Machine Anchoring

Before anchoring the machine, refer to Table 1 to determine the appropriate method of anchoring for the machine.

NOTE: Improper installation may void the warranty. Consult the manufacturer or distributor before varying from a procedure.

Direct-to-Finished-Floor Installation

Installing With Expansion Bolts for 2 Speed Models

NOTE: Expansion bolts are not suitable for variable-speed machine installations.

1.Verify the floor meets the requirements given in the Machine Foundation section.

2.Mounting surface should be level and machine must be properly grouted.

3.Use the base of the machine as a template by positioning the machine in the desired location and marking the pre-drilled mounting holes on the floor. Mounting Bolt templates are available through Alliance Laundry Systems.

4.Refer to Figure 9 and Table 4 to set the drill depth gauge.

5.Drill the holes to the set depth. Refer to Table 4.

6.Use compressed air or a squeeze bulb to clean out debris from each hole.

7.Fill half the hole depth with an industry-accepted adhesive anchoring system.

8.Insert expansion bolt until it reaches the bottom of the hole and 1.5 inches (38 mm) of the bolt extends above the surface.

9.Allow adhesive around bolt to cure properly.

NOTE: Select the proper size and strength anchor system. Follow the manufacturer’s installation instructions and recommended cure times.

10.Position machine over anchoring bolts.

11.Raise and level the machine .5 inch (13 mm) off the floor on three points, using spacers such as nut fasteners.

12.Fill the space between the machine base and the floor with a good quality non-shrinking machinery grout to ensure a stable installation. Grout completely under all frame members.

Installation

13.Position washers and nuts on bolts and finger tighten nuts to machine base.

14.Before grout sets completely, make a drain opening in the grouting at the rear center of the machine with a stiff piece of wire. This opening should be approximately .5 inch (13 mm) wide to allow any surface water build-up under the base of the machine to drain away. Do not omit this step.

15.Allow machine grout to set, but not cure.

16.Remove the spacers carefully, allowing the machine to settle into the grout.

17.Tighten the nuts by even increments – one after the other using the specified torque – until all are tightened evenly and the machine is fastened securely to the floor. Refer to Table 4.

A

B

C

CHM

CHM2285N

Figure 9

 

Anchor Specifications

 

 

(refer to Figure 9)

 

Torque

 

 

 

 

 

 

 

 

 

 

(ft.- lbs.)

Models

A

B

 

C

 

 

(minimum)

 

 

 

 

 

 

 

 

 

 

 

 

 

20-60

5/8 in.

2.75 in.

 

.625 in.

90

(69.9 mm)

 

(15.9 mm)

(ft.-lbs.)

 

 

 

 

 

 

 

 

 

80-125

3/4 in.

3.25 in.

 

.75 in.

175

(82.6 mm)

 

(19 mm)

(ft.-lbs.)

 

 

 

 

 

 

 

 

 

Table 4

F8208301

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

27

Image 29
Contents Washer-Extractors Page Contents Important Safety Instructions Explanation of Safety MessagesSafety Information Safety Decals Do not bypass any safety devices in the machine Operator SafetyModel Model IdentificationIntroduction 125 PoundNameplate Location Delivery InspectionIntroduction Model Number Familiarization Guide CN040GC2OUID01Customer Service Replacement PartsWash Cylinder Information Speed Models Specification Weight and Shipping InformationEstimated Building Heat Load Power ConsumptionDrive Train Information Cylinder SpeedsElectrical Heating Optional Number of motors in drive train Drive motor power, hp kW Electrical Heating Specifications and Dimensions Specifications and Dimensions Machine Capacity Dimensions 92 in 252 mm 94 in 202 mm Machine Capacity Dimensional Clearances Dimensions 125 Dimensional ClearancesMinimum Machine FoundationMinimum Depth Methods Requirement Floor Load Data, Variable-Speed Models Specification 125 Floor Load Data, 2 Speed Models Specification20, 30, 40 and 60 Models Concrete Foundation InstallationInstallation Models Anchor Specifications Refer to Figure Direct-to-Finished-Floor InstallationMachine Anchoring Ft.- lbsCompleted expansion bolt installation is shown in Figure Elevated Base Frame InstallationP035I Models Mounting Bolt Hole Locations Without Elevated Base FramesFront of Frame 19 mm 45 mm 660 mm 32 mm 41.5 1054 mm 1219 mm Mounting Bolt Hole Locations With Elevated Base Frames CHM2072N 92 mm 56 mm Drain Trough Drain ConnectionDrain Line Sizing Minimum Drain ID Model Number of Machines Drain Information 125Cabinet Hardmount Water Supply Information Water Connection RequirementsNumber Supply Line Size Machines Hot/ColdElectrical Installation Requirements Input Power Condition Corrective Action Input Power ConditioningInput Voltage Requirements Connection SpecificationsCircuit Breakers and Quick Disconnects GroundingThermal Overload Protector Phase AdderStandard Electric Heat Installation Electrical Specifications Pound Capacity Models380 440 200 208 Variable-Speed Models 380-415 440-480 200 208-240 10.0 380 50/60 10.0 Supply Dispensing Steam Requirements Steam Heat Option OnlySteam Supply Information Supply DispensingExternal Supplies 20 80 Pound OPL Models Connection of External Liquid SuppliesBasket Rotation Start Up