Multiquip DCA180SSK manual DCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINE

Page 62

DCA-180SSK —TROUBLESHOOTING (GENERATOR/ENGINE)

Practically all generator breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the

diagnosed based on the Generator Troubleshooting (Table

17)and the MPEC troubleshooting (Table 18) information shown . If the problem cannot be remedied, consult our company's business office or service plant.

TABLE 17. ENGINE & GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Dead battery?

Replace battery.

Engine fails to start and

 

 

Defective starter switch?

Replace switch.

starter does not rotated.

 

 

 

Fuse F5 burned out?

Replace fuse.

 

 

 

 

Broken pre-heat circuit?

Check pre-heat circuit.

Engine fails to start and

 

 

No fuel?

Add fuel.

starter rotates.

 

 

 

Defective wiring?

Check wiring.

 

 

 

 

Clogged fuel strainer?

Clean or replace.

Engine starts and remains at

 

 

Clogged air cleaner?

Clean or replace.

low speed.

 

 

 

Disconnected wiring?

Check and repair wiring.

 

 

 

 

No voltage present in AC

Replace rectifier (RE1).

 

power source?

 

 

 

 

 

Engine speed rises and no

Defective rotor?

Replace rotor.

 

 

Defective voltmeter?

Replace voltmeter.

voltage is present in AC

power source.

 

 

Disconnected wiring?

Check and repair wiring.

 

 

 

 

 

Layer short-circuit in armature

Replace armature.

 

winding?

 

 

 

 

 

Engine speed rises and AC

Defective circuit breaker

Replace circuit breaker (protector).

(protector)?

 

power voltage is too low or

 

 

Layer short-circuit, broken

 

cannot be used.

Repair or replace armature.

 

wires in armature winding?

 

 

 

 

 

Engine speed rises and

Defective engine regulator?

Replace regulator.

 

 

battery discharges too soon.

Defective wiring?

Repair or replace wiring.

 

 

 

Engine speed rises and

Defective alternator?

Repair or replace alternator.

 

 

engine seems overloaded.

Damaged alternator bearing?

Replace alternator bearings.

 

 

 

 

PAGE 62 — DCA-180SSK — PARTS AND OPERATION MANUAL — REV. #3 (06/11/09)

