Alliance Laundry Systems CHM1772C manual Machine Foundation, Minimum Depth Methods Requirement

Page 24

Installation

Machine Foundation

NOTE: Do not mount on wooden floors, tile floors, above ground level, or over basements or crawl spaces because of the high extract speed and the G-forces exerted.

Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during the extract cycle.

The floor and foundation must be minimum 4000 psi reinforced concrete set firmly in clean, compacted fill dirt.

The machine must be anchored to a smooth, level surface so that the entire base of the machine is supported and rests on the mounting surface. (Do not support the machine on only four points.)

Grouting is required.

An elevated foundation must not exceed 8 inches (203 mm).

Refer to Table 1 for foundation and anchoring requirements.

Machine Foundation Requirements

 

 

Foundation

Mounting

Installation

Anchoring

Anchoring

Models

Bolt

Thickness

Bolt

Foundation

Method(s)

Diameter

 

 

(minimum)

depth

Method(s)

Requirement*

Size

 

 

 

 

 

 

(minimum)

2 Speed and F-Speed

4 in.

2.75 in.

Direct-to-floor, elevated

Expansion bolt

5/8 in.

(20-60 Models)

(102 mm)

(70 mm)

base frame, or concrete

or Epoxy bolt

 

 

 

 

 

foundation

 

 

 

 

 

 

 

 

Variable-Speed

6 in.

2.75 in.

Direct-to-floor, elevated

Epoxy bolt

5/8 in.

(20-60 Models)

(152 mm)

(70 mm)

base frame or concrete

 

 

 

 

 

 

foundation

 

 

 

 

 

 

 

 

 

 

80 Models

9 in.

3.25 in.

Direct-to-floor or

Epoxy bolt or

3/4 in.

Variable-

(229 mm)

(83 mm)

concrete foundation

rebar frame

 

 

 

Speed

 

 

 

 

 

 

125 Models

12 in.

3.25 in.

 

 

 

 

 

 

 

 

(304 mm)

(83 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Recommend SAE 495 Grade 5 or higher strength bolts.

Table 1

WARNING

To reduce the risk of fire, this appliance must be bolted to an uncovered concrete floor.

W731

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208301

Image 24
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Do not bypass any safety devices in the machineModel Identification ModelIntroduction Pound 125Delivery Inspection Nameplate LocationCN040GC2OUID01 Introduction Model Number Familiarization GuideReplacement Parts Customer ServiceSpeed Models Specification Weight and Shipping Information Wash Cylinder InformationPower Consumption Estimated Building Heat LoadDrive Train Information Cylinder SpeedsElectrical Heating Optional Number of motors in drive train Drive motor power, hp kW Electrical Heating Specifications and Dimensions Specifications and Dimensions Machine Capacity Dimensions 92 in 252 mm 94 in 202 mm Dimensional Clearances Machine Capacity Dimensional Clearances Dimensions 125Machine Foundation Minimum Depth Methods RequirementMinimum Floor Load Data, 2 Speed Models Specification Floor Load Data, Variable-Speed Models Specification 125Concrete Foundation Installation 20, 30, 40 and 60 ModelsInstallation Models Direct-to-Finished-Floor Installation Anchor Specifications Refer to FigureMachine Anchoring Ft.- lbsElevated Base Frame Installation Completed expansion bolt installation is shown in FigureP035I Mounting Bolt Hole Locations Without Elevated Base Frames ModelsFront of Frame 19 mm 45 mm 660 mm 32 mm 41.5 1054 mm 1219 mm Mounting Bolt Hole Locations With Elevated Base Frames CHM2072N 92 mm 56 mm Drain Connection Drain TroughDrain Information 125 Drain Line Sizing Minimum Drain ID Model Number of MachinesWater Connection Requirements Cabinet Hardmount Water Supply InformationNumber Supply Line Size Machines Hot/ColdElectrical Installation Requirements Input Power Conditioning Input Power Condition Corrective ActionConnection Specifications Input Voltage RequirementsCircuit Breakers and Quick Disconnects GroundingPhase Adder Thermal Overload ProtectorInstallation Electrical Specifications Pound Capacity Models Standard Electric Heat380 440 200 208 Variable-Speed Models 380-415 440-480 200 208-240 10.0 380 50/60 10.0 Steam Requirements Steam Heat Option Only Supply DispensingSteam Supply Information Supply DispensingExternal Supplies Connection of External Liquid Supplies 20 80 Pound OPL ModelsStart Up Basket Rotation