Specifications and Dimensions
Specification |
| 20 | 30 | 40 | 60 | 80 | 125 | |
|
|
|
|
|
|
|
| |
Cylinder Speeds |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Gentle wash/reverse speed, RPM |
| 29 | 27 | 26 | 26 | 22 | 26 | |
|
|
|
|
|
|
|
| |
Wash/reverse speed, RPM |
| 52 | 52 | 46 | 43 | 40 | 37 | |
|
|
|
|
|
|
|
| |
Distribution speed, RPM |
| 92 | 92 | 82 | 77 | 70 | 65 | |
|
|
|
|
|
|
|
| |
Low extract speed, RPM |
| 366 | 366 | 328 | 307 | 280 | 260 | |
|
|
|
|
|
|
| ||
Medium extract speed, RPM (Not | 534 | 534 | 478 | 447 | 408 | 378 | ||
available on Electronic Control models) |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
High extract speed, RPM |
| 686 | 686 | 613 | 574 | 524 | 485 | |
|
|
|
|
|
|
|
| |
Centrifugal Force Data |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Gentle wash centrifugal force, G |
| 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.43 | |
|
|
|
|
|
|
|
| |
Wash/reverse centrifugal force, G |
| 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | |
|
|
|
|
|
|
|
| |
Distribution centrifugal force, G |
| 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.6 | |
|
|
|
|
|
|
|
| |
Extract Speed 1 |
| 60 | 60 | 60 | 60 | 60 | 60 | |
|
|
|
|
|
|
|
| |
Extract Speed 2 |
| 80 | 80 | 80 | 80 | 80 | 80 | |
|
|
|
|
|
|
|
| |
Extract Speed 3 |
| 100 | 100 | 100 | 100 | 100 | 100 | |
|
|
|
|
|
|
| ||
Extract Speed 4 | 120 | 120 | 120 | 120 | 120 | 120 | ||
|
|
|
|
|
|
| ||
Extract Speed 5 | 140 | 140 | 140 | 140 | 140 | 140 | ||
|
|
|
|
|
|
| ||
Direct Steam Heating (Optional) |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Steam inlet connection size, NPT |
| N/A | N/A | 1/2 | 1/2 | 1/2 | 3/4 | |
|
|
|
|
|
|
|
| |
Number of steam inlets |
| N/A | N/A | 1 | 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
Steam required to raise bath |
| LOW | N/A | N/A | 2.09 | 3.6 | 2.58 | 3.64 |
water temperature |
| (0.94) | (1.63) | (1.17) | (1.65) | |||
|
|
|
| |||||
10°F (10°C), lbs. (kg) |
|
|
|
|
|
|
|
|
| MED | N/A | N/A | 2.40 | 4.4 | 4.65 | 5.17 | |
|
| |||||||
|
| (1.09) | (2.00) | (2.11) | (2.35) | |||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| HIGH | N/A | N/A | 2.84 | 5.5 | 5.79 | 7.78 |
|
| (1.29) | (2.50) | (2.63) | (3.52) | |||
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |
Average steam use per cycle, bhp (kg) | N/A | 0.73 | 1.43 | 2.32 | 1.34 | 1.14 | ||
|
|
|
| (6.9) | (12.2) | (15.4) | (20.9) | (31.45) |
|
|
|
|
|
|
|
| |
Electrical Heating |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
Total electrical heating capacity, | Input Voltage |
|
|
|
|
| ||
kW |
|
|
|
|
|
|
|
|
| 200V | 5.4 | 5.4 | 10.8 | 10.8 | 21.7 | N/A | |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| 240V | 7.8 | 7.8 | 15.6 | 15.6 | 31.2 | N/A |
|
|
|
|
|
|
|
|
|
|
| 380V | 6.5 | 6.5 | 13.0 | 13.0 | 19.6 | 34.4 |
|
|
|
|
|
|
|
|
|
|
| 415V | 7.8 | 7.8 | 15.5 | 15.5 | 23.3 | 41 |
|
|
|
|
|
|
|
|
|
|
| 480V | 10.4 | 10.4 | 15.6 | 15.6 | 31.2 | 54.8 |
|
|
|
|
|
|
|
|
|
Electrical heating elements |
| 3 | 3 | 3 | 9 | 12 | 12 | |
|
|
|
|
|
|
|
| |
Electrical heat element size, kW |
| 2.6 | 2.6 | 5.2 | 2.6 | 2.6 | 4.2 | |
|
|
|
|
|
|
|
|
|
16 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8208301 |