Shindaiwa DG1000MI manual Checking Fuel, Condition

Page 29

8.3.2Condition

Check for any damage on the fan belt. Replace if necessary.

<Caution>

￿Refer to the User’s manual for Engine for adjusting and replacing of the fan belt.

8.4Checking Fuel

Caution

:Fire

￿Always wipe any drip of Diesel fuel or oil. Do not use this equipment when a leak is found. Repair the equipment before use.

Check for the fuel level in the tank. Add if necessary.

<Caution>

￿Use Diesel fuel, ASTM D975 No.2-D in the event ambient temperature reaches down to –5.

￿Always use the Diesel fuel strainer

￿Fill the fuel tank slightly less than the FULL tank,

￿Fuel requirements:

NOTICE: The fuel injection pump, injector or other parts of the fuel system and engine can be damaged if you use any fuel or fuel additive other than those specifically recommended by Isuzu.

Such damage is not our responsibility, and is not covered by the Warranty. To help avoid fuel system or engine damage, please heed the following:

￿Some service stations mix used engine oil with diesel fuel. Some manufacturers of large diesel engines allow this; however, for your diesel engine, do not use the diesel fuel which has been contaminated with engine oil. Besides causing engine damage, such fuel can also affect emission control. Before using any diesel fuel, check with the service station operator to see if the fuel has been mixed with engine oil.

￿Do not use any fuel additive. At the time this manual was printed, no other fuel additive was recommended. (See your authorized dealer to find out if this has changed.)

The engine is designed to use either Number 1-D or No. 2-D diesel fuel. However, for better fuel economy,

use No. 2-D diesel fuel whenever possible. At temperatures less than –7 C (20 F), No.2-D fuel may pose

operating problems (see “Cold Weather Operation” which follows). At colder temperatures, use No.1-D

fuel (if available) or use a “winterized” Number 2-D (a blend of No. 1-D and No. 2-D). This blended fuel is

usually called No. 2-D also, but can be used in colder temperatures than No.2-D fuel which has not been

“winterized”. Check with the service station operator to be sure you can get the properly blended fuel. Note

that diesel fuel may foam during a fill-up. This can cause the automatic pump nozzle to shut off even

though your tank is not full.

- 29 -

Image 29
Contents DG1000MI Introduction Suffocation from exhaust fume Safety GuidelinesElectrical Shock InjuriesExplosion Injuries to eyes and skinFire BurnsInjuries Location of Warning labels Specification Matrix SpecificationsExternal view Use PartsAmbient Condition Control panel Monitor Display EquipmentEngine Oil Monitoring Lamp for oil pressure low Injuries Water Temperature Gauge Battery Charge Monitoring Lamp charge lampGauges Hour Meter built into the TachometerGenerator Gauges Fuel GaugeAmp Meter Frequency MeterEmergency Stop button Switch Starter SwitchPanel Light / Pilot Lamp Thermal Relay Amp Meter Changeover SwitchEarth Leakage Relay Unit Voltage Regulator and Throttle LeverFuel Line Changeover Valve 3-way valve Using fuel from built-in fuel tank< > Transportation Transport and InstallationLifting Equipment TransportationSelecting Cable InstallationConnection Electrical damages For 1-Phase Load1 Connecting CableLoad Connection Terminal Plate 3-Phase For 3-Phase Load 2 1-Phase Output Terminals & Receptacles For 1-Phase Load2Grounding Work Earth Leakage Relay and GroundingOperation Check Electrical Shock Earth leakage breaker relay has activated Initialization and pre-checkElectrical Shock Injuries Fire BurnsEngine Oil Capacity Checking Engine OilSelecting proper engine oil Checking Coolant reservoir tank / Adding coolant Checking Coolant/waterChecking Radiator / Adding water Tension Checking Fan BeltCoolant Capacity Condition Checking FuelChecking Fuel, Engine Oil, and Water leakage Checking BatteryReplacing the battery Initializing / preparation OperationFrequency Adjust Screw Damages to the property 200/400 Voltage Changeover Dual Voltage SystemDuring operation Refer to 7-2. Connecting cableStopping the Generator Protection FeaturesFeature List During Operation section Connecting to External Fuel TankMaintenance Generator side Engine SideReplace, refer to 8-1 Checking Engine Oil 10.1 Oil ChangeCleaning / Changing Air Filter Element Draining Water from Water Separator Cleaning / Changing Fuel FilterClean gauze filter in engine feed pump Clean gauze filter in water separatorIsuzu Part No 8970631550 Draining Water from Fuel Tank Long-term Storage Storage ProceduresStacking Troubleshooting Ask our distributor to repair Page Generator Wiring Diagram Engine Wiring Diagram

DG1000MI specifications

The Shindaiwa DG1000MI is a remarkable model in the world of portable generators, designed to deliver reliable power for both commercial and residential applications. Understanding its main features, technologies, and characteristics is vital for anyone considering a dependable power solution.

One of the most prominent features of the DG1000MI is its compact and lightweight design. Weighing in at approximately 66 pounds, it is easy to transport to various job sites, outdoor events, or even within your own backyard. Despite its size, the generator boasts a significant power output of up to 1000 watts, making it suitable for powering essential appliances, tools, and equipment.

This model is equipped with a powerful 4-stroke engine that ensures efficient fuel consumption while producing minimal emissions. This is particularly important for environmentally conscious users looking to reduce their carbon footprint. The DG1000MI operates quietly, which is beneficial in settings where noise regulations are in place.

An innovative feature of the DG1000MI is its advanced inverter technology. This ensures stable and clean power output, making it ideal for sensitive electronics such as laptops, smartphones, and other devices. The inverter technology regulates the voltage and frequency, providing a consistent power supply that reduces the risk of damage to valuable equipment.

The DG1000MI also offers extended run times, thanks to its efficient fuel management system. With a tank capacity of 1.6 gallons, users can expect 8 to 10 hours of operation on a single tank, depending on the load. This extended run time is a fantastic advantage for users who need consistent power over long durations without frequent refueling.

Maintenance is simplified with the DG1000MI, designed with user friendliness in mind. It features an easy-access oil fill, a large air filter, and a straightforward starting mechanism. This ensures that routine checks and servicing can be performed with minimal hassle.

Finally, Shindaiwa stands by the durability and reliability of the DG1000MI, which is built with robust materials to withstand the rigors of outdoor use. The generator is engineered to perform under various conditions, making it a trusted choice for those who require dependable power in any situation.

In conclusion, the Shindaiwa DG1000MI is an exceptional portable generator that combines efficiency, ease of use, and advanced technology. It is an ideal choice for anyone seeking a versatile and reliable power solution.