the appliance. It is the responsibility of the dealer and the owner of the range to perform the appropriate gas conversion following the directions of the manufacturer.
THE GAS CONVERSION PROCEDURE IS DESCRIBED IN THIS MANUAL AND IN THE PACKAGE CONTAINING THE CONVERSION NOZZLES SHIPPED WITH EVERY RANGE.
Please provide the service person with this manual before work is started on the range.
WARNING!
DO NOT USE AN OPEN FLAME WHEN CHECKING
FOR LEAKS!
Leak testing of the appliance shall be conducted according to the manufacturer's instructions. Before placing the oven into operation, always check for leaks with soapy water solution or other acceptable method.
MANUAL SHUT‐OFF VALVE
THIS VALVE IS NOT SHIPPED WITH THE
APPLIANCE AND MUST BE SUPPLIED BY THE
INSTALLER.
The manual shut‐off valve must be installed in the gas service line between the gas hook‐up on the wall and the appliance inlet, in a position where it can be reached quickly in the event of an emergency.
In Massachusetts: A 'T' handle type manual gas valve must be installed in the gas supply line to this appliance.
FLEXIBLE CONNECTIONS
In case of installation with flexible couplings and/or quick‐disconnect fittings, the installer must use a heavy‐duty, AGA design‐certified commercial flexible connector of at least 1/2" (1.3 cm) ID NPT (with suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69 standards.
In Massachusetts: The unit must be installed with a 36" (3‐foot) long flexible gas connector.
In Canada: use CAN 1‐6.10‐88 metal connectors for gas appliances and CAN 1‐6.9 M79 quick disconnect device for use with gas fuel.
PRESSURE TEST‐POINT STOPPER VALVE
To avoid gas leaks, the pressure test‐point stopper valve and gasket supplied with the range must be installed on the gas fitting at the back of the range according to the diagram below.
19