Generac Power Systems 005040-2 Panel Bracket, Ctrl PNL Support 2.5L Ford, Washer Lock M6-1/4

Page 37

 

 

 

 

Section 8 - Exploded Views and Parts

 

 

 

 

 

 

 

 

 

 

 

 

Guardian Liquid-cooled 25 kW Generator

 

 

 

 

 

 

Mounting Base — Drawing No. 0E9964-E

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

 

1

0D9336

3

PANEL BRACKET

 

 

2

0E9939

2

CTRL PNL SUPPORT 2.5L FORD

 

 

3

0C2454

24

SCREW TH-FRM M6-1 X 16 N WA Z/JS

 

 

4

049813

1

NUT HEX M6 X 1.0 G8 YEL CHR

 

 

5

022097

1

WASHER LOCK M6-1/4

 

 

6

026850

2

WASHER SHAKEPROOF EXT 1/4 STL

 

 

7

055414

1

LUG SLDLSS #2-#8 X 17/64 CU

 

 

8

022473

1

WASHER FLAT 1/4-M6 ZINC

 

 

9

047411

1

SCREW HHC M6-1.0 X 16 G8.8

 

 

10

052860

4

NUT FLANGED HEX M12-1.75

 

 

11

052251

4

DAMPENER VIBRATION 40 BLUE

 

 

12

052257

4

SPACER .49 X .62 X 1.87 PWDR/ZNC

 

 

13

052252

4

DAMPENER VIBRATION

 

 

14

052259

4

WASHER FLAT M12

 

 

15

052891

4

SCREW HHC M12-1.75 X 80 G8.8

 

 

16

0536210261

1

ASSY WIRE #0 12.00"

 

 

17

074906

1

SCREW HHTT M6-1.0 X 20 BP

 

 

18

077483

REF

BATT 12VDC 75-AH 26 (NOT SHOWN)

 

 

19

0E9941

1

HOLD DOWN BATTERY 2.5L FORD

 

 

20

025507

3

WASHER SHAKEPROOF EXT 7/16 STL

 

 

21

059980

1

SCREW HHC M10-1.5 X 25 G10.9

 

 

22

046526

1

WASHER LOCK M10

 

 

23

022131

1

WASHER FLAT 3/8-M10 ZINC

 

 

24

021991

1

EARTH STRAP

 

 

25

038805J

1

CABLE BATT BLK #1 X 30.00

 

 

26

050331

REF

BATTERY POST COVER (BLACK)

 

 

27

050331A

REF

BATTERY POST COVER (RED)

 

 

28

038804J

1

CABLE BATT RED #1 X 40.50

 

 

29

045771

REF

NUT HEX M8-1.25 G8 YEL CHR

 

 

30

022129

REF

WASHER LOCK M8-5/16

 

 

31

027482

1

WASHER SHAKEPROOF EXT 5/16 STL

 

 

32

075763

1

BOOT BATTERY CABLE

 

 

33

0E9748

1

ASSY MTG BASE 2.5L FORD

 

 

34

0E9940

1

TRAY BATTERY 2.5L FORD

 

 

35

065852

1

SPRING CLIP HOLDER .37-.62

 

 

36

024469

1

SCREW HHTT #10-32 X 3/8 CZ

 

 

Generac® Power Systems, Inc. 35

Image 37
Contents This manual should remain with the unit ‹ Operation and Maintenance Authorized Service Dealer Location‹ HOW to Obtain Service IntroductionTable of Contents General Hazards ‹ Standards Index Fire HazardsGenerator Transfer SwitchAutomatic System Operation Generator AC Connection Systems‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.3 LOW Coolant Level Switch Generator Fuel SystemUnpacking SpecificationsLifting the Generator Engine OIL Recommendations Fuel Consumption‹ 1.10.2 Generator Coolant Recommendations Before Installation‹ 2.1.1 Nfpa Standards Generator Location Basic Standby Electric SystemGenerator Mounting Support Emergency Circuit Isolation MethodTotal Circuit Isolation Method Using AN Engineered GTS Transfer SwitchGenerator AC Neutral Connections Grounding the GeneratorPreparation Before START-UP Battery Installation‹ 2.10.1 Vented Batteries Engineered GTS Transfer Switch ‹ 3.2.1 AUTO/OFF/MANUAL Switch ‹ 3.2.2 Fault Indicator Leds‹ 3.2.5 SET Exercise Time Switch Control Console Components‹ 3.2.6 System Ready LED Manual Transfer START-UP Engine Governor AdjustmentsWeekly Exercise Cycle Automatic OperationRetransfer and Shutdown Control Board DIP Switch Settings Intake Manifold Procedure Exhaust Manifold ProcedureCylinder Head Procedure Cooling SystemChecking Fluid Levels Overload Protection for Engine DC Electrical System‹ 4.8.8 Check FAN Belt ‹ 4.8.11 Changing the Engine AIR Cleaner‹ 4.8.9 Inspect Engine Governor ‹ 4.8.10 Changing Engine OIL‹ 4.9.1 Cleaning the Generator Miscellaneous Maintenance‹ 4.9.3 Battery Maintenance ‹ 4.9.4 Battery ReplacementService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsGuardian Liquid-cooled 25 kW Generator Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Mount Battery Post Cover Black Hold Down Battery 2.5L FordBattery Post Cover RED Boot Battery CablePanel for Access Assembly Cover Access Assy Wire 14AWG 7.5 #0 GRN/YELCover Access GEN Roof ACO & STD Encl 2.5L54 36 Switch ROC Dpst 125V SPD Assy 2A 12V UL BatteryAssy Wire Fuse Holder Screw Hhtt M5-0.8 X 12 BPGenerac Power Systems, Inc Ctrl PNL TOP 2.5L Ford STL Only Motor Units Engine 2.5L Ford Tank Coolant RecoverySTARTER, 12 Volt NUT HEX M10-1.5 G8 YEL CHRTo Engine Cover AIR Cleaner Body Carburetor AssemblyGASKET, AIR Cleaner Adapter Bracket Fuel RegulatorLocktight Rotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 25KW 1P Direct HSB 2.5L Ford Rotor 39030AD1 HSB TecumPipe Exhaust 2.5L Ford Pipe Muffler OUTMuffler 2.5L Ford Saddle 2 InchCover Connector Housing Housing Governor ConnectorASM Motor Stepper Harn GOV 2.5L FordRADIATOR, 2.5L Ford Support Radiator 2.5L AL TALHOSE, 2.5L Ford Lower VENTURI, 16 FAN 2.5L Ford RadiatorInstallation Diagram MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule