2-12 Copyright 1999, 3M IPC. All rights reserved.
4. Check the Box Centering Pressure gauge on the
Pneumatic Control Panel. Refer to Figure 2-15.
The gauge should read 40  60 PSIG. If the
pressure does not fall within this range, adjust the
pressure regulator (CW  increases pressure,
CCW  decreases pressure).
5. Check the Side Belt Pressure gauge on the
Pneumatic Control Panel. The gauge should read
40  60 PSIG. If necessary, adjust the Side Belt
Pressure Regulator to this setting. (CW  in-
creases pressure, CCW  decreases pressure).
6. Check the Paddle Pressure gauge on the Pneu-
matic Control Panel. The gauge needle should be
at 7 PSIG. Adjust as needed.
7. Check the Counter-Balance Pressure gauge on the
Pneumatic Control Panel. The gauge should read
40  60 PSIG. If the pressure does not fall within
this range, adjust the pressure regulator (CW 
increases pressure, CCW  decreases pressure).
Figure 2-15. Pneumatic Control Panel
Installation 3M-Matic 800rf Case Sealer