+LJK/HYHO6RIWZDUH&RQILJXUDWLRQ
When you have set up the internal disk drives and RAID levels, you can install and con- figure Windows NT Server, Enterprise Edition. You must set a number of operating system configurations during the installation to enable clustering. These configuration requirements are described in the Microsoft Windows NT Server, Enterprise Edition Administrator’s Guide. The following subsections briefly discuss these configurations.
,QVWDOOLQJ+32SHQ9LHZ1HWZRUN1RGH0DQDJHU
After installing the Windows NT Server, Enterprise Edition operating system and applying the Service Pack, install HP OpenView Network Node Manager (NNM) Special Edition (SE), version 1.3 or later, to the nodes. Refer to the HP OpenView Network Node Manager Special Edition User’s Guide for installation instructions.
&RQILJXULQJWKH'HOO2SHQ0DQDJH0DQDJHG1RGH $JHQWLQD&OXVWHU
Dell recommends that you only use LUN ID 7 for Data Agent communication. You can assign LUN ID 7 for the Data Agent by modifying the device list in the Agent Configu- rator using the following procedure.
NOTE: Do not assign LUN ID 7 to a disk during a binding process.
1.Open the Agent Configurator.
2.Select
This selection forces the Agent Configurator to discover the disk array.
3.Modify the Device entries so that they specify the same LUN ID 7. For example, if the following lines appear:
\\.\SCSI2:0:0:0
\\.\SCSI3:0:1:1
Change them to the following:
\\.\SCSI2:0:0:7
\\.\SCSI3:0:1:7
The last digit in the Device string indicates the LUN ID to be used for the Data Agent’s communication.
4.Save the new configuration.
Configuring the Cluster Software |