Multiquip DCA180SSK manual DCA-180SSK Maintenance, Check Electric Heater If equipped, Changing Oil

Page 55

DCA-180SSK — MAINTENANCE

5.When the water level is near the mouth of the water filler, open drain plugs and start the engine, and run at low idling. Keep the engine running at low idling and flush the radiator for about 10 minutes.

6.Adjust the flow of the water flowing in and draining out to ensure that the radiator is always full during the flushing operation, While flushing water through the system, watch carefully the water inlet hose does not come out of the radiator filler port.

7.After flushing, stop the engine, open drain plug and drain the water, then close drain plugs.

8.After draining the water, flush the system with a flushing agent. See instructions on flushing agent label.

9.After flushing, open drain plugs and drain out all the water, then close drain plugs and add tap water so the water level is near the mouth of the water filler.

10.When the water level is near the mouth of the water filler, open drain plugs and start the engine, run at low idling and continue to flush the system until clean water comes out. Adjust the flow of the water flowing in and draining out to ensure the radiator is always full during the flushing operation.

11.When clean water comes out, stop the engine, drain all the water, then close drain plugs.

12.Remove the corrosion resistor (if equipped) and open valve.

13.Supply water until it flows over the water filler.

14.Drain the water inside reserve tank, clean the inside of the reserve tank, then fill with coolant/water mixture to between the full and low lines.

15.Stop the engine, wait for 3 minutes, add tap water until the water level reaches near the water filer port, then tighten the radiator cap.

Check Electric Heater (If equipped)

Before starting in cold weather (once a year), please contact your Komatsu distributor for inspection. Remove electric heater from the engine intake manifold and check for disconnections or dirt. When checking or installing the electric heater, replace the gasket with a new part.

Changing Oil

1.Make sure the oil is cool before changing.

2.Set a container directly under the drain plug of the oil pan. Loosen the drain plug slowly.

3.Check the drained oil for excessive metal particles or foreign material. Contact the distributor if there is metal particles or foreign material.

4.Using a filter wrench, turn filter cartridge to the left to remove it. If the filter cartridge is filled with a large amount of oil, wait 10 minutes or so before removing. Make sure there is no old gasket stuck on the filter holder.

5.Tighten drain plug. Clean the filter holder, fill the new filter cartridge with clean engine oil, coat the packing and thread of the new filter cartridge with engine oil, then install it to the filter holder. Tighten until the gasket surface contacts the seal surface of the filter holder, then tighten it a further 3/4 to 1 turn.

6.Add engine oil through oil filler until the oil level is between the H and L marks on the dipstick.

7.Run the engine at idling for a short time, then stop the engine. Recheck the oil level and fill as necessary.

Replacing fuel filter

1.Set the container under the filter cartridge to catch fuel.

2.Using a filter wrench, turn the filter cartridge to the left to remove it.

3.Clean the filter holder, fill the new filter cartridge with fuel, coat the packing surface of the filter cartridge with engine oil, then install the cartridge to the filter holder.

4.When installing, tighten until the packing surface contacts the seal surface of the filter holder then tighten a further 2/3 of a turn. If the filter cartridge is tighten too much, the packing will be damaged and will cause fuel leakage. Fuel leakage will occur if the filter cartridge is not tightened enough. Always tighten to the correct angle.

5.After replacing filter cartridge, loosen air bleed plug.

6.Loosen the knob of feed pump, and pump it up and down until no bubbles come our with the fuel from air bleed plug.

DCA-180SSK — PARTS AND OPERATION MANUAL— REV. #3 (06/11/09) — PAGE 55

Image 55
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Ordering parts has never been easier Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryTransporting Maintenance SafetyEmergencies DCA-180SSK Towing Towing Safety PrecautionsExplanation of Chart DCA-180SSK TRAILER-SAFETY GuidelinesSystem DCA-180SSK -TRAILER-SPECIFICATIONSAxle DCA-180SSK -TRAILER-SPECIFICATIONSElectric Brakes DCA-180SSK -TRAILER Safety GuidelinesElectric Brake Adjustment BrakesHydraulic/Air/Surge Brakes DCA-180SSK -TRAILER Safety GuidelinesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Torque Ft.-Lbs DCA-180SSK -TRAILER Safety GuidelinesLug Nut Torque Requirements DCA-180SSK -TRAILER-WIRING Diagram Electric Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGHydraulic Brake Troubleshooting DCA-180SSK -TRAILER-BRAKETROUBLESHOOTINGDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals Generator Specifications DCA-180SSK SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options Major Components DCA-180SSK Major ComponentsDimensions DCA-180SSK Dimensions TOP, SIDE, and RearControl Panel DCA-180SSK Control PanelMpec Module DCA-180SSK Control PanelEngine Operating Panel DCA-180SSK Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Over Current Relay Output Terminal Panel Available VoltagesMaximum Amps DCA-180SSK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltPhase, 480Volt Single Phase, 480 VoltSingle Phase, 277 Volt Outdoor Installation DCA-180SSK InstallationTypical Generator Grounding Application DCA-180SSK InstallationGeneral Inspection Prior to Operation DCA-180SSK PRE-SETUPLubrication Oil Temperature Range Type OilFan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherWiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadDCA-180SSK Load Application Before Starting Generator and Control Panel Before Starting EngineVAC Accessory Receptacle/Cable DCA-180SSK Generator START-UP ProcedureSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Emergency Stop Engine ShutdownDCA-180SSK Maintenance Replacing fuel filter DCA-180SSK MaintenanceCheck Electric Heater If equipped Changing OilGreasing Cleaning breather elementGenerator Storage Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram Engine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineEngine Troubleshooting DCA-180SSK -TROUBLESHOOTING EngineDiagnosed based on the Generator Troubleshooting Table DCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-180SSK -TROUBLESHOOTING MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-180SSK Suggested Spare PartsDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.