Multiquip DCA180SSK manual DCA-180SSK Installation, Outdoor Installation

Page 40

Outdoor Installation

Install the generator in a location where it will not be exposed to rain or sunshine. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to the engine parts and the alternator.

CAUTION :

Pay close attention to ventilation when operating the generator inside tunnels and caves. The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.

Indoor Installation

Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside.The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

DCA-180SSK — INSTALLATION

CAUTION :

An electric shock may happen when vibrators are used. Pay close attention to handling when operating vibrators and always use rubber boots and gloves to insulate the body from electrical shock.

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generator to earth ground.

a.Copper - 10 AWG (5.3 mm2) or larger.

b.Aluminum - 8 AWG (8.4 mm2) or larger.

2.When grounding the generator (Figure 27) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried a minimum of 8 ft. into the ground.

NOTE

When connecting the generator to any buildings electrical system ALWAYS consult with a licensed electrician.

PAGE 40 — DCA-180SSK — PARTS AND OPERATION MANUAL — REV. #3 (06/11/09)

Image 40
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Parts Ordering Procedures Ordering parts has never been easierGeneral Safety Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneTransporting Maintenance SafetyEmergencies Towing Safety Precautions DCA-180SSK TowingDCA-180SSK TRAILER-SAFETY Guidelines Explanation of ChartDCA-180SSK -TRAILER-SPECIFICATIONS SystemDCA-180SSK -TRAILER-SPECIFICATIONS AxleDCA-180SSK -TRAILER Safety Guidelines Electric Brake AdjustmentBrakes Electric BrakesDCA-180SSK -TRAILER Safety Guidelines Hydraulic/Air/Surge BrakesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Torque Ft.-Lbs DCA-180SSK -TRAILER Safety GuidelinesLug Nut Torque Requirements DCA-180SSK -TRAILER-WIRING Diagram DCA-180SSK -TRAILER-BRAKETROUBLESHOOTING Electric Brake TroubleshootingDCA-180SSK -TRAILER-BRAKETROUBLESHOOTING Hydraulic Brake TroubleshootingDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Specifications Generator SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options DCA-180SSK Major Components Major ComponentsDCA-180SSK Dimensions TOP, SIDE, and Rear DimensionsDCA-180SSK Control Panel Control PanelDCA-180SSK Control Panel Mpec ModuleDCA-180SSK Engine Operating Panel Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Over Current Relay Output Terminal Panel Available VoltagesMaximum Amps How to read the output terminal gauges DCA-180SSK Outputterminal Panel OverviewSingle Phase, 240 Volt Phase, 240 VoltSingle Phase, 139 Volt Voltage Change-over BoardPhase, 480Volt Single Phase, 480 VoltSingle Phase, 277 Volt DCA-180SSK Installation Outdoor InstallationDCA-180SSK Installation Typical Generator Grounding ApplicationDCA-180SSK PRE-SETUP General Inspection Prior to OperationTemperature Range Type Oil Lubrication OilCleaning the Radiator Air CleanerOperation in Freezing Weather Fan Belt TensionWiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadDCA-180SSK Load Application Before Starting Engine Before Starting Generator and Control PanelDCA-180SSK Generator START-UP Procedure VAC Accessory Receptacle/CableSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Engine Shutdown Emergency StopDCA-180SSK Maintenance DCA-180SSK Maintenance Check Electric Heater If equippedChanging Oil Replacing fuel filterGreasing Cleaning breather elementGenerator Storage Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram DCA-180SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-180SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINE Diagnosed based on the Generator Troubleshooting TableDCA-180SSK -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnDCA-180SSK Suggested Spare Parts Qty DescriptionDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.