General Inspection

Prior to each use, the generating set should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel or oil leaks.

Air Cleaner

Every 50 hours: If dust indicator is red, clean the air cleaner element.

Outer Element:

1.Loosen wing bolt, remove dust cup, then remove wing nut and take out element.

2.Clean the inside of the body and cover using a damp cloth.

3.Blow dry with compressed air (0.69Mpa [7kgf.cm2, 99.4 PSI] maximum) against the side of the element along the pleats. Then blow dry against outside along the pleats, then against inside again.

4.Remove one seal each time the element is cleaned.

5.Replace the outer element after cleaning it 6 times or after one year. Replace the outer element if indicator is red even after cleaning it.

6.Check the inner cylinder element clamping nut for looseness, and retighten if necessary.

7.If seal washer is damaged or the threads of wing nut are damaged, replace.

8.Remove evacuator valve and clean it with compressed air. Reinstall.

Inner element (if equipped)

1.Remove the cover and outer element, then remove the inner element.

2.Cover the air connector opening (outer side) with clean cloth or cloth tape.

3.Clean the inside of the body. Remove air connector opening protection.

4.Install a new inner cylinder element to the cylinder and tighten the nut.

5.Install element.

6.After replacing the element, press the button of the dust indicator to return the red piston to its original position.

DCA-400SSK — MAINTENANCE

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations). Always pour through the mesh filter.

Removing Water from the Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally remove the drain cock and drain the contents. During cold weather, the greater the empty volume inside the tank, the easier it is for water to condense. This can be reduced by always keeping the tank as full as possible.

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure.

To restart after running out of fuel, turn the key switch to the “START” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Service Daily

If engine is operating in very dusty and dry grass conditions, a clogged air cleaner will result in high fuel consumption, loss of power and excessive carbon buildup in the combustion chamber.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in diesel. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 28, page 43.

Flushing Out Radiator and Changing Coolant

1.Stop the engine and allow to cool. Tighten valve of the corrosion resistor (if equipped).

2.Turn water filer cap slowly and remove it.

3.Prepare a container to catch the coolant, then open drain plug of the radiator or heat exchanger and drain plug of the engine, and drain the coolant.

4.After draining the coolant, close drain plugs and fill with tap water.

PAGE 54 — DCA-400SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (09/17/01)

