Installation
CAUTION
Do not attempt to increase fuse rating or alter wiring of external chemical supply terminal strip in such as way that may conflict with the suggested methods provided on the Optional External Supply Wiring Diagram.
W699
Connection of External Liquid Supplies
20 – 80 Pound OPL Models
1.Facing the rear of the machine, locate the five 3/8 inch supply hose connections found on the
|
| |
| C VALVE PANEL – REAR VIEW | 1 |
| CHM2237N | |
|
| CHM2237N |
1 | External Supply Hose Opening |
|
Figure 29
2.Drill through the five plastic holes on the valve panel for the external supply hoses as needed.
3.Remove plastic debris.
4.Attach the external supply hoses to the ports at each of the drilled holes.
5.Secure with proper clamps.
NOTE: Do not attempt to make chemical injection supply pump electrical connections to points other than those provided specifically for that purpose by the factory.
Consult the supply vendor instructions for operational details about supply injections.
125 Pound OPL Models
(With Optional Dispenser)
Refer to Figure 30.
1.Remove plugs from base. Plugs are assembled inside tubing ring.
2.Install strain reliefs with the seal nuts.
3.Insert tubes through base. Do not remove dry supply cups. Tube should extend into plastic cup, with exception of softener tube, which should be routed to outside of cup.
4.Tighten seal nut to prevent tubing from escaping assembly.
IMPORTANT: Increasing fuse rating may cause damage to
IMPORTANT: Any injection system pump that requires anything other than 24VAC must be powered by a separate external power source.
Consult chemical injection supply system instructions for operational details.
1
2
3
4
5
PHM2001N
CHM2001N
1Strain Relief for Liquid Chemical Supply Lines
2Supply Dispenser Lid
3Four Way Water Valve
4Dry Supply Cups
5Supply Dispenser
Figure 30