Specifications and Dimensions
2 Speed Models (Continued)
Specification |
|
| 20 | 30 | 40 | 60 |
|
|
|
|
|
| |
Direct Steam Heating (Optional) |
|
|
|
| ||
|
|
|
|
| ||
Steam inlet connection size, NPT |
| N/A | N/A | 1/2 | 1/2 | |
|
|
|
|
|
|
|
Number of steam inlets |
|
| N/A | N/A | 1 | 1 |
|
|
|
|
|
|
|
Steam required to raise bath | LOW |
| N/A | N/A | 2.09 | 3.6 |
water temperature, |
| (0.84) | (0.895) | |||
|
|
|
| |||
10°F (10°C), lbs. (kg) |
|
|
|
|
|
|
MED |
| N/A | N/A | 2.40 | 4.4 | |
|
| |||||
|
|
| (1.15) | (1.384) | ||
|
|
|
|
| ||
|
|
|
|
|
|
|
| HIGH |
| N/A | N/A | 2.84 | 5.5 |
|
|
| (1.48) | (1.916) | ||
|
|
|
|
| ||
|
|
|
|
|
|
|
Average steam use per cycle, |
|
| N/A | 0.73 | 1.43 | 2.32 |
bhp (kg) |
|
| (6.9) | (12.2) | (15.4) | |
|
|
| ||||
|
|
|
|
|
| |
Electrical Heating (Optional) |
|
|
|
| ||
|
|
|
|
|
|
|
Total electrical heating | Input Voltage |
|
|
|
| |
capacity, kW |
|
|
|
|
|
|
200V |
| 5.4 | 5.4 | 10.8 | 10.8 | |
|
| |||||
|
|
|
|
|
|
|
| 240V |
| 7.8 | 7.8 | 15.6 | 15.6 |
|
|
|
|
|
|
|
| 380V |
| 6.5 | 6.5 | 13.0 | 13.0 |
|
|
|
|
|
|
|
| 415V |
| 7.8 | 7.8 | 15.5 | 15.5 |
|
|
|
|
|
|
|
| 480V |
| 10.4 | 10.4 | 15.6 | 15.6 |
|
|
|
|
|
|
|
Electrical heating elements |
|
| 3 | 3 | 6 | 6 |
|
|
|
|
|
| |
Electrical heat element size, kW |
| 2.6 | 2.6 | 2.6 | 2.6 | |
|
|
|
|
|
|
|
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8208301 |