Image 62
Contents Whisperwatt Series Proposition 65 Warning Page Table of Contents Parts Ordering Procedures Ordering parts has never been easierGeneral Safety Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneEmergencies Maintenance SafetyTransporting Towing Safety Precautions DCA-180SSK TowingDCA-180SSK TRAILER-SAFETY Guidelines Explanation of ChartDCA-180SSK -TRAILER-SPECIFICATIONS SystemDCA-180SSK -TRAILER-SPECIFICATIONS AxleBrakes DCA-180SSK -TRAILER Safety GuidelinesElectric Brake Adjustment Electric BrakesDCA-180SSK -TRAILER Safety Guidelines Hydraulic/Air/Surge BrakesSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements DCA-180SSK -TRAILER Safety GuidelinesTorque Ft.-Lbs DCA-180SSK -TRAILER-WIRING Diagram DCA-180SSK -TRAILER-BRAKETROUBLESHOOTING Electric Brake TroubleshootingDCA-180SSK -TRAILER-BRAKETROUBLESHOOTING Hydraulic Brake TroubleshootingDCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Operation and Safety Decals DCA-180SSK Specifications Generator SpecificationsDCA-180SSK General Information DCA-180SSK General Information Options DCA-180SSK Major Components Major ComponentsDCA-180SSK Dimensions TOP, SIDE, and Rear DimensionsDCA-180SSK Control Panel Control PanelDCA-180SSK Control Panel Mpec ModuleDCA-180SSK Engine Operating Panel Engine Operating PanelDCA-180SSK Engine Operating Panel DCA-180SSK Outputterminal Panel Overview DCA-180SSK Outputterminal Panel Overview Maximum Amps Output Terminal Panel Available VoltagesOver Current Relay How to read the output terminal gauges DCA-180SSK Outputterminal Panel OverviewSingle Phase, 139 Volt Single Phase, 240 VoltPhase, 240 Volt Voltage Change-over BoardSingle Phase, 277 Volt Single Phase, 480 VoltPhase, 480Volt DCA-180SSK Installation Outdoor InstallationDCA-180SSK Installation Typical Generator Grounding ApplicationDCA-180SSK PRE-SETUP General Inspection Prior to OperationTemperature Range Type Oil Lubrication OilOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt TensionPiping and Hose Connection Battery Cable InstallationWiring DCA-180SSK Load Application Single Phase LoadThree Phase Load Before Starting Engine Before Starting Generator and Control PanelDCA-180SSK Generator START-UP Procedure VAC Accessory Receptacle/CableSet the battery switch to on Figure Frequency Meter Hz Engine Tachometer DCA-180SSK Generator START-UP Procedure Auto Engine Shutdown Emergency StopDCA-180SSK Maintenance Changing Oil DCA-180SSK MaintenanceCheck Electric Heater If equipped Replacing fuel filterGenerator Storage Cleaning breather elementGreasing Inspection / Maintenance DCA-180SSK Generatorwiring Diagram DCA-180SSK Engine Wiring Diagram DCA-180SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-180SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-180SSK -TROUBLESHOOTING GENERATOR/ENGINE Diagnosed based on the Generator Troubleshooting TableDCA-180SSK -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnDCA-180SSK Suggested Spare Parts Qty DescriptionDCA-180SSK Generator Assy Part Name QTY Remarks DCA-180SSK Control Panel Assy Part Name QTY. Remarks DCA-180SSK Control BOX Assy Control BOX DCA-180SSK Engine Radiator Assy Dust Sensor DCA-180SSK Engine Operating Panel Assy Operating Panel DCA-180SSK Outputterminal Assy SET BOARD, Output Terminal DCA-180SSK Battery Assy Aisp DCA-180SSK Muffler Assy Sheet DCA-180SSK Fueltank Assy Part Name DCA-180SSK Enclosure Assy Side Door DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Assy DCA-180SSK Enclosure Lining Assy C0494404104 DCA-180SSK Enclosure ASSY. Rubber Seals Part Name QTY DCA-180SSK Name Plate and Decals Control BOX Group DCA-180SSK Name Plate and Decals Part Name QTY Effective July 1 Page HERE’S HOW to GET Help

DCA180SSK specifications

The Multiquip DCA180SSK is a powerful and versatile generator specifically designed for construction sites, events, and other demanding applications. This model boasts an impressive power output of 180 kVA, making it suitable for a wide range of electrical needs. Its reliable performance combined with advanced features makes it a preferred choice for professionals in various industries.

One of the standout characteristics of the DCA180SSK is its robust, diesel-powered engine. This generator is equipped with a reliable Yanmar diesel engine, known for its durability and efficiency. The engine not only ensures consistent power delivery but also meets stringent emission regulations, making it environmentally friendly. The unit features a fuel-efficient design capable of running for extended periods, which reduces the frequency of refueling and associated downtime.

The DCA180SSK generator is also engineered for ease of use. It incorporates a user-friendly control panel that provides clear visibility of operational parameters, including voltage output, frequency, and fuel levels. This intuitive interface allows operators to monitor the generator’s performance effortlessly.

Another significant technological advancement in the DCA180SSK is its advanced sound attenuation features. The generator is built within a durable, weather-protective enclosure that minimizes noise levels to enhance worksite safety and compliance with local regulations. This feature not only benefits job sites in urban environments but also improves working conditions for operators and workers alike.

Portability is another key attribute. The DCA180SSK is designed with a compact structure, making it easy to transport and position on-site. The addition of lifting points facilitates quick and safe relocation, while its rugged chassis ensures it can withstand the rigors of construction environments.

This generator also incorporates numerous safety features, including automatic shut-off protocols for low oil pressure and high temperature, enhancing operator safety and extending engine life. With its blend of technology, durability, and user-centric design, the Multiquip DCA180SSK generator provides dependable power for any demanding application, ensuring that work proceeds smoothly, efficiently, and safely.