Shindaiwa DG1000MI manual

Page 50

Overheated

 

1.

Engine thermostat is defective

1.

Ask our distributor to repair

 

 

2.

Water temp sensor is defective

2.

Ask our distributor to repair

 

 

3.

Water temp meter is defective

3.

Ask our distributor to repair

 

 

4.

Fan belt tension is weak

4.

Check/Adjust fan belt

 

 

5.

Coolant is insufficient

5.

Check/Supply coolant

 

 

6.

Radiator core is clogged

6.

Clean radiator core

Black smoke comes out from

1.

Air filter element is clogged

1.

Check/Change air filter

muffler

 

 

 

 

element

 

 

2.

Fuel injection nozzle is defective

2.

Ask our distributor to repair

 

 

3.

Improper fuel is used

3.

Change to clean fuel

White smoke comes out from

1. Too much or too little oil to cylinder

1.

Ask our distributor to repair

muffler

 

2. Water is interfused in fuel line

2.

Drain water in water separator,

 

 

 

 

 

fuel filter or fuel tank

 

 

3.

Fuel injection nozzle is defective

3.

Ask our distributor to repair

 

 

4.

Coolant temperature is too low

4.

Warm-up driving is needed

 

 

5.

Engine thermostat is defective

5.

Ask our distributor to repair

Pointer (hand) does not move in

1. Voltage meter is defective

1.

Ask our distributor to repair

voltage meter

 

2. AVR is defective

2.

Ask our distributor to repair

 

 

3.

Disconnected circuit, loose

3.

Ask our distributor to repair

 

 

 

terminal or departed

 

 

 

 

4.

Initial exciter is defective

4.

Ask our distributor to repair

 

 

5.

Alternator is defective

5.

Ask our distributor to repair

Pointer (hand) does not goes up

1. Voltage meter is defective

1.

Ask our distributor to repair

to the rated voltage

 

2. AVR is defective

2.

Ask our distributor to repair

 

 

3.

Voltage regulator dial is defective

3.

Ask our distributor to repair

 

 

4.

Frequency is low

4.

Ask our distributor to repair

 

 

5.

Frequency selector switch is set

5.

Set the switch correct

 

 

 

wrong

 

 

Pointer exceeds

the rated

1. Voltage meter is defective

1.

Ask our distributor to repair

voltage

 

2. AVR is defective

2.

Ask our distributor to repair

The voltage drops

drastically

1.

AVR is defective

1.

Ask our distributor to repair

when connecting to load

2.

Unbalanced loads sharing to

2.

Balance the loads sharing to

 

 

 

each terminal

 

each terminal

 

 

3.

Wrong frequency is used

3.

Set the switch to the load

 

 

 

 

 

frequency

 

 

4.

Loads total exceeds the rated

4.

Decrease the loads to meet the

 

 

 

current

 

rated output

 

 

5.

Frequency selector switch is set

5.

Set the selector switch correct

 

 

 

wrong

 

 

Cannot turn the breaker to ON

1. The breaker positions at between

1.

Once turning the lever to OFF,

 

 

 

ON and OFF

 

turn it to ON

 

 

2.

Short circuit on the load

2.

Check the load circuit

 

 

3.

Earth Leakage Relay activates

3.

Repair the leaked point

 

 

4.

The thermal relay activates

4.

Reset the thermal relay

 

 

 

- 50 -

 

 

