Installation
Refer to Table 2 and Table 3 for static and dynamic loads on the floor or foundation.
Floor Load Data, 2 Speed Models
Specification | 20 | 30 | 40 | 60 |
|
|
|
|
|
Static floor load, lbs. (kN) | 449 | 622 | 903 | 1099 |
| (1.99) | (2.76) | (4.0) | (4.9) |
|
|
|
|
|
Static pressure, | 97.8 | 101 | 118 | 120 |
| (4.68) | (4.84) | (5.65) | (5.75) |
|
|
|
|
|
Dynamic load, lbs. (kN) | 374 | 495 | 898 | 1404 |
| (1.66) | (2.2) | (3.99) | (6.3) |
|
|
|
|
|
Dynamic pressure, | 165.3 | 169 | 216 | 253 |
(7.91) | (8.09) | (10.3) | (12.11) | |
Dynamic load frequency, Hz | 8.8 | 7.7 | 8.2 | 7.8 |
|
|
|
|
|
Maximum moment about | 714 | 989 | 1926 | 3086 |
machine base, | (0.97) | (1.34) | (2.61) | (4.2) |
|
|
|
|
|
Maximum vertical load, lbs. (kN) | 759 | 1038 | 1653 | 2322 |
| (3.37) | (4.62) | (7.4) | (10.3) |
|
|
|
|
|
Table 2
Floor Load Data, Variable-Speed Models
Specification | 20 | 30 | 40 | 60 | 80 | 125 |
|
|
|
|
|
|
|
Static floor load, lbs. (kN) | 482 | 624 | 923 | 1061 | 1738 | 2839 |
| (2.14) | (2.78) | (4.11) | (4.22) | (7.73) | (12.6) |
|
|
|
|
|
|
|
Static pressure, | 105 | 102 | 121 | 116 | 126.9 | 177.5 |
| (5.02) | (4.87) | (5.78) | (5.54) | (6.07) | (8.5) |
|
|
|
|
|
|
|
Dynamic load, lbs. (kN) | 532 | 767 | 1049 | 1514 | 3310 | 4364 |
| (2.37) | (3.41) | (4.67) | (6.73) | (14.72) | (19.4) |
|
|
|
|
|
|
|
Dynamic pressure, | 207 | 214 | 238 | 261 | 350.5 | 431.5 |
(9.98) | (10.22) | (11.37) | (12.47) | (16.78) | (20.6) | |
Dynamic load frequency, Hz | 11.5 | 10.7 | 10.2 | 9.6 | 8.95 | 8.1 |
|
|
|
|
|
|
|
Maximum moment about | 1016 | 1535 | 2252 | 3328 | 8482 | 14547 |
machine base, | (1.38) | (2.08) | (3.05) | (4.51) | (11.5) | (19.7) |
|
|
|
|
|
|
|
Maximum vertical load, lbs. (kN) | 950 | 1313 | 1824 | 2394 | 4799 | 6904 |
| (4.23) | (5.84) | (8.11) | (10.65) | (21.35) | (30.7) |
|
|
|
|
|
|
|
Table 3
F8208301 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 23 |