Shindaiwa DG1000MI Safety Guidelines, Suffocation from exhaust fume, Electrical Shock, Injuries

Page 3

1 Safety Guidelines

Danger

:Suffocation from exhaust fume

￿Exhaust fume from the engine contains many elements harmful to human. Do not operate this equipment in poorly ventilated area, such as inside a room or in a tunnel

Danger

:Electrical Shock

￿Do not touch the output terminals during operation.

￿Be sure to place covers over the output terminals and fasten with fasteners.

￿Do not insert metal objects (such as pin or wire) into plug-in receptacles.

￿Do not touch wiring or any electronic parts inside equipment during operation.

￿Ground the every earth grounding terminal to the earth as set out in the manual.

￿If even one of all is unconnected by mistake or accident, it will be much more dangerous for human body than the NO RELAY case, because leaking current inevitably goes through the body.

￿Even though all the earth terminals of the loads have been grounded to the earth, the earth grounding terminal and the outer bonnet (canopy) grounding terminal should be grounded to the earth.

￿There is always a danger of being electrocuted by short-circuit. Be sure to test generator’s insulation resistance periodically.

￿Before connecting or disconnecting a load cable to/from output terminals, always turn a circuit breaker to OFF position, stop the engine, and remove the engine key. A person performing the maintenance should always keep the key.

￿Before performing any equipment check or maintenance, stop the engine, and remove the engine key. A person performing the maintenance should always keep the key.

Danger

:Injuries

￿Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.

Caution

:Suffocation from exhaust fume

￿Do not point the exhaust fume toward pedestrians or building.

-3 -

Image 3
Contents DG1000MI Introduction Injuries Safety GuidelinesSuffocation from exhaust fume Electrical ShockBurns Injuries to eyes and skinExplosion FireInjuries Location of Warning labels Specification Matrix SpecificationsUse Parts Ambient ConditionExternal view Control panel Monitor Display EquipmentEngine Oil Monitoring Lamp for oil pressure low Injuries Hour Meter built into the Tachometer Battery Charge Monitoring Lamp charge lampWater Temperature Gauge GaugesFrequency Meter Fuel GaugeGenerator Gauges Amp MeterSwitch Starter Switch Panel Light / Pilot LampEmergency Stop button Voltage Regulator and Throttle Lever Amp Meter Changeover SwitchThermal Relay Earth Leakage Relay UnitFuel Line Changeover Valve 3-way valve Using fuel from built-in fuel tank< > Transportation Transport and InstallationTransportation Lifting EquipmentInstallation ConnectionSelecting Cable Electrical damages Connecting Cable Load Connection Terminal Plate 3-Phase For 3-Phase LoadFor 1-Phase Load1 2 1-Phase Output Terminals & Receptacles For 1-Phase Load2Grounding Work Earth Leakage Relay and GroundingOperation Check Electrical Shock Fire Burns Initialization and pre-checkEarth leakage breaker relay has activated Electrical Shock InjuriesChecking Engine Oil Selecting proper engine oilEngine Oil Capacity Checking Coolant/water Checking Radiator / Adding waterChecking Coolant reservoir tank / Adding coolant Checking Fan Belt Coolant CapacityTension Condition Checking FuelChecking Fuel, Engine Oil, and Water leakage Checking BatteryReplacing the battery Initializing / preparation OperationFrequency Adjust Screw Damages to the property 200/400 Voltage Changeover Dual Voltage SystemDuring operation Refer to 7-2. Connecting cableProtection Features Feature ListStopping the Generator During Operation section Connecting to External Fuel TankMaintenance Generator side Engine SideReplace, refer to 8-1 Checking Engine Oil 10.1 Oil ChangeCleaning / Changing Air Filter Element Draining Water from Water Separator Cleaning / Changing Fuel FilterClean gauze filter in engine feed pump Clean gauze filter in water separatorIsuzu Part No 8970631550 Draining Water from Fuel Tank Long-term Storage Storage ProceduresStacking Troubleshooting Ask our distributor to repair Page Generator Wiring Diagram Engine Wiring Diagram

DG1000MI specifications

The Shindaiwa DG1000MI is a remarkable model in the world of portable generators, designed to deliver reliable power for both commercial and residential applications. Understanding its main features, technologies, and characteristics is vital for anyone considering a dependable power solution.

One of the most prominent features of the DG1000MI is its compact and lightweight design. Weighing in at approximately 66 pounds, it is easy to transport to various job sites, outdoor events, or even within your own backyard. Despite its size, the generator boasts a significant power output of up to 1000 watts, making it suitable for powering essential appliances, tools, and equipment.

This model is equipped with a powerful 4-stroke engine that ensures efficient fuel consumption while producing minimal emissions. This is particularly important for environmentally conscious users looking to reduce their carbon footprint. The DG1000MI operates quietly, which is beneficial in settings where noise regulations are in place.

An innovative feature of the DG1000MI is its advanced inverter technology. This ensures stable and clean power output, making it ideal for sensitive electronics such as laptops, smartphones, and other devices. The inverter technology regulates the voltage and frequency, providing a consistent power supply that reduces the risk of damage to valuable equipment.

The DG1000MI also offers extended run times, thanks to its efficient fuel management system. With a tank capacity of 1.6 gallons, users can expect 8 to 10 hours of operation on a single tank, depending on the load. This extended run time is a fantastic advantage for users who need consistent power over long durations without frequent refueling.

Maintenance is simplified with the DG1000MI, designed with user friendliness in mind. It features an easy-access oil fill, a large air filter, and a straightforward starting mechanism. This ensures that routine checks and servicing can be performed with minimal hassle.

Finally, Shindaiwa stands by the durability and reliability of the DG1000MI, which is built with robust materials to withstand the rigors of outdoor use. The generator is engineered to perform under various conditions, making it a trusted choice for those who require dependable power in any situation.

In conclusion, the Shindaiwa DG1000MI is an exceptional portable generator that combines efficiency, ease of use, and advanced technology. It is an ideal choice for anyone seeking a versatile and reliable power solution.