Image 50
Contents DG1000MI Introduction Electrical Shock Safety GuidelinesSuffocation from exhaust fume InjuriesFire Injuries to eyes and skinExplosion BurnsInjuries Location of Warning labels Specifications Specification MatrixExternal view Use PartsAmbient Condition Control panel Equipment Monitor DisplayEngine Oil Monitoring Lamp for oil pressure low Injuries Gauges Battery Charge Monitoring Lamp charge lampWater Temperature Gauge Hour Meter built into the TachometerAmp Meter Fuel GaugeGenerator Gauges Frequency MeterEmergency Stop button Switch Starter SwitchPanel Light / Pilot Lamp Earth Leakage Relay Unit Amp Meter Changeover SwitchThermal Relay Voltage Regulator and Throttle LeverUsing fuel from built-in fuel tank Fuel Line Changeover Valve 3-way valve< > Lifting Equipment Transport and InstallationTransportation TransportationSelecting Cable InstallationConnection Electrical damages For 1-Phase Load1 Connecting CableLoad Connection Terminal Plate 3-Phase For 3-Phase Load For 1-Phase Load2 2 1-Phase Output Terminals & ReceptaclesEarth Leakage Relay and Grounding Grounding WorkOperation Check Electrical Shock Electrical Shock Injuries Initialization and pre-checkEarth leakage breaker relay has activated Fire BurnsEngine Oil Capacity Checking Engine OilSelecting proper engine oil Checking Coolant reservoir tank / Adding coolant Checking Coolant/waterChecking Radiator / Adding water Tension Checking Fan BeltCoolant Capacity Checking Fuel ConditionChecking Battery Checking Fuel, Engine Oil, and Water leakageReplacing the battery Operation Initializing / preparationFrequency Adjust Screw 200/400 Voltage Changeover Dual Voltage System Damages to the propertyRefer to 7-2. Connecting cable During operationStopping the Generator Protection FeaturesFeature List Connecting to External Fuel Tank During Operation sectionMaintenance Engine Side Generator side10.1 Oil Change Replace, refer to 8-1 Checking Engine OilCleaning / Changing Air Filter Element Cleaning / Changing Fuel Filter Draining Water from Water SeparatorClean gauze filter in water separator Clean gauze filter in engine feed pumpIsuzu Part No 8970631550 Draining Water from Fuel Tank Storage Procedures Long-term StorageStacking Troubleshooting Ask our distributor to repair Page Generator Wiring Diagram Engine Wiring Diagram

DG1000MI specifications

The Shindaiwa DG1000MI is a remarkable model in the world of portable generators, designed to deliver reliable power for both commercial and residential applications. Understanding its main features, technologies, and characteristics is vital for anyone considering a dependable power solution.

One of the most prominent features of the DG1000MI is its compact and lightweight design. Weighing in at approximately 66 pounds, it is easy to transport to various job sites, outdoor events, or even within your own backyard. Despite its size, the generator boasts a significant power output of up to 1000 watts, making it suitable for powering essential appliances, tools, and equipment.

This model is equipped with a powerful 4-stroke engine that ensures efficient fuel consumption while producing minimal emissions. This is particularly important for environmentally conscious users looking to reduce their carbon footprint. The DG1000MI operates quietly, which is beneficial in settings where noise regulations are in place.

An innovative feature of the DG1000MI is its advanced inverter technology. This ensures stable and clean power output, making it ideal for sensitive electronics such as laptops, smartphones, and other devices. The inverter technology regulates the voltage and frequency, providing a consistent power supply that reduces the risk of damage to valuable equipment.

The DG1000MI also offers extended run times, thanks to its efficient fuel management system. With a tank capacity of 1.6 gallons, users can expect 8 to 10 hours of operation on a single tank, depending on the load. This extended run time is a fantastic advantage for users who need consistent power over long durations without frequent refueling.

Maintenance is simplified with the DG1000MI, designed with user friendliness in mind. It features an easy-access oil fill, a large air filter, and a straightforward starting mechanism. This ensures that routine checks and servicing can be performed with minimal hassle.

Finally, Shindaiwa stands by the durability and reliability of the DG1000MI, which is built with robust materials to withstand the rigors of outdoor use. The generator is engineered to perform under various conditions, making it a trusted choice for those who require dependable power in any situation.

In conclusion, the Shindaiwa DG1000MI is an exceptional portable generator that combines efficiency, ease of use, and advanced technology. It is an ideal choice for anyone seeking a versatile and reliable power solution.