Kohler 1198326-2-A manual Installation Instructions, Product Information, Electrical Requirements

Page 2

Installation Instructions

WARNING: When using electrical products, basic precautions should always be followed, including the following:

DANGER: Risk of electric shock. Connect only to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI)*.

Building materials and wiring should be routed away from the blower body and other heat-producing components of the unit.

Install to permit access for servicing.

A pressure wire connector marked ″Earth/Ground″ is provided within the wiring compartment. To reduce the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply panel with copper wire equivalent in size to the circuit conductor supplying this equipment.

Pressure wire connectors are provided on the exterior of the junction box, blower or control within this unit to permit connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as needed to comply with local requirements.

Grounding is required. The unit should be installed by a qualified service representative, and grounded.

WARNING: Risk of injury or property damage. Please read all instructions thoroughly before beginning installation, including the following requirements.

WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.

WARNING: Risk of electric shock. Disconnect power before servicing.

NOTICE: Follow all local plumbing and electrical codes. In Canada, install this unit in accordance with the Canadian Electrical Code, Part 1.

*Outside North America, this device may be known as a Residual Current Device (RCD).

Product Information

Electrical Requirements

The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). The GFCI or RCD protect against line-to-ground shock hazard. Use a 120 V, 15 A, 60 Hz dedicated

service for the bath.

If the blower supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Product Notices

NOTICE: Keep the area around the blower clean and free of debris. Ensure that the area around the blower is free of sawdust, insulation, dirt, and other small loose debris. Such material can block the blower air ducts and reduce the air flow through the blower.

NOTICE: This product contains an automatic water purge mode that turns the blower on for two minutes about 30 minutes after the unit is turned off and drained.

Features

Factory installed components include a blower motor with power supply cord, check valve, air piping, and user keypad. Other than electrical wiring and plumbing, no assembly is needed.

1198326-2-A

2

Kohler Co.

Image 2
Contents Installation and Care Guide Product Information Installation InstructionsProduct Notices Features Electrical RequirementsTools and Materials LevelPrepare the Site Option 2 Using a Cement or Mortar Bed Install the BathOption 1 Install Using Construction Adhesive Install the PlumbingInstall the Bath Make the Electrical Connections USA Clean-up After Installation Complete the InstallationFinish the Installation Make the Electrical Connections CanadaImportant Safety Instructions Complete the InstallationImportant Safety Instructions Care and Cleaning Operating InstructionsMaintaining the Airjets WarrantyFor Mexico Troubleshooting WarrantyTroubleshooting Information sur le produit Instructions d’installationInstallations électriques requises Information sur le produit Outils et matériauxCaractéristiques Préparer le site Fixer les brides de cloutage en place dispositifs en alcôve Installer la baignoireOption 2 Utilisation de lit de ciment ou de mortier Installer la baignoire Installer la plomberieEffectuer les connexions électriques États-Unis Effectuer les connexions électriques Canada Terminer l’installationTerminer l’installation Tester le fonctionnement de la baignoireNettoyer après l’installation Instructions Importantes sur la sécuritéInstructions Importantes sur la sécurité Instructions d’utilisation Entretien et nettoyageGarantie Nettoyer le clavier utilisateur et la télécommandeMaintenance des jets d’air DépannageSymptômes Causes probables Action recommandée DépannageKohler Co Français-13 1198326-2-A Requisitos eléctricos Instrucciones de instalaciónInformación sobre el producto Características Herramientas y materialesAvisos sobre el producto Información sobre el productoPrepare el sitio Opción 2 Instale utilizando una capa de cemento o mortero Instale la bañeraOpción 1 Instale utilizando adhesivo de construcción Instale la bañera Instale la plomeríaRealice las conexiones eléctricas EE.UU Pruebe el funcionamiento de la bañera Realice las conexiones eléctricas CanadáTermine la instalación Acabe la instalaciónInstrucciones importantes de seguridad Termine la instalación Limpieza después de la instalaciónInstrucciones importantes de seguridad Instrucciones de funcionamiento Cuidado y limpiezaCuidado y limpieza GarantíaPara México Limpieza del teclado y del control remotoGuía para resolver problemas GarantíaGuía para resolver problemas Síntomas Causas probables Acción recomendadaKohler Co Español-14 1198326-2-A 1198326-2-A 1198326-2-A Kohler Co