This chapter provides information about configuring the Dell PowerEdge Cluster FE100 system software.

Before configuring the cluster software, verify that your system hardware is properly cabled for clustering. See Chapter 2, “Cabling the Cluster Hardware,” in this guide for instructions on connecting the components of your PowerEdge Cluster FE100.

/RZ￿/HYHO￿6RIWZDUH￿&RQILJXUDWLRQ

Prior to installing the Microsoft Windows NT Server, Enterprise Edition operating sys- tem, you must make specific low-level software configurations to the PowerEdge Cluster FE100. Low-level software configurations are settings you make to the system before you install the operating system.

The following subsections describe how to set the low-level software to enable clustering.

+DUG￿/RRS￿,'￿IRU￿WKH￿4/RJLF￿+RVW￿%XV￿$GDSWHUV

The QLogic host bus adapters in one node must have the hard loop ID set to 125, and host bus adapters in the second node must be set to 124. The default setting for the hard loop ID on the QLogic card is 125, so you only need to change the hard loop IDs on one node.

To change the QLogic hard loop ID to 124 on one node from the default value, use the following procedure:

1.Start the node whose QLogic hard loop IDs you need to change.

2.Press <Alt><q> when the Press <Alt-Q> for Fast!UTIL message appears during the boot sequence.

3.In the Fast!UTIL utility, select the first adapter and press <Enter>.

4.Select Configuration Settings and press <Enter>.

5.Select Host Adapter Settings and press <Enter>.

6.Select Hard Loop ID and press <Enter>.

Configuring the Cluster Software

3-1

Page 39
Image 39
3Com FE100 manual RZ/HYHO6RIWZDUH&RQILJXUDWLRQ, +DUG/RRS,IRUWKH4/RJLF+RVW%XV$GDSWHUV