Shindaiwa DG1000MI manual Operation, Initializing / preparation

Page 32

9 Operation

9.1 Initializing / preparation

:Suffocation from exhaust fume

￿Exhaust fume from the engine contains many elements harmful to human.

Do not operate this equipment in poorly ventilated area, such as inside a room or in a tunnel

Caution

:Suffocation from exhaust fume

 

￿Do not point the exhaust fume toward pedestrians or building.

Caution :Fire

￿Temperature around muffler and exhaust can get extremely high. Keep any inflammable items (such as fuel, gas, paint, etc.) away from the equipment.

￿Always operate this equipment on flat surface and, at least 1 meter away from any objects (wall, box, etc.).

Caution

:Injuries

￿Always place the equipment on a flat and stable surface, to keep the equipment from sliding.

￿When starting the engine, turn off the connected equipment and set the circuit breaker to OFF position.

Turn the circuit breaker for single-phase and 3-phase on the control panel to OFF position

Set the Throttle Lever to IDLING position.

Turn the starter switch to <START> position, and start the engine. In cold environment, turn

the starter switch to <Pre-heating> position, wait until the pre-heating status lamp comes on,

 

and start the engine

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREHEAT

 

 

 

 

 

 

 

 

 

 

 

REGULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXING SCREW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THROTTLE LEVER

 

 

 

 

 

 

 

 

 

 

FREQUENCY ADJUSTING SCREW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREAKER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THROTTLE LEVER

 

 

 

 

 

 

 

 

 

 

 

BREAKER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STARTER SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 32 -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 32
Contents DG1000MI Introduction Safety Guidelines Suffocation from exhaust fumeElectrical Shock InjuriesInjuries to eyes and skin ExplosionFire BurnsInjuries Location of Warning labels Specifications Specification MatrixExternal view Use PartsAmbient Condition Control panel Equipment Monitor DisplayEngine Oil Monitoring Lamp for oil pressure low Injuries Battery Charge Monitoring Lamp charge lamp Water Temperature GaugeGauges Hour Meter built into the TachometerFuel Gauge Generator GaugesAmp Meter Frequency MeterEmergency Stop button Switch Starter SwitchPanel Light / Pilot Lamp Amp Meter Changeover Switch Thermal RelayEarth Leakage Relay Unit Voltage Regulator and Throttle LeverUsing fuel from built-in fuel tank Fuel Line Changeover Valve 3-way valve< > Transport and Installation TransportationLifting Equipment TransportationSelecting Cable InstallationConnection Electrical damages For 1-Phase Load1 Connecting CableLoad Connection Terminal Plate 3-Phase For 3-Phase Load For 1-Phase Load2 2 1-Phase Output Terminals & ReceptaclesEarth Leakage Relay and Grounding Grounding WorkOperation Check Electrical Shock Initialization and pre-check Earth leakage breaker relay has activatedElectrical Shock Injuries Fire BurnsEngine Oil Capacity Checking Engine OilSelecting proper engine oil Checking Coolant reservoir tank / Adding coolant Checking Coolant/waterChecking Radiator / Adding water Tension Checking Fan BeltCoolant Capacity Checking Fuel ConditionChecking Battery Checking Fuel, Engine Oil, and Water leakageReplacing the battery Operation Initializing / preparationFrequency Adjust Screw 200/400 Voltage Changeover Dual Voltage System Damages to the propertyRefer to 7-2. Connecting cable During operationStopping the Generator Protection FeaturesFeature List Connecting to External Fuel Tank During Operation sectionMaintenance Engine Side Generator side10.1 Oil Change Replace, refer to 8-1 Checking Engine OilCleaning / Changing Air Filter Element Cleaning / Changing Fuel Filter Draining Water from Water SeparatorClean gauze filter in water separator Clean gauze filter in engine feed pumpIsuzu Part No 8970631550 Draining Water from Fuel Tank Storage Procedures Long-term StorageStacking Troubleshooting Ask our distributor to repair Page Generator Wiring Diagram Engine Wiring Diagram

DG1000MI specifications

The Shindaiwa DG1000MI is a remarkable model in the world of portable generators, designed to deliver reliable power for both commercial and residential applications. Understanding its main features, technologies, and characteristics is vital for anyone considering a dependable power solution.

One of the most prominent features of the DG1000MI is its compact and lightweight design. Weighing in at approximately 66 pounds, it is easy to transport to various job sites, outdoor events, or even within your own backyard. Despite its size, the generator boasts a significant power output of up to 1000 watts, making it suitable for powering essential appliances, tools, and equipment.

This model is equipped with a powerful 4-stroke engine that ensures efficient fuel consumption while producing minimal emissions. This is particularly important for environmentally conscious users looking to reduce their carbon footprint. The DG1000MI operates quietly, which is beneficial in settings where noise regulations are in place.

An innovative feature of the DG1000MI is its advanced inverter technology. This ensures stable and clean power output, making it ideal for sensitive electronics such as laptops, smartphones, and other devices. The inverter technology regulates the voltage and frequency, providing a consistent power supply that reduces the risk of damage to valuable equipment.

The DG1000MI also offers extended run times, thanks to its efficient fuel management system. With a tank capacity of 1.6 gallons, users can expect 8 to 10 hours of operation on a single tank, depending on the load. This extended run time is a fantastic advantage for users who need consistent power over long durations without frequent refueling.

Maintenance is simplified with the DG1000MI, designed with user friendliness in mind. It features an easy-access oil fill, a large air filter, and a straightforward starting mechanism. This ensures that routine checks and servicing can be performed with minimal hassle.

Finally, Shindaiwa stands by the durability and reliability of the DG1000MI, which is built with robust materials to withstand the rigors of outdoor use. The generator is engineered to perform under various conditions, making it a trusted choice for those who require dependable power in any situation.

In conclusion, the Shindaiwa DG1000MI is an exceptional portable generator that combines efficiency, ease of use, and advanced technology. It is an ideal choice for anyone seeking a versatile and reliable power solution.