Shindaiwa DG1000MI manual Long-term Storage, Storage Procedures

Page 46

11 long-term Storage

Danger

:Electrical Shock ￿ Injuries

￿Before performing any equipment check or maintenance, stop the engine, and remove the engine key. A person performing the maintenance should always keep the key.

Caution

:Fire ￿ Burns

￿Temperature around muffler and exhaust can get extremely high. Keep any inflammable items (such as fuel, gas, paint, etc.) away from the equipment.

￿When checking engine, always stop the engine, and keep away from fire. Wait until the engine cools down, before performing any checks.

￿Always wipe any drip of Diesel fuel or oil. Do not use this equipment when a leak is found. Repair the equipment before use.

11.1Storage Procedures

If the generator will not be used for more than two months, perform the following maintenance and storage procedures.

Remove battery

Change engine oil

Drain fuel from fuel tank and fuel filter

Clean all parts, cover the generator, and keep it in the storage, away from dust and

<Caution>

￿ Recharge the removed battery once a month.

￿ Refer to the user’s manual for the care of the engine.

humidity.

- 46 -

Image 46
Contents DG1000MI Introduction Electrical Shock Safety GuidelinesSuffocation from exhaust fume InjuriesFire Injuries to eyes and skinExplosion BurnsInjuries Location of Warning labels Specifications Specification MatrixAmbient Condition Use PartsExternal view Control panel Equipment Monitor DisplayEngine Oil Monitoring Lamp for oil pressure low Injuries Gauges Battery Charge Monitoring Lamp charge lampWater Temperature Gauge Hour Meter built into the TachometerAmp Meter Fuel GaugeGenerator Gauges Frequency MeterPanel Light / Pilot Lamp Switch Starter SwitchEmergency Stop button Earth Leakage Relay Unit Amp Meter Changeover SwitchThermal Relay Voltage Regulator and Throttle LeverUsing fuel from built-in fuel tank Fuel Line Changeover Valve 3-way valve< > Lifting Equipment Transport and InstallationTransportation TransportationConnection InstallationSelecting Cable Electrical damages Load Connection Terminal Plate 3-Phase For 3-Phase Load Connecting CableFor 1-Phase Load1 For 1-Phase Load2 2 1-Phase Output Terminals & ReceptaclesEarth Leakage Relay and Grounding Grounding WorkOperation Check Electrical Shock Electrical Shock Injuries Initialization and pre-checkEarth leakage breaker relay has activated Fire BurnsSelecting proper engine oil Checking Engine OilEngine Oil Capacity Checking Radiator / Adding water Checking Coolant/waterChecking Coolant reservoir tank / Adding coolant Coolant Capacity Checking Fan BeltTension Checking Fuel ConditionChecking Battery Checking Fuel, Engine Oil, and Water leakageReplacing the battery Operation Initializing / preparationFrequency Adjust Screw 200/400 Voltage Changeover Dual Voltage System Damages to the propertyRefer to 7-2. Connecting cable During operationFeature List Protection FeaturesStopping the Generator Connecting to External Fuel Tank During Operation sectionMaintenance Engine Side Generator side10.1 Oil Change Replace, refer to 8-1 Checking Engine OilCleaning / Changing Air Filter Element Cleaning / Changing Fuel Filter Draining Water from Water SeparatorClean gauze filter in water separator Clean gauze filter in engine feed pumpIsuzu Part No 8970631550 Draining Water from Fuel Tank Storage Procedures Long-term StorageStacking Troubleshooting Ask our distributor to repair Page Generator Wiring Diagram Engine Wiring Diagram

DG1000MI specifications

The Shindaiwa DG1000MI is a remarkable model in the world of portable generators, designed to deliver reliable power for both commercial and residential applications. Understanding its main features, technologies, and characteristics is vital for anyone considering a dependable power solution.

One of the most prominent features of the DG1000MI is its compact and lightweight design. Weighing in at approximately 66 pounds, it is easy to transport to various job sites, outdoor events, or even within your own backyard. Despite its size, the generator boasts a significant power output of up to 1000 watts, making it suitable for powering essential appliances, tools, and equipment.

This model is equipped with a powerful 4-stroke engine that ensures efficient fuel consumption while producing minimal emissions. This is particularly important for environmentally conscious users looking to reduce their carbon footprint. The DG1000MI operates quietly, which is beneficial in settings where noise regulations are in place.

An innovative feature of the DG1000MI is its advanced inverter technology. This ensures stable and clean power output, making it ideal for sensitive electronics such as laptops, smartphones, and other devices. The inverter technology regulates the voltage and frequency, providing a consistent power supply that reduces the risk of damage to valuable equipment.

The DG1000MI also offers extended run times, thanks to its efficient fuel management system. With a tank capacity of 1.6 gallons, users can expect 8 to 10 hours of operation on a single tank, depending on the load. This extended run time is a fantastic advantage for users who need consistent power over long durations without frequent refueling.

Maintenance is simplified with the DG1000MI, designed with user friendliness in mind. It features an easy-access oil fill, a large air filter, and a straightforward starting mechanism. This ensures that routine checks and servicing can be performed with minimal hassle.

Finally, Shindaiwa stands by the durability and reliability of the DG1000MI, which is built with robust materials to withstand the rigors of outdoor use. The generator is engineered to perform under various conditions, making it a trusted choice for those who require dependable power in any situation.

In conclusion, the Shindaiwa DG1000MI is an exceptional portable generator that combines efficiency, ease of use, and advanced technology. It is an ideal choice for anyone seeking a versatile and reliable power solution.