7. GARDEN EXAMPLE
Proposals for installation and settings
Area: 3500 m2.
Timer: Operating time of 17 hours per day.
Exit angles: 90° - 270°.
Follow loop out: Direction Guide 1, Distance 25 metres and Proportion 30 %.
Search method: Irregular and Follow guide wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes and boundary wire 99 minutes. Automower® is never permitted to follow the boundary wire.
Corridor width: Guide 1 6
Area: 6000 m2. Rectangular garden with the charging station placed by an island. A large part of the boundary wire is routed on a slope that is steeper than 10 %. Guide wire recommended.
Timer: Operating time of 24 hours per day.
Exit angles: 90° - 270°.
Search method: Irregular and Follow guide wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes and boundary wire 99 minutes. Automower® is never permitted to follow the boundary wire.
Corridor width: 19
Area: 3000 m2. There is a number of islands.
No guide wire is required.
Timer: Operating time of 15 hours per day.
Exit angles: 90°- 270°.
Search method: Irregular.
Delay: Guide 1 2 minutes, Guide 2 2 minutes and boundary wire 11 minutes.
Corridor width: Boundary wire 10
English - 63