Frymaster H50 Series manuals
Kitchen Appliance > Fryer
When we buy new device such as Frymaster H50 Series we often through away most of the documentation but the warranty.
Very often issues with Frymaster H50 Series begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Fryer Frymaster H50 Series is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Fryer on our side using links below.
Frymaster H50 Series Manual
138 pages 10.26 Mb
7 CHAPTER 1: SERVICE PROCEDURES 10 1-4 CURRENT FLOW THROUGH INTERFACE BOARDS 806-3398 AND 106-0386 (H50 APPLICATION) LEFT VAT FULL OR RIGHT VAT INTERFACE BOARD** Dual Vat configurations ** Full Vat configurations 12 Honeywell13 1-7 CE Standard Burner Manifold Gas Pressures for Fryers Manufactured After April 1999 CE Standard Burner Manifold Gas Pressures for Fryers Manufactured Through April 1999 Gas Pre ssu re Natur al 3" W.C. 0.73 kPa Propane 8.25" W.C. 2.5 kPa Non-CE Standard Burn er Ma ni fol d Ga s P r essu re s correct pressure. Non-CE Valve Earlier Model CE Valve Later Model CE Valve GAS VALVE REGULATOR CAP 18 24 Disassembling A Frypot(Full Vat Illustrated) 25 Re-assembling A Frypot(Full Vat Illustrated)40 1-34 PWR FULL OR RIGHT VATV2D PWR V1S (FV) OR V1D (DV) J1 PIN 9 J3 PIN 9 FV = Full Vat DV = Dual Vat 41 1-35 24 VOLT CIRCUIT With Interface Board 806-3398 or 106-0386 and One 807-3366 (FV) Ignition ModuleJ3 PIN 9 Jumper J3 PIN 9NOTE: Some units may be wired in this manner. V1S PWR (left side) V2S PWR (right side) V1D J3 PIN 8 1-38 1.9 Simplified Wiring Diagrams BUILT-IN FILTRATION (TWO RELAYS: K2 (HEAT) & K4 (BLOWER) AND TWO IGNITION MODULES)MODULE LEFT IGNITION RIGHT IGNITION MODULE LINE VOLTAGE 44 H50 SERIES FULL-VAT JUNE 1996 - JULY 1999DRAIN SAFETY SWITCH ONLY ON MODELS WITH AIR SWITCH ONLY ON CE AND SOME EXPORT UNITS 45 H50 SERIES FULL-VAT BEFORE JUNE 1996 & AFTER JULY 1999 BUILT-IN FILTRATION (ONE DUAL FUNCTION HEAT/BLOWER RELAY (K3) AND TWO IGNITION MODULES) 1-39 MODULE LINE VOLTAGE DRAIN SAFETY SWITCH ONLY ON MODELS WITH AIR SWITCH ONLY ON CE AND SOME EXPORT UNITS BUILT-IN FILTRATIONBE EQUIPPED WITH TWO MODULE. OTHERS MAY DUAL-SPARK IGNITION EQUIPPED WITH ONE AUGUST 2000 ARE MANUFACTURED AFTER NOTE: SOME UNITS IGNITION DUAL-SPARK 46 H50 SERIES FULL-VAT WITH ONE DUAL-SPARK IGNITION MODULE1-40 (ONE DUAL FUNCTION HEAT/BLOWER RELAY (K3))LINE VOLTAGE MODULE MODULES. DRAIN SAFETY SWITCH ONLY ON MODELS WITH AIR SWITCH ONLY ON CE AND SOME EXPORT UNITS 47 H50 SERIES DUAL-VAT JUNE 1996 - JULY 1999 EXPORT UNITS BUILT-IN FILTRATION (THREE RELAYS: K1 & K2 (HEAT) AND K4 (BLOWER)) 1-41 DRAIN SAFETY SWITCH ONLY ON MODELS WITH AIR SWITCH ONLY ON CE AND SOME (TWO DUAL-FUNCTION HEAT/BLOWER RELAYS (K1 & K2) EXPORT UNITS BUILT-IN FILTRATION 48 H50 SERIES DUAL-VAT BEFORE JUNE 1996 & AFTER JULY 1999LEFT IGNITION 1-42 DRAIN