Input Voltage Requirements
For voltages above or below listed specifications, contact your power company or local electrician.
If machine is intended for
If a delta supply system is used on a
IMPORTANT: Improper connections will result in equipment damage and will void warranty.
DANGER
Never touch terminals or components of the AC inverter drive unless power is disconnected for three minutes.
W737
DANGER
Hazardous Rotation Speed. Will cause serious injury when controlling AC inverter drive with a parameter unit, safey features are bypassed allowing basket to rotate at high speeds with the door open. Place large sign on front of machine to warn people of imminent danger.
W361
Circuit Breakers and Quick Disconnects
IMPORTANT: All quick disconnects should comply with the above specifications. DO NOT use fuses instead of circuit breakers.
Installation
Connection Specifications
IMPORTANT: Connection must be made by a qualified electrician using wiring diagram provided with machine, or according to accepted European standards for
Connect machine to an individual branch circuit not shared with lighting or other equipment. Shield connection in a
Use wire sizes indicated in the Electrical Specifications chart for runs up to 50 feet (15 m). Use next larger size for runs of 50 to 100 feet (15 to 30 m). Use two sizes larger for runs greater than 100 feet (30 m).
Grounding
For personal safety and proper operation, the machine must be grounded in accordance with state and local codes. If such codes are not available, grounding must conform to the National Electric Code, article 250 (current edition). The ground connection must be made to a proven earth ground, not to conduit or water pipes.
WARNING
Electrically heated machines DO NOT require dual power sources. Do not connect customer power or customer load to the Internal Load Distribution terminal block. Refer to the machine electrical schematic for details.
W759
F8208301 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 45 |