Multiquip DCA-400SSK Check Electric Heater If equipped, Changing Oil, Replacing fuel filter

Page 55

5.When the water level is near the mouth of the water filler, open drain plugs and start the engine, and run at low idling. Keep the engine running at low idling and flush the radiator for about 10 minutes.

6.Adjust the flow of the water flowing in and draining out to ensure that the radiator is always full during the flushing operation, While flushing water through the system, watch carefully the water inlet hose does not come out of the radiator filler port.

7.After flushing, stop the engine, open drain plug and drain the water, then close drain plugs.

8.After draining the water, flush the system with a flushing agent. See instructions on flushing agent label.

9.After flushing, open drain plugs and drain out all the water, then close drain plugs and add tap water so the water level is near the mouth of the water filler.

10.When the water level is near the mouth of the water filler, open drain plugs and start the engine, run at low idling and continue to flush the system until clean water comes out. Adjust the flow of the water flowing in and draining out to ensure the radiator is always full during the flushing operation.

11.When clean water comes out, stop the engine, drain all the water, then close drain plugs.

12.Remove the corrosion resistor (if equipped) and open valve.

13.Supply water until it flows over the water filler.

14.Drain the water inside reserve tank, clean the inside of the reserve tank, then fill with coolant/water mixture to between the full and low lines.

15.Stop the engine, wait for 3 minutes, add tap water until the water level reaches near the water filer port, then tighten the radiator cap.

Check Electric Heater (If equipped)

Before starting in cold weather (once a year), please contact your Komatsu distributor for inspection. Remove electric heater from the engine intake manifold and check for disconnections or dirt. When checking or installing the electric heater, replace the gasket with a new part.

DCA-400SSK — MAINTENANCE

Changing Oil

1.Make sure the oil is cool before changing.

2.Set a container directly under the drain plug of the oil pan. Loosen the drain plug slowly.

3.Check the drained oil for excessive metal particles or foreign material. Contact the distributor if there is metal particles or foreign material.

4.Using a filter wrench, turn filter cartridge to the left to remove it. If the filter cartridge is filled with a large amount of oil, wait 10 minutes or so before removing. Make sure there is no old gasket stuck on the filter holder.

5.Tighten drain plug. Clean the filter holder, fill the new filter cartridge with clean engine oil, coat the packing and thread of the new filter cartridge with engine oil, then install it to the filter holder. Tighten until the gasket surface contacts the seal surface of the filter holder, then tighten it a further 3/4 to 1 turn.

6.Add engine oil through oil filler until the oil level is between the H and L marks on the dipstick.

7.Run the engine at idling for a short time, then stop the engine. Recheck the oil level and fill as necessary.

Replacing fuel filter

1.Set the container under the filter cartridge to catch fuel.

2.Using a filter wrench, turn the filter cartridge to the left to remove it.

3.Clean the filter holder, fill the new filter cartridge with fuel, coat the packing surface of the filter cartridge with engine oil, then install the cartridge to the filter holder.

4.When installing, tighten until the packing surface contacts the seal surface of the filter holder then tighten a further 2/3 of a turn. If the filter cartridge is tighten too much, the packing will be damaged and will cause fuel leakage. Fuel leakage will occur if the filter cartridge is not tightened enough. Always tighten to the correct angle.

5.After replacing filter cartridge, loosen air bleed plug.

6.Loosen the knob of feed pump, and pump it up and down until no bubbles come our with the fuel from air bleed plug.

DCA-400SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (09/17/01) — PAGE 55

