DCA-400SSK FAMILIARIZATION

Generator

The MQ Power Model DCA-400SSK is a 320 kW generator that is designed as a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.

Engine Control Panel

The “Engine Control Panel” is provided with the following:

zAuto/Start/Stop Controller (S/N 3696510~)

zTachometer

zWater Temperature Gauge

zOil Pressure Gauge

zCharging Ammeter Gauge

zEngine Warning Lamp Module

zEngine Speed Switch (S/N3701667~)

zPre-Heat Button

zPre-Heat Lamp

zEmergency Stop Button

zBattery Switch

zStarter Switch (Up to S/N3696509)

Generator Control Panel

The “Generator Control Panel” is provided with the following:

zOutput Voltage Adjustment Knob

zFrequency Meter (Hz)

zAC Ammeter (Amps)

zAC Voltmeter (Volts)

zAmmeter Change-Over Switch

zVoltmeter Change-Over Switch

zPanel Light

zAuto On/Off Engine Controller

zPanel Light Switch

zPilot Lamp

Output Terminal Panel

The “Output Terminal Panel” is provided with the following:

zThree120/240V output receptacles, 50 amp

zTwo 120V receptacles, 20 amp

z3 Circuit Breakers 240V @50 amps

z2 GFCI Circuit Breakers 125V@ 20amps

Control Box

The “Control Box” is provided with the following:

zMain Circuit Breaker 1060 amps

zOver-Current Relay

zHigh Idle Adjust Trimmer

zCurrent Transformer

zAutomatic Voltage Regulator

Open Delta Excitation System

The DCA-400SSK generator is equipped with the state of the art "Open-Delta" excitation system. The open delta system consist of an electrically independent winding wound among stationary windings of the AC output section.

There are four leads: A, B, C and D. During light loads, the power to the Automatic Voltage Regulator (AVR) is supplied from the leads parallel connections of B&C. When loads increase, the AVR switches and accepts power from leads A&D. The output of leads A&D increase proportionally with load. This of adding the voltages to each phase provides better voltage response during heavy loads.

The connections of the AVR to the AC output windings are for sensing only. No power is required from these windings.

The open-delta design provides virtually unlimited excitation current, offering maximum motor starting capabilities. The excitation does not have a "fixed ceiling" and responds according the demands of the required load.

Engine Controller Alarm System

The DCA-400SSK generator is equipped with various alarms and LED status indicators.These alarms and status indicators are provided to add safety to the generator when operating under normal conditions. The DCA-400SSK generator is designed to shutdown in the event of low oil, high coolant temperature, low battery and other operation conditions that may cause severe damage to the generator.

PAGE 24 — DCA-400SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (09/17/01)

