Multiquip DCA180SSK manual Part Name QTY

Page 95

DCA-180SSK — NAME PLATE AND DECALS

NAME PLATE AND DECALS

NO

PART NO

PART NAME

QTY.

REMARKS

 

 

OUTPUT TERMINAL GROUP

 

 

5-1

0840614104

DECAL; GROUND

1

S-2635

5-2

0840619904

DECAL; DANGER HIGH VOLTAGE

1

S-2731

5-3

9039209064

DECAL; START CONTACT

1

S-4468

5-4

B9511100304

DECAL; WARNING

1

B91110030

5-5

B9511100404

DECAL; WARNING ELECTRIC SHOCK

 

 

 

 

HAZARD

1

B91110040

5-6

B9531100504

DECAL; WARNING ELECTRIC SHOCK

1

B93110050

 

 

HAZARD

 

 

5-7

C0551000404

DECAL; 3-PHASE OUTPUT TERMINAL

1

C05100040

5-8

C0551001503

DECAL; RECEPTACLE & CIRCUIT

 

 

 

 

BREAKER

1

C05100150

5-9

C1552000204

DECAL; WATER HEATER

1

C15200020

5-10

C1552000304

DECAL; BATTERY CHARGER

1

C15200030

 

 

BATTERY GROUP

 

 

6-1

0800689404

DECAL; +

1

S-2090

6-2

0800689504

DECAL; -

1

S-2091

6-3

C9505300004

DECAL; CAUTION

1

C90530000

 

 

MUFFLER GROUP

 

 

7-1

B9504200004

DECAL; WARNING ENGINE EXHAUST

1

B90420000

 

 

FUEL PIPING GROUP

 

 

8-1

0800688404

DECAL; FUEL INLET

1

S-1344

8-2

0800688504

DECAL; FUEL OUTLET

1

S-1345

8-3

1320620904

DECAL; DIESEL FUEL

1

S-1756

8-4

B9504500004

DECAL; WARNING DIESEL FUEL

1

B90450000

 

 

ENCLOSURE GROUP

 

 

9-1

1320621504

DECAL; SUPPORT HOOK

2

S-2257

9-2

0600500090

EMBLEM

2

 

 

0021106016

MACHINE SCREW

4

 

DCA-180SSK — PARTS AND OPERATION MANUAL— REV. #3 (06/11/09) — PAGE 95

Image 95
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Ordering parts has never been easier Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryEmergencies Maintenance SafetyTransporting DCA-180SSK Towing Towing Safety PrecautionsExplanation of Chart DCA-180SSK TRAILER-SAFETY GuidelinesSystem DCA-180SSK -TRAILER-SPECIFICATIONSAxle DCA-180SSK -TRAILER-SPECIFICATIONSElectric Brakes DCA-180SSK -TRAILER Safety GuidelinesElectric Brake Adjustment BrakesHydraulic/Air/Surge Brakes DCA-180SSK -TRAILER Safety GuidelinesSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements DCA-180SSK -TRAILER Safety GuidelinesTorque Ft.-Lbs DCA-180SSK -TRAILER-WIRING Diagram Electric Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGHydraulic Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals Generator Specifications DCA-180SSK SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options Major Components DCA-180SSK Major ComponentsDimensions DCA-180SSK Dimensions TOP, SIDE, and RearControl Panel DCA-180SSK Control PanelMpec Module DCA-180SSK Control PanelEngine Operating Panel DCA-180SSK Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Maximum Amps Output Terminal Panel Available VoltagesOver Current Relay DCA-180SSK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltSingle Phase, 277 Volt Single Phase, 480 VoltPhase, 480Volt Outdoor Installation DCA-180SSK InstallationTypical Generator Grounding Application DCA-180SSK InstallationGeneral Inspection Prior to Operation DCA-180SSK PRE-SETUPLubrication Oil Temperature Range Type OilFan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherPiping and Hose Connection Battery Cable InstallationWiring DCA-180SSK Load Application Single Phase LoadThree Phase Load Before Starting Generator and Control Panel Before Starting EngineVAC Accessory Receptacle/Cable DCA-180SSK Generator START-UP ProcedureSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Emergency Stop Engine ShutdownDCA-180SSK Maintenance Replacing fuel filter DCA-180SSK MaintenanceCheck Electric Heater If equipped Changing OilGenerator Storage Cleaning breather elementGreasing Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram Engine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineEngine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineDiagnosed based on the Generator Troubleshooting Table DCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-180SSK -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-180SSK Suggested Spare PartsDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.