Image 54
Contents MQ Power DCA-400SSK DCA-400SSK2 Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Earn Extra Discounts when You order by FAX Parts Ordering ProceduresHigh Temperatures Allow Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneMaintenance Safety TransportingEmergencies Towing Safety Precautions DCA-400SSK -TOWINGDCA-400SSK TRAILER-SAFETY Guidelines Explanation of ChartDCA-400SSK -TRAILER-SPECIFICATIONS WidthModel Coupler Tires Wheels Axle Hubs Suspension Electrical Electric Brake Adjustment BrakesElectric Brakes DCA-400SSK -TRAILER Safety Guidelines Hydraulic/Air/Surge BrakesTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Torque Ft.-Lbs Lug Nut Torque RequirementsDCA-400SSK -TRAILER-WIRING Diagram DCA-400SSK -TRAILER-BRAKETROUBLESHOOTING Symptom Possible Cause SolutionDCA-400SSK -TRAILER-BRAKETROUBLESHOOTING DCA-400SSK Operation and Safety Decals Machine Safety DecalsDCA-400SSK Operation and Safety Decals DCA-400SSK Specifications DCA-400SSK General Information Electronic Governor System Battery ChargerEngine JacketWater Heater OptionalDCA-400SSK Major Components Major ComponentsPage Dry weight 4270kg 9413.64lb Wet weight 4800kg 10582.08 lb DimensionsDCA-400SSK Dimensions Front and Rear DCA-400SSK Control Panel Control PanelDCA-400SSK Control Panel Pilot Lamp Indicates that the generator is working properlyDCA-400SSK Engine Operating Panel Ignition Switch up to S/N3696509 DCA-400SSK Engine Operating PanelDCA-400SSK Outputterminal Panel Overview DCA-400SSK Outputterminal Panel Overview Output Terminal Panel Available Voltages Over Current RelayMaximum Amps How to read the output terminal gauges DCA-400SSK Outputterminal Panel OverviewSingle Phase, 139 Volt Single Phase, 240 VoltPhase, 240 Volt Voltage Change-over BoardSingle Phase, 480 Volt Phase, 480 VoltSingle Phase, 277 Volt DCA-400SSK Installation Outdoor InstallationMounting DCA-400SSK Installation Typical Generator Grounding ApplicationDCA-400SSK PRE-SETUP General Inspection Prior to OperationExtension Cable Lubrication Oil FuelCoolant Operation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt TensionBattery Cable Installation WiringPiping and Hose Connection Single Phase Load Three Phase LoadBefore Starting Engine Before Starting Generator and Control PanelDCA-400SSK Generator START-UP Procedure KEY Switch Engine Ignition Switch Ammeter Load Manual Start-up Auto Start-upDCA-400SSK Generator Shutdown Procedure Engine ShutdownEmergency Stop Page DCA-400SSK Maintenance Check Electric Heater If equipped Changing OilReplacing fuel filter Cleaning breather element GreasingGenerator Storage Inspection / Maintenance DCA-400SSK Generator Wiring Diagram Page DCA-400SSK Engine Wiring Diagram KEY Switch DCA-400SSK Engine Wiring Diagram Controller DCA-400SSK -TROUBLESHOOTING Engine DCA-400SSK -TROUBLESHOOTING Engine DCA-400SSK -TROUBLESHOOTING GENERATOR/ENGINE Generator TroubleshootingDCA-400SSK -TROUBLESHOOTING Engine Controller Explanation of Code in Remarks Column Items Found In the Items Number ColumnDCA-400SSK Suggested Spare Parts Qty DescriptionDCA-400SSK Generator Assy Part Name QTY DCA-400SSK Generator Assy COVER, Bearing DCA-400SSK Control BOX Assy DCA-400SSK Control BOX Assy Part Name QTY RemarksDCA-400SSK Control BOX Assy RA20A2SE102BJ 2W 1K OHM DCA-400SSK Engine & Radiator Assy Dust Sensor DCA-400SSK Engine & Radiator Assy DCA-400SSK Engine & Radiator Assy DCA-400SSKENGINE Operating Panel Assy UP to S/N 3701677~DCA-400SSK Engine Operating Panel Assy DCA-400SSK Outputterminal Assy DCA-400SSK Output Terminal Assy DCA-400SSK Battery Assy Battery DCA-400SSK Actuator Assy DYNC11020300024 DCA-400SSK Muffler Assy Muffler DCA-400SSK Fuel Tank Assy Fuel Tank DCA-400SSK Enclosure #1 Assy Floor Panel DCA-400SSK Enclosure #1 Assy Filler Bracket DCA-400SSK Enclosure #2 Assy Enclosure #2 AssyRear Frame DCA-400SSK Enclosure #2 Assy COVER, Roof Panel DCA-400SSK Enclosure #3 Assy Enclosure #3 AssySide Panel DCA-400SSK Enclosure #3 Assy 0845046904 DCA-400SSK Rubber Seal Assy Rubber Seal Assy DCA-400SSK OIL Piping Assy Pump DCA-400SSK Name Plate and Decals N3701677~Control BOX Group Bonnet Group Battery Group Engine and Radiator Group DCA-400SSK Name Plate and Decals Output Terminal GroupEffective July 1 Page Mail mq@multiquip.com WWW multiquip.com

DCA-400SSK specifications

The Multiquip DCA-400SSK is a robust solution designed for a variety of construction and developmental applications. Known for its reliability and efficiency, this three-phase diesel generator is equipped with a powerful engine that offers dependable performance in the field.

One of the standout features of the DCA-400SSK is its 400 kW output capacity, making it an ideal choice for large-scale operations where consistent power supply is crucial. It is powered by a high-performance, durable diesel engine that meets stringent emissions standards, ensuring compliance while delivering high efficiency.

The DCA-400SSK comes equipped with advanced technology that enhances its usability and performance. Its automatic voltage regulation (AVR) system ensures stable voltage under varying load conditions, which is essential for sensitive electrical equipment. This feature provides peace of mind to operators, knowing that their equipment is protected from voltage fluctuations.

Built with a sound-attenuated enclosure, the DCA-400SSK is designed to minimize noise, making it suitable for operation in noise-sensitive environments. This aspect not only protects the hearing of those working nearby but also ensures compliance with local noise regulations, thereby promoting a safer working environment.

Another remarkable characteristic of the DCA-400SSK is its user-friendly control panel, which features easy-to-read gauges and straightforward controls. This makes monitoring and operating the generator simple, even for those with limited experience in generator operation. With remote start capabilities, users can start and stop the generator from a distance, enhancing efficiency and convenience.

In terms of mobility, the DCA-400SSK is designed with integrated lifting points and forklift pockets, which facilitate easy transport around job sites. Its rugged construction ensures durability, able to withstand the harsh conditions typical of construction sites while maintaining optimal performance.

Overall, the Multiquip DCA-400SSK stands as a reliable and efficient diesel generator, combining powerful output with advanced features and environmental considerations. It is tailored to meet the demands of contractors and operators looking for a versatile and sturdy power solution. Whether for temporary power needs or long-term projects, the DCA-400SSK delivers exceptional performance in a compact and user-friendly package.