This chapter provides general troubleshooting information for the Dell PowerEdge

Cluster FE100. For troubleshooting information that is specific to the Windows NT

Server, Enterprise Edition operating system and the cluster software, refer to the

Microsoft Cluster Server Administrator’s Guide.

Table 5-1 describes problems you may encounter with your PowerEdge Cluster FE100 and the probable causes and solutions for each problem.

7DEOH￿￿￿￿￿￿￿7URXEOHVKRRWLQJ

3UREOHP

3UREDEOH￿&DXVH

&RUUHFWLYH￿$FWLRQ

 

 

 

The nodes cannot access the Dell PowerVault storage sys- tem, or the cluster software is not functioning with the stor- age system.

The PowerVault storage system is not cabled prop- erly to the nodes or the cabling between the Power- Vault components is incorrect.

The length of the interface cables exceeds the maxi- mum allowable length.

One of the cables or a media interface adapter (MIA) is faulty.

Make sure that the cables are connected properly from the node to the PowerVault storage system. Refer to the cabling instructions in “Cabling the Cluster Hard- ware” in Chapter 2 of this guide.

Ensure that copper cables do not exceed 30 meters (m) or that optical fiber cables do not exceed 500 m.

Replace the faulty cable or MIA.

The SCSI miniport device driver for the QLogic host bus adapter is not installed

Install the SCSI miniport device driver. See “SCSI Miniport Driver for the QLogic Host Bus Adapter” in Chapter 3 for instructions on installing the driver.