Installation
Steam Requirements (Steam Heat Option Only)
WARNING
Hot Surfaces. Will cause severe burns. Turn steam off and allow steam pipes, connections and components to cool before touching.
W505
For machines equipped with optional steam heat, install piping in accordance with approved commercial steam practices. Steam requirements are shown in Table 16.
Steam Supply Information
Steam inlet |
| 40 – 80 pound | 1/2 in. (13 mm) |
connection size |
|
|
|
| 125 pound | 3/4 in. (19 mm) | |
|
| ||
|
|
|
|
Number of steam inlets |
| 1 | |
|
|
| |
Recommended pressure |
| 30 – 80 psi | |
|
|
| (2.0 – 5.4 bar) |
|
|
| |
Maximum pressure |
| 80 psi | |
|
|
| (5.4 bar) |
|
|
|
|
|
| Table 16 |
|
IMPORTANT: Failure to install the customer supplied steam filter may void the warranty.
Supply Dispensing
WARNING
Dangerous Chemicals. May damage eyes and skin. Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals. Ensure an
|
| W363 |
|
| |
|
|
|
Supply Dispensing |
| |
|
|
|
Capacities | 20 – 80 | 125 |
|
|
|
Number of supply | 4 | 0 or 5 |
compartments |
| (optional) |
|
|
|
Number of external |
|
|
liquid supply | 5 | 5 |
connections (OPL only) |
|
|
Liquid supply | 3/8 in. | 5/8 in. |
connection size | (8 mm) | (15.9 mm) |
|
|
|
Table 17
IMPORTANT: Undiluted chemical dripping can damage the machine. All chemical injection supply dispenser pumps and dispenser tubing should be mounted below the washer’s injection point. Loops do not prevent drips if these instructions are not followed.
IMPORTANT: Failure to follow these instructions could damage the machine and void the warranty.
52 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8208301 |