Scanner Options | Scamax 2600 / 5000 | DpuScan |
Patchcode returns these values:
0Patch T
1Patch II
2Patch III
3Patch I
4Patch IV
5Patch VI
Endorsed (0 or 1)
Note:
All
5.2.2Image Address
The image address is the part of the header that is sent to the application software with each image. From left to right, it consists of the following parts:
Fixed Text | Bytes 109 |
Counter C (Volume Counter) | Bytes 120 |
Counter B (Chapter Counter) | Bytes 131 |
Counter A (Page Counter) | Bytes 142 |
All parts have 10 digits each and are separated by a point. Numbers will be aligned to the right.
5.2.3Counters
Up to four counters can be managed. The name of the counters is based on the idea that there are many "Pages" building several "Chapters". "Chapters" build "Volumes" which will be stored on "Film Rolls".
Of course, these names should show the grouping and hierarchy only. Therefore, in another context they may be called "Document Counter", "Enclosure Counter", "File Counter", etc.
This step in the document hierarchy is called Level.
The change from one level to another will be marked either by separator sheets with printed Patchcodes, or will occur after a fixed number of pages.
Page Counter A
This counter will be incremented automatically by 1 for every scanned front side and back side of a document.
Only after an event that resets the counter can it be incremented "manually" by the
Page 19 of 42