Image 24
Contents MQ Power DCA-400SSK DCA-400SSK2 Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Earn Extra Discounts when You order by FAX Parts Ordering ProceduresHigh Temperatures Allow Rules for Safe OperationRules for Safe Operation RadiatorBattery Loading and Unloading CraneMaintenance Safety TransportingEmergencies Towing Safety Precautions DCA-400SSK -TOWINGDCA-400SSK TRAILER-SAFETY Guidelines Explanation of ChartDCA-400SSK -TRAILER-SPECIFICATIONS WidthModel Coupler Tires Wheels Axle Hubs Suspension Electrical Electric Brake Adjustment BrakesElectric Brakes DCA-400SSK -TRAILER Safety Guidelines Hydraulic/Air/Surge BrakesTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Torque Ft.-Lbs Lug Nut Torque RequirementsDCA-400SSK -TRAILER-WIRING Diagram DCA-400SSK -TRAILER-BRAKETROUBLESHOOTING Symptom Possible Cause SolutionDCA-400SSK -TRAILER-BRAKETROUBLESHOOTING DCA-400SSK Operation and Safety Decals Machine Safety DecalsDCA-400SSK Operation and Safety Decals DCA-400SSK Specifications DCA-400SSK General Information Battery Charger EngineElectronic Governor System JacketWater Heater OptionalDCA-400SSK Major Components Major ComponentsPage Dry weight 4270kg 9413.64lb Wet weight 4800kg 10582.08 lb DimensionsDCA-400SSK Dimensions Front and Rear DCA-400SSK Control Panel Control PanelDCA-400SSK Control Panel Pilot Lamp Indicates that the generator is working properlyDCA-400SSK Engine Operating Panel Ignition Switch up to S/N3696509 DCA-400SSK Engine Operating PanelDCA-400SSK Outputterminal Panel Overview DCA-400SSK Outputterminal Panel Overview Output Terminal Panel Available Voltages Over Current RelayMaximum Amps How to read the output terminal gauges DCA-400SSK Outputterminal Panel OverviewSingle Phase, 240 Volt Phase, 240 VoltSingle Phase, 139 Volt Voltage Change-over BoardSingle Phase, 480 Volt Phase, 480 VoltSingle Phase, 277 Volt DCA-400SSK Installation Outdoor InstallationMounting DCA-400SSK Installation Typical Generator Grounding ApplicationDCA-400SSK PRE-SETUP General Inspection Prior to OperationExtension Cable Lubrication Oil FuelCoolant Cleaning the Radiator Air CleanerOperation in Freezing Weather Fan Belt TensionBattery Cable Installation WiringPiping and Hose Connection Single Phase Load Three Phase LoadBefore Starting Engine Before Starting Generator and Control PanelDCA-400SSK Generator START-UP Procedure KEY Switch Engine Ignition Switch Ammeter Load Manual Start-up Auto Start-upDCA-400SSK Generator Shutdown Procedure Engine ShutdownEmergency Stop Page DCA-400SSK Maintenance Check Electric Heater If equipped Changing OilReplacing fuel filter Cleaning breather element GreasingGenerator Storage Inspection / Maintenance DCA-400SSK Generator Wiring Diagram Page DCA-400SSK Engine Wiring Diagram KEY Switch DCA-400SSK Engine Wiring Diagram Controller DCA-400SSK -TROUBLESHOOTING Engine DCA-400SSK -TROUBLESHOOTING Engine DCA-400SSK -TROUBLESHOOTING GENERATOR/ENGINE Generator TroubleshootingDCA-400SSK -TROUBLESHOOTING Engine Controller Explanation of Code in Remarks Column Items Found In the Items Number ColumnDCA-400SSK Suggested Spare Parts Qty DescriptionDCA-400SSK Generator Assy Part Name QTY DCA-400SSK Generator Assy COVER, Bearing DCA-400SSK Control BOX Assy DCA-400SSK Control BOX Assy Part Name QTY RemarksDCA-400SSK Control BOX Assy RA20A2SE102BJ 2W 1K OHM DCA-400SSK Engine & Radiator Assy Dust Sensor DCA-400SSK Engine & Radiator Assy DCA-400SSK Engine & Radiator Assy DCA-400SSKENGINE Operating Panel Assy UP to S/N 3701677~DCA-400SSK Engine Operating Panel Assy DCA-400SSK Outputterminal Assy DCA-400SSK Output Terminal Assy DCA-400SSK Battery Assy Battery DCA-400SSK Actuator Assy DYNC11020300024 DCA-400SSK Muffler Assy Muffler DCA-400SSK Fuel Tank Assy Fuel Tank DCA-400SSK Enclosure #1 Assy Floor Panel DCA-400SSK Enclosure #1 Assy Filler Bracket DCA-400SSK Enclosure #2 Assy Enclosure #2 AssyRear Frame DCA-400SSK Enclosure #2 Assy COVER, Roof Panel DCA-400SSK Enclosure #3 Assy Enclosure #3 AssySide Panel DCA-400SSK Enclosure #3 Assy 0845046904 DCA-400SSK Rubber Seal Assy Rubber Seal Assy DCA-400SSK OIL Piping Assy Pump DCA-400SSK Name Plate and Decals N3701677~Control BOX Group Bonnet Group Battery Group Engine and Radiator Group DCA-400SSK Name Plate and Decals Output Terminal GroupEffective July 1 Page Mail mq@multiquip.com WWW multiquip.com

DCA-400SSK specifications

The Multiquip DCA-400SSK is a robust solution designed for a variety of construction and developmental applications. Known for its reliability and efficiency, this three-phase diesel generator is equipped with a powerful engine that offers dependable performance in the field.

One of the standout features of the DCA-400SSK is its 400 kW output capacity, making it an ideal choice for large-scale operations where consistent power supply is crucial. It is powered by a high-performance, durable diesel engine that meets stringent emissions standards, ensuring compliance while delivering high efficiency.

The DCA-400SSK comes equipped with advanced technology that enhances its usability and performance. Its automatic voltage regulation (AVR) system ensures stable voltage under varying load conditions, which is essential for sensitive electrical equipment. This feature provides peace of mind to operators, knowing that their equipment is protected from voltage fluctuations.

Built with a sound-attenuated enclosure, the DCA-400SSK is designed to minimize noise, making it suitable for operation in noise-sensitive environments. This aspect not only protects the hearing of those working nearby but also ensures compliance with local noise regulations, thereby promoting a safer working environment.

Another remarkable characteristic of the DCA-400SSK is its user-friendly control panel, which features easy-to-read gauges and straightforward controls. This makes monitoring and operating the generator simple, even for those with limited experience in generator operation. With remote start capabilities, users can start and stop the generator from a distance, enhancing efficiency and convenience.

In terms of mobility, the DCA-400SSK is designed with integrated lifting points and forklift pockets, which facilitate easy transport around job sites. Its rugged construction ensures durability, able to withstand the harsh conditions typical of construction sites while maintaining optimal performance.

Overall, the Multiquip DCA-400SSK stands as a reliable and efficient diesel generator, combining powerful output with advanced features and environmental considerations. It is tailored to meet the demands of contractors and operators looking for a versatile and sturdy power solution. Whether for temporary power needs or long-term projects, the DCA-400SSK delivers exceptional performance in a compact and user-friendly package.