TDB3108, WF3208 Terreon® 54" Circular | Installation |
6
Electrical connections for Adaptive Infrared
CONNECT THE THREE WIRES FROM THE INFRARED MODULE ASSEMBLY TO THE VALVE ASSEMBLY. ATTACH TWO OF THE FEMALE A CONNECT WIRES TO THE SOLENOIDS AS SHOWN IN FIGURE 12. ATTACH THE MALE CONNECT WIRE TO ONE OF THE 24 VAC
TRANSFORMER LEADS. ATTACH THE REMAINING TRANSFORMER LEAD TO THE SOLENOID WIRE ADAPTER (SEE FIGURE 12).
B CONNECT 24 VAC TRANSFORMER PROVIDED TO POWER SOURCE.
C TURN SUPPLIES ON. OPEN CHECK/STOP VALVES COMPLETELY.
D OPEN VOLUME CONTROL VALVE COMPLETELY AND CHECK PIPING INSTALLATION FOR LEAKS.
E PASS YOUR HAND IN FRONT OF EACH SENSOR UNTIL AIR IS PURGED FROM THE LINES.
I.R. MODULE
WINDOW
TOP VIEW MODULE | ||
RED | ASSEMBLY | |
BLACK |
| CONNECT WIRES |
|
| AS SHOWN |
RED
VALVE ASSY.
110/24 VAC TRANSFORMER
WIRE |
|
| |
ADAPTER |
|
| |
F = FEMALE CONNECT | |||
Figure 12 | M = MALE CONNECT | ||
|
18 | 4/6/2007 | Bradley Corporation • |