Multiquip DCA180SSK manual Part Name QTY Remarks

Page 67

DCA-180SSK — GENERATOR ASSY.

GENERATOR ASSY.

 

 

 

NO

PART NO

PART NAME

QTY.

REMARKS

1

C0110100102

ROTOR ASSEMBLY

1

INCLUDE ITEMS W/*

2*

0071906314

BEARING

1

6314 DDU C3

3*

C1112500004

BEARING FLANGE

1

 

4*

0601823282

RECTIFIER

1

RM50TC-24

5*

0018205020

HEX. CAP SCREW

2

 

6*

0040005000

LOCK WASHER

2

 

7*

0041205000

PLAIN WASHER

2

 

8*

0601000209

BALANCING WEIGHT KIT

1

 

9*

0601842334

RESISTOR

1

SMRK 80W 100kS

10*

0042616000

LOCK WASHER

8

 

11*

8171070002

FAN

1

 

12*

8171611003

COUPLING DISK

9

 

13*

C1164200004

WASHER, COUPLING HUB

1

 

14*

81710-15003

BALANCING PLATE

1

 

15

0012116045

HEX. HEAD BOLT

8

 

16

06050-00012

RUBBER SUSPENSION

2

 

17*

0012112040

HEX. HEAD BOLT

8

 

18

8301614003

COUPLING RING

1

 

19

0012112035

HEX. HEAD BOLT

8

 

20

C1154400004

COVER, BEARING

1

 

21

0010106060

HEX. HEAD BOLT

4

 

22

0040006000

LOCK WASHER

4

 

23

0041206000

PLAIN WASHER

5

 

24

C1154300004

GASKET, BEARING

1

 

25

0017106016

HEX. HEAD BOLT

8

 

26

C1154400103

SUCTION COVER

1

 

27

0017112045

HEX. HEAD BOLT

6

 

28

C1154000002

END BRACKET

1

 

29

0012110065

HEX. HEAD BOLT

4

 

30

0042610000

LOCK WASHER

4

 

31

0041210000

PLAIN WASHER

4

 

32

C1138000003

FIELD ASS’Y EXCITER

1

 

33

C0130100003

STATOR ASSEMBLY

1

INCLUDE ITEMS W/#

34#

0845041804

GROMMET

2

 

35#

0601850144

GROMMET

1

 

36#

0012112035

HEX. HEAD BOLT

12

 

37

0042512000

LOCK WASHER

27

 

38

C0132300003

COVER, FAN

1

 

39

0010106030

HEX. HEAD BOLT

1

 

40

0040020000

LOCK WASHER

4

 

41

0030020000

HEX. NUT

4

 

42*

0042512000

LOCK WASHER

1

 

DCA-180SSK — PARTS AND OPERATION MANUAL— REV. #3 (06/11/09) — PAGE 67

Image 67
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Ordering parts has never been easier Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryTransporting Maintenance SafetyEmergencies DCA-180SSK Towing Towing Safety PrecautionsExplanation of Chart DCA-180SSK TRAILER-SAFETY GuidelinesSystem DCA-180SSK -TRAILER-SPECIFICATIONSAxle DCA-180SSK -TRAILER-SPECIFICATIONSElectric Brakes DCA-180SSK -TRAILER Safety GuidelinesElectric Brake Adjustment BrakesHydraulic/Air/Surge Brakes DCA-180SSK -TRAILER Safety GuidelinesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Torque Ft.-Lbs DCA-180SSK -TRAILER Safety GuidelinesLug Nut Torque Requirements DCA-180SSK -TRAILER-WIRING Diagram Electric Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGHydraulic Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals Generator Specifications DCA-180SSK SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options Major Components DCA-180SSK Major ComponentsDimensions DCA-180SSK Dimensions TOP, SIDE, and RearControl Panel DCA-180SSK Control PanelMpec Module DCA-180SSK Control PanelEngine Operating Panel DCA-180SSK Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Over Current Relay Output Terminal Panel Available VoltagesMaximum Amps DCA-180SSK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltPhase, 480Volt Single Phase, 480 VoltSingle Phase, 277 Volt Outdoor Installation DCA-180SSK InstallationTypical Generator Grounding Application DCA-180SSK InstallationGeneral Inspection Prior to Operation DCA-180SSK PRE-SETUPLubrication Oil Temperature Range Type OilFan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherWiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadDCA-180SSK Load Application Before Starting Generator and Control Panel Before Starting EngineVAC Accessory Receptacle/Cable DCA-180SSK Generator START-UP ProcedureSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Emergency Stop Engine ShutdownDCA-180SSK Maintenance Replacing fuel filter DCA-180SSK MaintenanceCheck Electric Heater If equipped Changing OilGreasing Cleaning breather elementGenerator Storage Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram Engine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineEngine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineDiagnosed based on the Generator Troubleshooting Table DCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-180SSK -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-180SSK Suggested Spare PartsDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.