5.5Defining the Rule

When defining a rule, the user must first determine the event and then which action shall result when the event happens.

5.5.1Counter Handling

Illustration 14 – Reset Values? on Page 34 shows the tab for counter handling. Depending on an event, the four counters can be Reset to their initial start value.

After being Reset, the counters will be incremented by a specified value, as seen in Chapter 5.3.2 How to Set and to Trigger Counters on Page 25.

Example 1:

If you want to start page counting after a chapter break with 2 (in order to, for example, insert a large formatted leading page at a later time) you can specify that Counter A is reset to zero and then incremented starting from two.

Example 2:

If you want to use only even numbers for page counting only, you cannot use Counter A because it is incremented automatically by 1 from the second page on. Therefore, you must disable Counter A (set its field width to zero) and use another counter for these pages (such as Counter B). Each time a level 0 (normal page) document was scanned, Counter B will be incremented by 2.