DCA-180SSK —TROUBLESHOOTING (MPEC)

TABLE 18. MPEC TROUBLESHOOTING

Sympton

Possible Cause

Solution

 

 

 

 

Low oil level?

Fill oil level.

 

 

 

Low oil pressure

Oil pressure sending unit failure?

Replace oil pressure sending unit.

 

 

light is on.

Time delay malfuntion in MPEC?

Refer to dealer.

 

 

 

 

 

Wire shorted?

Inspect/repair wire.

 

 

 

 

Low coolant level?

Fill coolant level.

Low coolant level

 

 

Sending unit failure?

Replace sending unit.

light is on.

 

 

 

Low battery voltage?

Replace/charge battery.

 

 

 

 

Fan belt tension incorrect?

Tighten/replace fan belt.

 

 

 

 

Air flow is not circulation through

Clean/repair radiator grill.

 

radiator?

 

 

 

 

 

 

Doors open?

Close doors.

High coolant

 

 

Exhaust leaking?

Replace/repair gaskets or faulty part.

temperture light is

 

 

on.

Generator being overloaded?

Check/reduce load.

 

 

 

 

 

Thermostat failure?

Replace thermostat.

 

 

 

 

Air intake blocked?

Clear all air intakes.

 

 

 

 

Temperature switch failure?

Replace temperature switch.

 

 

 

Overcrank light is

No or low Fuel?

Fill fuel level.

 

 

on.

MPEC needs to be calibrated?

Refer to dealer.

 

 

 

 

 

RPM engine speed too high?

Adjust RPM.

 

 

 

Overspeed light is

Governor actuator needs to be adjusted?

Adjust governor actuator.

 

 

Governor controller needs to be

 

on.

Adjust governor controller.

 

adjusted?

 

 

 

 

 

 

MPEC needs to be calibrated?

Refer to dealer.

 

 

 

Loss of MPU

Magnetic pick up out of adjustment?

Adjust magnetic pick up.

 

 

light(s) or on.

Magnetic pick up dirty?

Clean magnetic pick up.

 

 

 

 

DCA-180SSK — PARTS AND OPERATION MANUAL— REV. #3 (06/11/09) — PAGE 63

Image 63
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Ordering parts has never been easier Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryMaintenance Safety TransportingEmergencies DCA-180SSK Towing Towing Safety PrecautionsExplanation of Chart DCA-180SSK TRAILER-SAFETY GuidelinesSystem DCA-180SSK -TRAILER-SPECIFICATIONSAxle DCA-180SSK -TRAILER-SPECIFICATIONSElectric Brakes DCA-180SSK -TRAILER Safety GuidelinesElectric Brake Adjustment BrakesHydraulic/Air/Surge Brakes DCA-180SSK -TRAILER Safety GuidelinesTires/Wheels/Lug Nuts Tire Wear/InflationSuspension DCA-180SSK -TRAILER Safety Guidelines Torque Ft.-LbsLug Nut Torque Requirements DCA-180SSK -TRAILER-WIRING Diagram Electric Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGHydraulic Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals Generator Specifications DCA-180SSK SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options Major Components DCA-180SSK Major ComponentsDimensions DCA-180SSK Dimensions TOP, SIDE, and RearControl Panel DCA-180SSK Control PanelMpec Module DCA-180SSK Control PanelEngine Operating Panel DCA-180SSK Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Output Terminal Panel Available Voltages Over Current RelayMaximum Amps DCA-180SSK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltSingle Phase, 480 Volt Phase, 480VoltSingle Phase, 277 Volt Outdoor Installation DCA-180SSK InstallationTypical Generator Grounding Application DCA-180SSK InstallationGeneral Inspection Prior to Operation DCA-180SSK PRE-SETUPLubrication Oil Temperature Range Type OilFan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherBattery Cable Installation WiringPiping and Hose Connection Single Phase Load Three Phase LoadDCA-180SSK Load Application Before Starting Generator and Control Panel Before Starting EngineVAC Accessory Receptacle/Cable DCA-180SSK Generator START-UP ProcedureSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Emergency Stop Engine ShutdownDCA-180SSK Maintenance Replacing fuel filter DCA-180SSK MaintenanceCheck Electric Heater If equipped Changing OilCleaning breather element GreasingGenerator Storage Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram Engine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineEngine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineDiagnosed based on the Generator Troubleshooting Table DCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-180SSK -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-180SSK Suggested Spare PartsDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.