Before any deviation from specified installation procedures is attempted, the customer or installer should contact the distributor.
IMPORTANT: Increasing the drain hose length, installing elbows, or causing bends will decrease drain flow rates and increase drain times, impairing machine performance.
Installation
Refer to Table 5 for capacity-specific drain information.
NOTE: Installation of additional machines will require larger drain connections. Refer to Table 6.
Drain Information
| 20 | 30 | 40 | 60 | 80 | 125 |
|
|
|
|
|
|
|
Drain connection size, | 2 in. | 2 in. | 3 in.* | 3 in.* | 3 in.* | 3.5 in.* |
OD | (51 mm) | (51 mm) | (76 mm) | (76 mm) | (76 mm) | (89 mm) |
|
|
|
|
|
|
|
Number of drain outlets | 1 | 1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
Drain flow capacity | 20 gal/min | 25 gal/min | 45 gal/min | 55 gal/min | 50 gal/min | 70 gal/min |
| (76 l/min) | (95 l/min) | (170 l/min) | (208 l/min) | (189 l/min) | (265 l/min) |
|
|
|
|
|
|
|
Recommended | 1.8 ft.3 | 2.5 ft.3 | 4.52 ft.3 | 4.52 ft.3 | 5.9 ft.3 | 13 ft3 |
drain pit size | (51 l) | (71 l) | (128 l) | (128 l) | (167 l) | (368 l) |
|
|
|
|
|
|
|
*Also works with 3 in. OD PVC pipe if connected to inside of drain tee connector.
Table 5
Drain Line Sizing
Minimum Drain ID
Model |
|
| Number of Machines |
|
| ||
|
|
|
|
|
|
| |
1 | 2 |
| 3 |
| 4 | 5 | |
|
|
| |||||
|
|
|
|
|
|
|
|
20 | 2 in. (51 mm) | 3 in. (76 mm) |
| 3 in. (76 mm) |
| 4 in. (102 mm) | 4 in. (102 mm) |
|
|
|
|
|
|
|
|
30 | 2 in. (51 mm) | 3 in. (76 mm) |
| 3 in. (76 mm) |
| 4 in. (102 mm) | 4 in. (102 mm) |
|
|
|
|
|
|
|
|
40 | 3 in. (76 mm) | 4 in. (102 mm) |
| 4 in. (102 mm) |
| 4 in. (102 mm) | 6 in. (152 mm) |
|
|
|
|
|
|
|
|
60 | 3 in. (76 mm) | 4 in. (102 mm) |
| 4 in. (102 mm) |
| 4 in. (102 mm) | 6 in. (152 mm) |
|
|
|
|
|
|
|
|
80, 125 | 4 in. (102 mm) | 6 in. (152 mm) |
| 6 in. (152 mm) |
| 8 in. (203 mm) | 8 in. (203 mm) |
|
|
|
|
|
|
|
|
Table 6
F8208301 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 41 |