10.6 Clean gauze filter in water separator
Clean
Every 500 hours
AIR
RING NUTEXTRACTION PLUG
GAUZE FILTER
① | Loosen the lever and then loosen the air | ||||
extraction plug. |
|
|
| ||
Turn the ring nut | |||||
to remove the cup and the gauze filter after the | |||||
fuel inside does not come out from the lever. | |||||
Wash the gauze filter in Diesel fuel and reinstall the unit in the reverse order. | |||||
| ③ |
| Tightening Torque |
| |
|
|
|
| ||
|
|
|
|
|
|
| ② | Ring Nut |
| 15Nm{1.5kgfm} |
|
|
|
|
|
| |
| Air Extraction Plug |
| 10Nm{1.0kgfm} |
| |
|
|
|
|
|
|
<Caution>
Clean the filter more frequently as gauze filter is clogged in shorter period when using the fuel from the fuel drum than other fuel source.
Put a tray under the lever in order to catch spilled fuel when loosing the lever.
Extract the air in fuel line after gauze filter washing finishes.
(Refer to
Ensure that there is no fuel leakage after reinstallation.
10.7 Clean gauze filter in engine feed pump
|
|
| Clean |
| Every 500 hours |
|
|
|
|
|
|
|
|
|
|
|
|
① | Remove eyebolts. |
|
|
| EYEBOLT(2) | |||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
② | Remove gauze filter in eyebolts. |
| ||||||
Wash gauze filters in Diesel fuel and reinstall |
| |||||||
③ |
| |||||||
in the reverse order |
| |||||||
|
|
| ||||||
|
|
| Eyebolt tightening torque |
| 44Nm{4.5gfm} | |||
|
|
|
| |||||
|
|
|
|
| - 43 - |
|
|
|
|
|
|
|
|
|
|
|
EYEBOLT(1)
JOINTPIPE
FEED PUMP