SEZ SERIES COUNTERTOP STEAMERS | TROUBLESHOOTING |
Figure 8
Heating Element Resistance Check (at Contactor)
C
B
A
Contactor (top view)
1.DISCONNECT POWER AT CIRCUIT BREAKER.
2.Remove control panel.
3.DO NOT REMOVE HEATING ELEMENT LEAD WIRES FOR THIS TEST.
4.Place test leads between terminals A and C on left side of contactor.
5.Check the resistance and compare to the allowable range in the following table:
|
|
|
|
| Model SEZ/3 |
|
| Model SEZ/5 |
|
|
| ||
| Voltage |
|
| Allowable Resistance (Ohms) | Allowable Resistance (Ohms) |
|
| ||||||
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
| |||||||||
| 208 |
| 10 | to 12 | 14 | to 16 | 5 to 6 | 8 to 10 | 11 | to 13 | 4 to 5 |
|
|
| 220 |
| 12 | to 13 | 15 | to 18 | 6 to 7 | 9 to 11 | 13 | to 15 | 5 to 6 |
|
|
| 240 |
| 14 | to 16 | 18 | to 21 | 7 to 9 | 11 to 13 | 15 | to 17 | 6 to 7 |
|
|
| 480 |
| 55 | to 64 | 73 | to 85 | 29 to 34 | 45 to 52 | 60 | to 70 | 24 to 28 |
|
|
6. For | |||||||||||||
C similarly. |
|
|
|
|
|
|
|
|
|