Installation

The completed expansion bolt installation is shown in Figure 10.

NOTE: Check and retighten the nuts after five to ten days of operation and every three months thereafter.

2

1

1.5 in.

(38.1 mm)

Refer to

Table 4

3 4

5

6 CHM2284

CHM2284N

1Washer

2Locknut

3Machine Base or Base Frame

4Machinery Grout

5Adhesive

6Expansion Bolt

Figure 11

Figure 10

Installing With Elevated Base Frame

Elevated Base Frame Installation

Factory-built elevated steel base frames are designed to meet the specifications of the 20-60 2 speed, F-speed and V-speed model washer-extractors only. Refer to Figure 11. The spacing between two machines provided by an elevated base is .38 inch (9.5 mm) in 20, 30 and 60 pound models and .25 inch

1.Verify the floor meets the requirements given in the Machine Foundation section.

2.Use the elevated base frame as a template by positioning the frame in the desired location and marking the pre-drilled mounting holes on the floor.

(6.3 mm) in 40 pound models.

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208301

Image 30
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Do not bypass any safety devices in the machineModel Identification ModelIntroduction Pound 125Delivery Inspection Nameplate LocationCN040GC2OUID01 Introduction Model Number Familiarization GuideReplacement Parts Customer ServiceSpeed Models Specification Weight and Shipping Information Wash Cylinder InformationDrive Train Information Power ConsumptionEstimated Building Heat Load Cylinder SpeedsElectrical Heating Optional Number of motors in drive train Drive motor power, hp kW Electrical Heating Specifications and Dimensions Specifications and Dimensions Machine Capacity Dimensions 92 in 252 mm 94 in 202 mm Dimensional Clearances Machine Capacity Dimensional Clearances Dimensions 125Machine Foundation Minimum Depth Methods RequirementMinimum Floor Load Data, 2 Speed Models Specification Floor Load Data, Variable-Speed Models Specification 125Concrete Foundation Installation 20, 30, 40 and 60 ModelsInstallation Models Machine Anchoring Direct-to-Finished-Floor InstallationAnchor Specifications Refer to Figure Ft.- lbsElevated Base Frame Installation Completed expansion bolt installation is shown in FigureP035I Mounting Bolt Hole Locations Without Elevated Base Frames ModelsFront of Frame 19 mm 45 mm 660 mm 32 mm 41.5 1054 mm 1219 mm Mounting Bolt Hole Locations With Elevated Base Frames CHM2072N 92 mm 56 mm Drain Connection Drain TroughDrain Information 125 Drain Line Sizing Minimum Drain ID Model Number of MachinesNumber Supply Line Size Machines Water Connection RequirementsCabinet Hardmount Water Supply Information Hot/ColdElectrical Installation Requirements Input Power Conditioning Input Power Condition Corrective ActionCircuit Breakers and Quick Disconnects Connection SpecificationsInput Voltage Requirements GroundingPhase Adder Thermal Overload ProtectorInstallation Electrical Specifications Pound Capacity Models Standard Electric Heat380 440 200 208 Variable-Speed Models 380-415 440-480 200 208-240 10.0 380 50/60 10.0 Steam Supply Information Steam Requirements Steam Heat Option OnlySupply Dispensing Supply DispensingExternal Supplies Connection of External Liquid Supplies 20 80 Pound OPL ModelsStart Up Basket Rotation