Image 55
Contents MQ Power DCA-400SSK DCA-400SSK2 Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures Earn Extra Discounts when You order by FAXRules for Safe Operation High Temperatures AllowRadiator Rules for Safe OperationLoading and Unloading Crane BatteryTransporting Maintenance SafetyEmergencies DCA-400SSK -TOWING Towing Safety PrecautionsExplanation of Chart DCA-400SSK TRAILER-SAFETY GuidelinesWidth DCA-400SSK -TRAILER-SPECIFICATIONSModel Coupler Tires Wheels Axle Hubs Suspension Electrical Brakes Electric Brake AdjustmentElectric Brakes Hydraulic/Air/Surge Brakes DCA-400SSK -TRAILER Safety GuidelinesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements Torque Ft.-LbsDCA-400SSK -TRAILER-WIRING Diagram Symptom Possible Cause Solution DCA-400SSK -TRAILER-BRAKETROUBLESHOOTINGDCA-400SSK -TRAILER-BRAKETROUBLESHOOTING Machine Safety Decals DCA-400SSK Operation and Safety DecalsDCA-400SSK Operation and Safety Decals DCA-400SSK Specifications DCA-400SSK General Information JacketWater Heater Optional Battery ChargerEngine Electronic Governor SystemMajor Components DCA-400SSK Major ComponentsPage Dimensions Dry weight 4270kg 9413.64lb Wet weight 4800kg 10582.08 lbDCA-400SSK Dimensions Front and Rear Control Panel DCA-400SSK Control PanelPilot Lamp Indicates that the generator is working properly DCA-400SSK Control PanelDCA-400SSK Engine Operating Panel DCA-400SSK Engine Operating Panel Ignition Switch up to S/N3696509DCA-400SSK Outputterminal Panel Overview DCA-400SSK Outputterminal Panel Overview Over Current Relay Output Terminal Panel Available VoltagesMaximum Amps DCA-400SSK Outputterminal Panel Overview How to read the output terminal gaugesVoltage Change-over Board Single Phase, 240 VoltPhase, 240 Volt Single Phase, 139 VoltPhase, 480 Volt Single Phase, 480 VoltSingle Phase, 277 Volt Outdoor Installation DCA-400SSK InstallationMounting Typical Generator Grounding Application DCA-400SSK InstallationGeneral Inspection Prior to Operation DCA-400SSK PRE-SETUPExtension Cable Fuel Lubrication OilCoolant Fan Belt Tension Cleaning the RadiatorAir Cleaner Operation in Freezing WeatherWiring Battery Cable InstallationPiping and Hose Connection Three Phase Load Single Phase LoadBefore Starting Generator and Control Panel Before Starting EngineDCA-400SSK Generator START-UP Procedure KEY Switch Engine Ignition Switch Ammeter Load Auto Start-up Manual Start-upEngine Shutdown DCA-400SSK Generator Shutdown ProcedureEmergency Stop Page DCA-400SSK Maintenance Changing Oil Check Electric Heater If equippedReplacing fuel filter Greasing Cleaning breather elementGenerator Storage Inspection / Maintenance DCA-400SSK Generator Wiring Diagram Page DCA-400SSK Engine Wiring Diagram KEY Switch DCA-400SSK Engine Wiring Diagram Controller DCA-400SSK -TROUBLESHOOTING Engine DCA-400SSK -TROUBLESHOOTING Engine Generator Troubleshooting DCA-400SSK -TROUBLESHOOTING GENERATOR/ENGINEDCA-400SSK -TROUBLESHOOTING Engine Controller Items Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description DCA-400SSK Suggested Spare PartsDCA-400SSK Generator Assy Part Name QTY DCA-400SSK Generator Assy COVER, Bearing DCA-400SSK Control BOX Assy Part Name QTY Remarks DCA-400SSK Control BOX AssyDCA-400SSK Control BOX Assy RA20A2SE102BJ 2W 1K OHM DCA-400SSK Engine & Radiator Assy Dust Sensor DCA-400SSK Engine & Radiator Assy DCA-400SSK Engine & Radiator Assy UP to S/N 3701677~ DCA-400SSKENGINE Operating Panel AssyDCA-400SSK Engine Operating Panel Assy DCA-400SSK Outputterminal Assy DCA-400SSK Output Terminal Assy DCA-400SSK Battery Assy Battery DCA-400SSK Actuator Assy DYNC11020300024 DCA-400SSK Muffler Assy Muffler DCA-400SSK Fuel Tank Assy Fuel Tank DCA-400SSK Enclosure #1 Assy Floor Panel DCA-400SSK Enclosure #1 Assy Filler Bracket Enclosure #2 Assy DCA-400SSK Enclosure #2 AssyRear Frame DCA-400SSK Enclosure #2 Assy COVER, Roof Panel Enclosure #3 Assy DCA-400SSK Enclosure #3 AssySide Panel DCA-400SSK Enclosure #3 Assy 0845046904 DCA-400SSK Rubber Seal Assy Rubber Seal Assy DCA-400SSK OIL Piping Assy Pump N3701677~ DCA-400SSK Name Plate and DecalsControl BOX Group Bonnet Group Battery Group Engine and Radiator Group Output Terminal Group DCA-400SSK Name Plate and DecalsEffective July 1 Page Mail mq@multiquip.com WWW multiquip.com

DCA-400SSK specifications

The Multiquip DCA-400SSK is a robust solution designed for a variety of construction and developmental applications. Known for its reliability and efficiency, this three-phase diesel generator is equipped with a powerful engine that offers dependable performance in the field.

One of the standout features of the DCA-400SSK is its 400 kW output capacity, making it an ideal choice for large-scale operations where consistent power supply is crucial. It is powered by a high-performance, durable diesel engine that meets stringent emissions standards, ensuring compliance while delivering high efficiency.

The DCA-400SSK comes equipped with advanced technology that enhances its usability and performance. Its automatic voltage regulation (AVR) system ensures stable voltage under varying load conditions, which is essential for sensitive electrical equipment. This feature provides peace of mind to operators, knowing that their equipment is protected from voltage fluctuations.

Built with a sound-attenuated enclosure, the DCA-400SSK is designed to minimize noise, making it suitable for operation in noise-sensitive environments. This aspect not only protects the hearing of those working nearby but also ensures compliance with local noise regulations, thereby promoting a safer working environment.

Another remarkable characteristic of the DCA-400SSK is its user-friendly control panel, which features easy-to-read gauges and straightforward controls. This makes monitoring and operating the generator simple, even for those with limited experience in generator operation. With remote start capabilities, users can start and stop the generator from a distance, enhancing efficiency and convenience.

In terms of mobility, the DCA-400SSK is designed with integrated lifting points and forklift pockets, which facilitate easy transport around job sites. Its rugged construction ensures durability, able to withstand the harsh conditions typical of construction sites while maintaining optimal performance.

Overall, the Multiquip DCA-400SSK stands as a reliable and efficient diesel generator, combining powerful output with advanced features and environmental considerations. It is tailored to meet the demands of contractors and operators looking for a versatile and sturdy power solution. Whether for temporary power needs or long-term projects, the DCA-400SSK delivers exceptional performance in a compact and user-friendly package.