10.6 Clean gauze filter in water separator

Clean

Every 500 hours

AIR

RING NUTEXTRACTION PLUG

GAUZE FILTER

Loosen the lever and then loosen the air

extraction plug.

 

 

 

Turn the ring nut counter-clockwise

to remove the cup and the gauze filter after the

fuel inside does not come out from the lever.

Wash the gauze filter in Diesel fuel and reinstall the unit in the reverse order.

 

 

Tightening Torque

 

 

 

 

 

 

 

 

 

 

 

 

Ring Nut

 

15Nm{1.5kgfm}

 

 

 

 

 

 

 

Air Extraction Plug

 

10Nm{1.0kgfm}

 

 

 

 

 

 

 

<Caution>

￿Clean the filter more frequently as gauze filter is clogged in shorter period when using the fuel from the fuel drum than other fuel source.

￿Put a tray under the lever in order to catch spilled fuel when loosing the lever.

￿Extract the air in fuel line after gauze filter washing finishes.

(Refer to 9-3. During operation.)

￿Ensure that there is no fuel leakage after reinstallation.

10.7 Clean gauze filter in engine feed pump

 

 

 

Clean

 

Every 500 hours

 

 

 

 

 

 

 

 

 

 

 

 

Remove eyebolts.

 

 

 

EYEBOLT(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove gauze filter in eyebolts.

 

Wash gauze filters in Diesel fuel and reinstall

 

 

in the reverse order

 

 

 

 

 

 

 

Eyebolt tightening torque

 

44Nm{4.5gfm}

 

 

 

 

 

 

 

 

 

- 43 -

 

 

 

 

 

 

 

 

 

 

 

EYEBOLT(1)

JOINTPIPE

FEED PUMP

Image 43
Contents DG1000MI Introduction Injuries Safety GuidelinesSuffocation from exhaust fume Electrical ShockBurns Injuries to eyes and skinExplosion FireInjuries Location of Warning labels Specification Matrix SpecificationsAmbient Condition Use PartsExternal view Control panel Monitor Display EquipmentEngine Oil Monitoring Lamp for oil pressure low Injuries Hour Meter built into the Tachometer Battery Charge Monitoring Lamp charge lampWater Temperature Gauge GaugesFrequency Meter Fuel GaugeGenerator Gauges Amp MeterPanel Light / Pilot Lamp Switch Starter SwitchEmergency Stop button Voltage Regulator and Throttle Lever Amp Meter Changeover SwitchThermal Relay Earth Leakage Relay UnitFuel Line Changeover Valve 3-way valve Using fuel from built-in fuel tank< > Transportation Transport and InstallationTransportation Lifting EquipmentConnection InstallationSelecting Cable Electrical damages Load Connection Terminal Plate 3-Phase For 3-Phase Load Connecting CableFor 1-Phase Load1 2 1-Phase Output Terminals & Receptacles For 1-Phase Load2Grounding Work Earth Leakage Relay and GroundingOperation Check Electrical Shock Fire Burns Initialization and pre-checkEarth leakage breaker relay has activated Electrical Shock InjuriesSelecting proper engine oil Checking Engine OilEngine Oil Capacity Checking Radiator / Adding water Checking Coolant/waterChecking Coolant reservoir tank / Adding coolant Coolant Capacity Checking Fan BeltTension Condition Checking FuelChecking Fuel, Engine Oil, and Water leakage Checking BatteryReplacing the battery Initializing / preparation OperationFrequency Adjust Screw Damages to the property 200/400 Voltage Changeover Dual Voltage SystemDuring operation Refer to 7-2. Connecting cableFeature List Protection FeaturesStopping the Generator During Operation section Connecting to External Fuel TankMaintenance Generator side Engine Side Replace, refer to 8-1 Checking Engine Oil 10.1 Oil ChangeCleaning / Changing Air Filter Element Draining Water from Water Separator Cleaning / Changing Fuel FilterClean gauze filter in engine feed pump Clean gauze filter in water separatorIsuzu Part No 8970631550 Draining Water from Fuel Tank Long-term Storage Storage ProceduresStacking Troubleshooting Ask our distributor to repair Page Generator Wiring Diagram Engine Wiring Diagram