SAFETY SWITCH ONLY ON MODELS WITH AIR SWITCH ONLY ON CE AND SOME 49 1-43 1.10 Principal Wiring Connections C4 C1 J3 J1 LEFT VAT RIGHT OR FULL VATGND V1D PWR ALR V1S J2FILTER PAN SUCTION TUBE HEATER (BIH52 UNITS ONLY) C3 C2OIL RETURN HEATER (BIH52 UNITS ONLY) C5 C3 (CE)CABLE TO FILTER BOX 810-1062 BASKET LIFT CABLE 807-3695ON NEWER MODELS C4 HAS BEEN CHANGED TO A 12-PIN PLUG SEE PG 1-46 50 1-44 1.11 WIRING DIAGRAMS - MAIN FRYER EXTENSION TRANSFORMER REAR HEATER OIL RETURN LINE23C 25C 11C 105C 16C 17CBLOWER SWITCH REQUIRED ON EXPORT NOTE: BLOWER SWITCH IS OPTIONAL FPH150 ONLY (NON-CE) WHITE WHITE 27C 26C 18C23C 16C FALLBACK CONTROLLER8050439H22C 4C 12V 24V LOAD H50/52 SINGLE FP DV NON BL 51 1-45 53 1-47 TO J2 BLOWER AA LEFT IGNITOR RIGHT IGNITOR SOUND DEVICE 8051315C COMPUTER GROUND DETAIL AA SOUND DEVICE FULL VAT DUAL VATCOMPUTER GROUND DETAIL INSET HONG KONG UNITS ONLY FULL VATGAS VALVE TEMP PROBE HIGH LIMIT SAFETY DRAIN SWITCH DUAL VATTEMP PROBE HIGH LIMIT SAFETY DRAIN SWITCH GAS VALVE COMPUTER OR CONTROLLER 54 1-48 H50 SERIES (CE) OTHER THAN FPH150 AND MANUFACTURED GAS UNITS C1 9 8 C3 C2 14 13 12 11 8 8050526D 55 1-49 H50 SERIES MANUFACTURED GAS UNITS TROUBLE POWER FULL POT CONTROLLER THI LIMIT M 510 14 134 13 FOR FULL POT ONLY19C 18C 14C24C 86C 20C TO PIN 16 OF NEXT FRYER (16 PIN TERMINAL BLOCK) TO PIN 1 OF FILTER (16 PIN TERMINAL BLOCK) TO PIN 8 OF NEXT FRYER (16 PIN TERMINAL BLOCK) 1C 711 47 4 J2 * NOTE+ INTERFACE BOARD SHOWN SPLIT POT COMPUTER OR CONTROLLER1113 1314 1410 105 53 31 12 212 1214 1415 156 69 9NH 26C27C 46C 45C 124 3 6 5 12C 85C 86C TO PIN 13 OF FILTER (16 PIN TERMINAL BLOCK) B RIGHT IGNITOR 16C TEST SWITCH SHOWN PLAN WIRING DIAGRAM 230/24 V. H50 MANUFACTURED GAS 8050344A 56 1-50 1.12 WIRING DIAGRAMS TRANSFORMER BOXES 5 4 100 208 230 220 120 8 9 32 7 26 18050500E 120V CONFIGURATION SHOWN 26 15 76NOTE: USE TERMINALS 7 & 8 FOR 24V OUTPUT. Non-CE Transformer Boxes USE TERMINALS 11 & 12 FOR 12V OUTPUT. 123N 9 8 1 32 7 98 3 7 89 3 1 6240 1 6 VOLTS 61 2 LINECOM 14 57 1-51 58 1-52 1.13 WIRING DIAGRAMS BASKET LIFTS REFERENCES TO LEFT & RIGHT ARE FROM THE REAR OF THE FRYER Modular Basket Lift 100/120V (NOTE: There is no CE version of this option.) 59 1-53 Modular Basket Lift 208/250V (NOTE: This diagram is used for both CE and Non-CE applications.) BLUE WHITE BLACK GREEN RED ORANGE M LEFT SIDE M8050946B REFERENCES TO LEFT & RIGHT ARE FROM THE REAR OF THE FRYER 61 1-55 1.14 WIRING DIAGRAMS FILTER BOXES 8050902C FootPrint III Prior to August 1997 (NOTE: This diagram is used for both CE & Non-CE applications.) 62 1-56 Filter Magic II (NOTE: This diagram is used for both CE and Non-CE applications.) 