Alliance Laundry Systems CHM1772C manual Centrifugal Force Data, Electrical Heating

Page 18

Specifications and Dimensions

V-Speed and F-Speed Models (Continued)

Specification

 

20

30

40

60

80

125

 

 

 

 

 

 

 

 

Cylinder Speeds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gentle wash/reverse speed, RPM

 

29

27

26

26

22

26

 

 

 

 

 

 

 

 

Wash/reverse speed, RPM

 

52

52

46

43

40

37

 

 

 

 

 

 

 

 

Distribution speed, RPM

 

92

92

82

77

70

65

 

 

 

 

 

 

 

 

Low extract speed, RPM

 

366

366

328

307

280

260

 

 

 

 

 

 

 

Medium extract speed, RPM (Not

534

534

478

447

408

378

available on Electronic Control models)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High extract speed, RPM

 

686

686

613

574

524

485

 

 

 

 

 

 

 

 

Centrifugal Force Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gentle wash centrifugal force, G

 

0.25

0.25

0.25

0.25

0.25

0.43

 

 

 

 

 

 

 

 

Wash/reverse centrifugal force, G

 

0.8

0.8

0.8

0.8

0.8

0.8

 

 

 

 

 

 

 

 

Distribution centrifugal force, G

 

2.5

2.5

2.5

2.5

2.5

2.6

 

 

 

 

 

 

 

 

Extract Speed 1

 

60

60

60

60

60

60

 

 

 

 

 

 

 

 

Extract Speed 2

 

80

80

80

80

80

80

 

 

 

 

 

 

 

 

Extract Speed 3

 

100

100

100

100

100

100

 

 

 

 

 

 

 

Extract Speed 4 (V-Speed only), G

120

120

120

120

120

120

 

 

 

 

 

 

 

Extract Speed 5 (V-Speed only), G

140

140

140

140

140

140

 

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam inlet connection size, NPT

 

N/A

N/A

1/2

1/2

1/2

3/4

 

 

 

 

 

 

 

 

Number of steam inlets

 

N/A

N/A

1

1

1

1

 

 

 

 

 

 

 

 

Steam required to raise bath

 

LOW

N/A

N/A

2.09

3.6

2.58

3.64

water temperature

 

(0.94)

(1.63)

(1.17)

(1.65)

 

 

 

 

10°F (10°C), lbs. (kg)

 

 

 

 

 

 

 

 

 

MED

N/A

N/A

2.40

4.4

4.65

5.17

 

 

 

 

(1.09)

(2.00)

(2.11)

(2.35)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

N/A

N/A

2.84

5.5

5.79

7.78

 

 

(1.29)

(2.50)

(2.63)

(3.52)

 

 

 

 

 

 

 

 

 

 

 

 

 

Average steam use per cycle, bhp (kg)

N/A

0.73

1.43

2.32

1.34

1.14

 

 

 

 

(6.9)

(12.2)

(15.4)

(20.9)

(31.45)

 

 

 

 

 

 

 

 

Electrical Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total electrical heating capacity,

Input Voltage

 

 

 

 

 

kW

 

 

 

 

 

 

 

 

 

200V

5.4

5.4

10.8

10.8

21.7

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

240V

7.8

7.8

15.6

15.6

31.2

N/A

 

 

 

 

 

 

 

 

 

 

 

380V

6.5

6.5

13.0

13.0

19.6

34.4

 

 

 

 

 

 

 

 

 

 

 

415V

7.8

7.8

15.5

15.5

23.3

41

 

 

 

 

 

 

 

 

 

 

 

480V

10.4

10.4

15.6

15.6

31.2

54.8

 

 

 

 

 

 

 

 

 

Electrical heating elements

 

3

3

3

9

12

12

 

 

 

 

 

 

 

 

Electrical heat element size, kW

 

2.6

2.6

5.2

2.6

2.6

4.2

 

 

 

 

 

 

 

 

 

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208301

Image 18
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Do not bypass any safety devices in the machineModel Identification ModelIntroduction Pound 125Delivery Inspection Nameplate LocationCN040GC2OUID01 Introduction Model Number Familiarization GuideReplacement Parts Customer ServiceSpeed Models Specification Weight and Shipping Information Wash Cylinder InformationDrive Train Information Power ConsumptionEstimated Building Heat Load Cylinder SpeedsElectrical Heating Optional Number of motors in drive train Drive motor power, hp kW Electrical Heating Specifications and Dimensions Specifications and Dimensions Machine Capacity Dimensions 92 in 252 mm 94 in 202 mm Dimensional Clearances Machine Capacity Dimensional Clearances Dimensions 125Machine Foundation Minimum Depth Methods RequirementMinimum Floor Load Data, 2 Speed Models Specification Floor Load Data, Variable-Speed Models Specification 125Concrete Foundation Installation 20, 30, 40 and 60 ModelsInstallation Models Machine Anchoring Direct-to-Finished-Floor InstallationAnchor Specifications Refer to Figure Ft.- lbsElevated Base Frame Installation Completed expansion bolt installation is shown in FigureP035I Mounting Bolt Hole Locations Without Elevated Base Frames ModelsFront of Frame 19 mm 45 mm 660 mm 32 mm 41.5 1054 mm 1219 mm Mounting Bolt Hole Locations With Elevated Base Frames CHM2072N 92 mm 56 mm Drain Connection Drain TroughDrain Information 125 Drain Line Sizing Minimum Drain ID Model Number of MachinesNumber Supply Line Size Machines Water Connection RequirementsCabinet Hardmount Water Supply Information Hot/ColdElectrical Installation Requirements Input Power Conditioning Input Power Condition Corrective ActionCircuit Breakers and Quick Disconnects Connection SpecificationsInput Voltage Requirements GroundingPhase Adder Thermal Overload ProtectorInstallation Electrical Specifications Pound Capacity Models Standard Electric Heat380 440 200 208 Variable-Speed Models 380-415 440-480 200 208-240 10.0 380 50/60 10.0 Steam Supply Information Steam Requirements Steam Heat Option OnlySupply Dispensing Supply DispensingExternal Supplies Connection of External Liquid Supplies 20 80 Pound OPL ModelsStart Up Basket Rotation