SEZ SERIES COUNTERTOP STEAMERS | TROUBLESHOOTING |
Figure 16
Water Solenoid Check
1. DISCONNECT POWER AT CIRCUIT
BREAKER.
2. Remove rear cover.
3. Disconnect water solenoid lead wires from wires B60 and B61.
4. Place test leads into water solenoid lead wires as shown.
5. Resistance should be approximately 800 ohms. Replace if necessary.
6.Disconnect water inlet subassembly from float control box at the compression fitting
closest to the box.
7. Apply of water pressure (approximately 15 psi) to water inlet. Water should not leak out of the compression fitting. If necessary, replace solenoid.
8. Reassemble water inlet, reconnect solenoid lead wires, and reconnect power to unit. When power is turned on, the solenoid should “click.” If no click is heard, test for 200 to 240 volts on wires B60 and B61 within four minutes of turning on power switch. If 200 to 240 volts is present and the solenoid does not click, replace solenoid.
TROUBLESHOOTING
OPERATOR’S MANUAL 1183437 | PAGE 33 |