8050503E807-2016 FILTER MAGIC MAIN POWER CABLE 1.15 WIRING DIAGRAMS OIL RETURN Oil Return/Disposal Wand Wiring (Japan/Lotteria) 2-1 64 H50 SERIES GAS FRYERS CHAPTER 2: PARTS LIST99 AB2-36 100 2-37101 2-38102 2-392.13.4 Filter Magic Oil Return Plumbing Components (Including Pump & Motors)Disconnect Components Detail of Motor, Pump, andItem shown disproportionately inch nipple (813-0117) in place of a dual vat unit, use the 3.5- NOTE: If the filter is to the left Typical Full Vat Vat Configuration Typical Dual (Split) Configurationsof the 9-inch nipple (Item 9). large for clarity. 103 2-40104 2-412.13.5 FootPrint III Filter Motors and Pump Plumbing ComponentsStandard FP III Configuration (Prior to August 1997) FPH150 Configuration Standard FP III Configuration (August 1997 and Later) 105 2-42106 2-432.13.6 FootPrint III with Power Shower Oil Return Plumbing Components FPH350 with Dual TYPICAL FOOTPRINT III OIL RETURN PLUMBING CONFIGURATIONS FPH250 Vat on Left 107 2-44108 2-452.13.7 FootPrint III with Rear Flush Oil Return Plumbing Components, StandardHanger shown cut away to reveal elbow. 109 2-46110 2-472.13.8 FootPrint III with Rear Flush Oil Return Plumbing Components, KFC 111 2-48112 2-492.13.9 FPH150-2 Oil Return Plumbingincludes Items 20-21. Control Panel Assembly 806-6358SP shown for reference. Assembly 113 2-50114 2-51115 2-52116 2-532.13.12 Oil Disposal Systems Plumbing810-0490 806-9087SP 806-9330SP Detail of Item 1 806-9109SP 117 2-54118 2-55119 2-562.13.14 Oil Disposal Wand Assembly 2.14 Frypot Assemblies and Component Parts 120 2-572.14.2 Full Vat Frypot Assembly, Component Parts See Page 2-58 for Full Vat Frypot Assembly (Typical)burners (Items 16, 18, 20, and 25). and gaskets required when replacing Kit 826-0931 contains the insulation 826-0929. can be ordered in a single kit, P/N NOTE: All insulation and gaskets 121 2-58122 2-592.14.3 Dual Vat Frypot Assembly, Component Parts See Page 2-58 for P/Nsburners (Items 13, 15, 17, and 23). and gaskets required when replacing Kit 826-0932 contains the insulation 826-0930. can be ordered in a single kit, P/N NOTE: All insulation and gaskets Dual Vat Frypot Assembly (Typical) 123 2-60124 2-612.15 Gas Supply System Assemblies and Component Parts 2.15.1 FM/MJH50 Gas Manifold AssembliesSee Page 2-63 for details of gas valve assemblies. CE FM/MJH350-4R (Typical) NON-CE FM/MJH350-4R (Typical) 125 2-62126 2-632.15.2 Gas Valves, Gas Lines and Fittings 127 2-64129 2-66130 2-672.18.2 Transformer Box ComponentsApril 2001MJ/FM/FPH350 (208-240V ) MJ/FM/FPH250 (100-120V) MJ/FM/FPH250 (208-240V) FPH150 (208-240V) FPH150 (208-240V) "Baby FootPrint" MJ/FMH150 (208-240V) MJ/FM/FPH250 RF (100-120V) MJ/FM/FPH450 (100-120V) MJ/FM/FPH450 (208-240V) MJ/FM/FPH350 (100-120V) Note: H450 went to 2-Double Boxes 131 2-68132 2-69* Not illustrated. Main Wiring Harnesses 133 Power Cords
Also you can find more Frymaster manuals or manuals for other Kitchen Appliance.