2-3-3. Warning Beacon Installation
A red warning beacon is electrically connected to the
case sealer, but not mounted to the machine. Install
this warning beacon on top of the frame support
member to which it is connected.
1. Remove the protective wrap from the warning
beacon and L-bracket assembly.
2. Remove the top hex-head screw from the frame
support member. Refer to Figure 2-4.
3. Secure the warning beacon L-bracket to the
frame support member with the screw just
removed.
Figure 2-4. Warning Beacon Installation
2-3-4. Pneumatic Connection
The case sealer requires a compressed air supply of
75  140 PSIG [5.2  9.5BAR] 7.0 SCFM [11.89m3/h
21oC, 101kPa] maximum at maximum cycle rate. The
optimum operating set-point on the gauge is 95  100
PSIG. As shown in Figure 2-5, an On/Off Valve, Main
Air Pressure Regulator, and Filter are provided to
service the air supply.
Connect the air supply line to the Main Air Pressure
Regulator On/Off Valve.
ü Note
The air supply On/Off Valve has provisions for
lockout/tagout according to plant regulations.
Figure 2-5. Air Supply Components
Installation 3M-Matic 800rf Case Sealer