Multiquip DCA180SSK manual DCA-180SSK Maintenance

Page 54

DCA-180SSK — MAINTENANCE

General Inspection

Prior to each use, the generating set should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel or oil leaks.

Air Cleaner

Every 50 hours: If dust indicator is red, clean the air cleaner element.

Outer Element:

1.Loosen wing bolt, remove dust cup, then remove wing nut and take out element.

2.Clean the inside of the body and cover using a damp cloth.

3.Blow dry with compressed air (0.69Mpa {7kgf.cm2, 99.4 PSI} maximum against the side of the element along the pleats. Then blow dry against outside along the pleats, then against inside again.

4.Remove one seal each time the element is cleaned.

5.Replace the outer element after cleaning it 6 times or after one year. Replace the outer element if indicator is red even after cleaning it.

6.Check the inner cylinder element clamping nut for looseness, and retighten if necessary.

7.If seal washer is damaged or the threads of wing nut are damaged, replace.

8.Remove evacuator valve and clean it with compressed air. Reinstall.

Inner element (if equipped)

1.Remove the cover and outer element, then remove the inner element.

2.Cover the air connector opening (outer side) with clean cloth or cloth tape.

3.Clean the inside of the body. Remove air connector opening protection.

4.Install a new inner cylinder element to the cylinder and tighten the nut.

5.Install element.

6.After replacing the element, press the button of the dust indicator to return the red piston to its original position.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations). Always pour through the mesh filter.

Removing Water from the Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally remove the drain cock and drain the contents. During cold weather, the greater the empty volume inside the tank, the easier it is for water to condense. This can be reduced by always keeping the tank as full as possible.

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure.

To restart after running out of fuel, turn the key switch to the “START” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Service Daily

If engine is operating in very dusty and dry grass conditions, a clogged air cleaner will result in high fuel consumption, loss of power and excessive carbon buildup in the combustion chamber.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in diesel. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 28, page 43.

Flushing Out Radiator and Changing Coolant

1.Stop the engine and allow to cool. Tighten valve of the corrosion resistor (if equipped).

2.Turn water filer cap slowly and remove it.

3.Prepare a container to catch the coolant, then open drain plug of the radiator or heat exchanger and drain plug of the engine, and drain the coolant.

4.After draining the coolant, close drain plugs and fill with tap water.

PAGE 54 — DCA-180SSK — PARTS AND OPERATION MANUAL — REV. #3 (06/11/09)

Image 54
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Parts Ordering Procedures Ordering parts has never been easierGeneral Safety Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneMaintenance Safety TransportingEmergencies Towing Safety Precautions DCA-180SSK TowingDCA-180SSK TRAILER-SAFETY Guidelines Explanation of ChartDCA-180SSK -TRAILER-SPECIFICATIONS SystemDCA-180SSK -TRAILER-SPECIFICATIONS AxleBrakes DCA-180SSK -TRAILER Safety GuidelinesElectric Brake Adjustment Electric BrakesDCA-180SSK -TRAILER Safety Guidelines Hydraulic/Air/Surge BrakesTires/Wheels/Lug Nuts Tire Wear/InflationSuspension DCA-180SSK -TRAILER Safety Guidelines Torque Ft.-LbsLug Nut Torque Requirements DCA-180SSK -TRAILER-WIRING Diagram DCA-180SSK -TRAILER-BRAKETROUBLESHOOTING Electric Brake TroubleshootingDCA-180SSK -TRAILER-BRAKETROUBLESHOOTING Hydraulic Brake TroubleshootingDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Specifications Generator SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options DCA-180SSK Major Components Major ComponentsDCA-180SSK Dimensions TOP, SIDE, and Rear DimensionsDCA-180SSK Control Panel Control PanelDCA-180SSK Control Panel Mpec ModuleDCA-180SSK Engine Operating Panel Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Output Terminal Panel Available Voltages Over Current RelayMaximum Amps How to read the output terminal gauges DCA-180SSK Outputterminal Panel OverviewSingle Phase, 139 Volt Single Phase, 240 VoltPhase, 240 Volt Voltage Change-over BoardSingle Phase, 480 Volt Phase, 480VoltSingle Phase, 277 Volt DCA-180SSK Installation Outdoor InstallationDCA-180SSK Installation Typical Generator Grounding ApplicationDCA-180SSK PRE-SETUP General Inspection Prior to OperationTemperature Range Type Oil Lubrication OilOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt TensionBattery Cable Installation WiringPiping and Hose Connection Single Phase Load Three Phase LoadDCA-180SSK Load Application Before Starting Engine Before Starting Generator and Control PanelDCA-180SSK Generator START-UP Procedure VAC Accessory Receptacle/CableSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Engine Shutdown Emergency StopDCA-180SSK Maintenance Changing Oil DCA-180SSK MaintenanceCheck Electric Heater If equipped Replacing fuel filterCleaning breather element GreasingGenerator Storage Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram DCA-180SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-180SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINE Diagnosed based on the Generator Troubleshooting TableDCA-180SSK -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnDCA-180SSK Suggested Spare Parts Qty DescriptionDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.